Mechanical evaluation of fourth-generation composite femur hybrid locking plate constructs
Source abstract
Abstract
Locking compression plates are routinely used for open reduction and internal fixation of fractures. Such plates allow for locking or non-locking screw placement in each hole. A combined use of both types of screw application for stabilization of a fracture is commonly applied and referred to as hybrid internal fixation. Locking screws improve the stability of the fixation construct but at the expense of significant additional cost. This study experimentally analyzes various combinations of locking and non-locking screws under simultaneous axial and torsional loading to determine the optimal hybrid locking plate-screw construct in a fourth generation composite femur. Clinically it is necessary to ensure adequate fixation stability in a worse case fracture-bone quality scenario. A locking screw near the fracture gap increased the axial and torsional strength of the locked plate system. Greater removal torque remained in non-locked screws adjacent to locked screws compared to an all non-locking screws control group.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone fractures and treatments · Hip and Femur Fractures · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Iqbal M. Osteoporosis: epidemiology, diagnosis, and treatment. South Med J. 2000;9:2–18.
2. Miranda M. Locking plate technology and its role in osteoporotic fractures. Inj, Int J Care Inj. 2007;38S3:S35–9.10.1016/j.injury.2007.08.009 ↗
3. Luo C. Locking compression plating: a new solution for fractures in rheumatoid patients. Mod Rheumatol. 2005;15:169–72.10.1007/s10165-005-0392-z ↗
4. Miller D, Goswami T. A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing. Clin Biomech. 2007;22:1049–62.10.1016/j.clinbiomech.2007.08.004 ↗
5. Haidukewych G. Innovations in locking plate technology. J Am Acad Orthop Surg. 2004;12(4):205–12.10.5435/00124635-200407000-00001 ↗
6. Aguila AZ, Manos JM, Orlansky AS, Todhunter RJ, Trotter EJ, Van der Meulen MC. In vitro biomechanical comparison of limited contact dynamic compression plate and locking compression plate. Vet Comp Orthop Traumatol. 2005;18(4):220–6.10.1055/s-0038-1632958 ↗
7. Ahmad M, Nanda AS, Bajwa AS, Candal-Couto J, Green S, Hui AC. Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability? Injury. 2007;38:358–64.10.1016/j.injury.2006.08.058 ↗
8. Kim TUM, Ayturk A, Aiclau TH, Puttlitz CM. Fixation of osteoporotic distal fibula fractures: a biomechanical comparison of locking versus conventional plates. J Foot Ankle Surg. 2007;46(1):2–6.10.1053/j.jfas.2006.09.009 ↗
9. Uhthoff H, Poitras P, Backman D. Internal plate fixation of fractures: short history and recent developments. J Orthop Sci. 2006;11:118–26.10.1007/s00776-005-0984-7 ↗
10. Perren SM, Russenberger M, Steinmann S, Muller ME, Allgower M. A dynamic compression plate. Acta Orthopaedica Scandinavica. 1969;125(suppl):31–41.
11. Tepic S, Perren SM. The biomechanics of the PC-Fix internal fixator. Elsevier. 1995;26(Suppl 2):5–10.
12. Sommer C. Biomechanics and clinical application principles of locking plates. Suomen Ortopedia Ja Traumatologia. 2006;29:20–4.
13. Wagner, M (2003) General principles for the clinical use of the LCP. Injury 34, SB31–SB42.10.1016/j.injury.2003.09.023 ↗
14. Schandelmaier P, Stephan C, Reimers N, Krettek C. LISS osteosynthesis for distal fractures of the femur. Trauma Berufskrankh. 1999;1:392–7.10.1007/s100390050069 ↗
15. Frigg R (2003) Development of the locking compression plate. Injury 34: SB6–SB10.10.1016/j.injury.2003.09.020 ↗
16. Frigg R. Locking compression plate (LCP). An osteosynthesis plate based on the dynamic compression plate and the point contact fixator (PC-Fix). Injury. 2001;32:63–6.10.1016/S0020-1383(01)00127-9 ↗
17. Frigg R. Development of the locking compression plate. Injury. 2003;34:6–10.10.1016/j.injury.2003.09.020 ↗
18. Hou Sheng-Mou, Ching CH, Jaw LW, Chao CK, Jinn L. Mechanical tests and finite element models for bone holding power of tibial locking screws. Clin Biomech. 2004;19:738–45.10.1016/j.clinbiomech.2004.04.012 ↗
19. Perren SM, Klaue K, Pohler O, Predieri M, Steinemann S, Gautier E. The limited contact dynamic compression plate (LC-DCP). Arch Orthop Trauma Surg. 1990;109:304–10.10.1007/BF00636166 ↗
20. Niemeyer P, Sudkamp NP. Principles and clinical application of the locking compression plate (LCP). Acta Chir Orthop Traumatol cCech. 2006;73(4):221–8.10.55095/achot2006/032 ↗
21. Gardner MP, Chong ACM, Pollock AG, Wooley PH. Mechanical evaluation of large-size fourth generation composite femur and tibia models. Ann Biomed Eng. 2010;3(38):613–20.10.1007/s10439-009-9887-7 ↗
22. Faruok O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H. Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaver infection study. Injury. 1997;28:SA7–12.10.1016/S0020-1383(97)90110-8 ↗
23. Sommer C, Babst R, Muller M, Hanson B. Locking compression plate loosening and plate breakage: a report of four cases. J Orthop Trauma. 2004;18(8):571–7.10.1097/00005131-200409000-00016 ↗
24. Stoffel K, Dieter U, Stachowiak G, Gachter A, Kuster M. Biomechanical testing of the LCP: how can stability in locked internal fixators be controlled? Injury. 2003;34:11–9.10.1016/j.injury.2003.09.021 ↗
25. Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003;34:63–76.10.1016/j.injury.2003.09.026 ↗
26. Edwards T, Eelen G, English H, Crawford R. Stripping torque as a predictor of successful internal facture fixation. Surgery. 2005;75:1096–9.
27. Gardner MJ, Griffith MH, Demetrakopoulos D, Brophy RH, Grose A, Helfet DL, Lorich DG. Hybrid locked plating of osteoporotic fractures of the humerus. J Bone Joint Surg. 2006;88A(9):1962–7.10.2106/JBJS.E.00893 ↗
28. Gaines D, Ervin T, Rudd J, Goullett R, Keyser R, Currey T, Nowotarski PJ, Norris BL. Plate length, screw position, and locking screw effects on bridge plating for femur fractures. In: 23rd Annual Mtg, of the Mid-America Orthopaedic Association, Amelia Island; 2005.
29. Sikes J, Smith B, Mukhertee D, Coward K. Comparison of fixation strengths of locking head and conventional screws in fracture and reconstruction models. J Oral Maxillofacial Surg. 1998;56:468–73.10.1016/S0278-2391(98)90715-7 ↗
30. Jewell DP, Gheduzzi AS, Mitchell MS, Miles AW. Locking plates increase the strength of dynamic hip screws. Injury, Int J Care Inj. 2008;39:209–12.10.1016/j.injury.2007.05.018 ↗