Electrochemical behaviour and surface characterisation of Zr exposed to an SBF solution containing glycine, in view of dental implant applications
Source abstract
Abstract
Zr and Ti alloys are extensively used in the biomedical field owing to their optimal mechanical properties and excellent corrosion resistance. Fully ceramic implants based on zirconia are appealing with respect to the traditional Ti-based metallic ones for several reasons, such as: (i) improved aesthetic impact, (ii) better biocompatibility and (iii) better osteointegration. Nevertheless, fully ceramic implants exhibit serious mechanical and clinical drawbacks, chiefly brittleness and impossibility of post-implant position adjustments. In this paper we propose the novel approach of using a metal-based system, consisting of metallic Zr, for the bulk of the implant and an electrochemically grown zirconia coating, ensuring contact of the ceramic with the biological environment and isolation from the underlying metal. This solution combines the outstanding mechanical properties of the metal in the bulk with the optimal biochemical properties exclusively where they are needed: at the surface. The present paper-focussed on the electrochemical behaviour of the proposed system at the implant-wound and implant-growing bone interface-reports a time-dependent electrochemical corrosion study of zirconia-coated zirconium, performed in the following ways: (i) exposure and measurements in SBF (simulating the inorganic part of human plasma, relevant to wound chemistry), (ii) exposure and measurements in SBF with added glycine (the simplest, ubiquitous amino acid found in proteins), (iii) exposure in SBF with added glycine and measurements in SBF. Electrochemical impedance spectra were measured and interpreted with the equivalent-circuit approach, yielding estimates of the time-variation of the oxide film thickness and resistance were estimated. FT-IR, Surface Raman and VIS reflectance spectroscopies were used to characterise the surface before and after the exposure to SBF solutions. Spectroelectrochemical measurements revealed an higher corrosion resistance of the oxide films formed on Zr in the presence of glycine in the SBF matrix and a smoother electrode surface.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Bozzini B, Carlino P, D’Urzo L, Pepe V, Mele C, Venturo F. An electrochemical impedance investigation of the behaviour of anodically oxidised titanium in human plasma and cognate fluids, relevant to dental applications. J Mater Sci Mater Med. 2008;19:3443–53.10.1007/s10856-008-3487-1 ↗
2. Kobayashi E, Doi H, Yoneyama T, Hamanaka H, Gibson IR, Best SM, Shelton JC, Bonfield W. Influence of aging heat treatment on mechanical properties of biomedical Ti-Zr based ternary alloys containing niobium. J Mater Sci Mater Med. 1998;9:625–30.10.1023/A:1008927407556 ↗
3. Tanaka Y, Nakai M, Akahori T, Niinomi M, Tsutsumi Y, Doi H, Hanawa T. Characterization of air-formed surface oxide film on Ti-29Nb-13Ta-4.6Zr alloy surface using XPS and AES. Corros Sci. 2008;50:2111–6.10.1016/j.corsci.2008.06.002 ↗
4. Khan MA, Williams RL, Williams DF. The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions. Biomaterials. 1999;20:631–7.10.1016/S0142-9612(98)00217-8 ↗
5. Yun YH, Turittu VT, Daigle KP, Kovacs P, Davidson JA, Slack SM. Initial hemocompatibility studies of titanium and zirconium alloys: prekallikrein activation, fibrinogen adsorption, and their correlation with surface electrochemical properties. J Biomed Mater. 1996;32:77–85.10.1002/(SICI)1097-4636(199609)32:1<77::AID-JBM9>3.0.CO;2-M ↗
6. Ito A, Okazaki Y, Tateishi T, Ito Y. In vitro biocompatibility, mechanical-properties, and corrosion-resistance of Ti-Zr-Nb-Ta-Pd and Ti-Sn-Nb-Ta-Pd alloys. J Biomed Mater Res. 1995;29:893–9.10.1002/jbm.820290715 ↗
7. Kertzman Z, Marchai J, Suarez M, Staia MH, Filip P, Kohli P, Aouadi SM. Mechanical, tribological, and biocompatibility properties of ZrN-Ag nanocomposite films. J Biomed Mater Res A. 2008;84A:1061–7.10.1002/jbm.a.31533 ↗
8. Okazaki Y, Gotoh E. Implant applications of highly corrosion-resistant Ti-15Zr-4Nb-4Ta alloy. Mater Trans. 2002;43:2943–8.10.2320/matertrans.43.2943 ↗
9. Okazaki Y, Gotoh E. Comparison of metal release from various metallic biomaterials in vitro. Biomaterials. 2005;26:11–21.10.1016/j.biomaterials.2004.02.005 ↗
10. Okazaki Y. Dental casting properties of Ti-15Zr-4Nb-4Ta alloy. Mater Trans. 2002;43:3134–41.10.2320/matertrans.43.3134 ↗
11. Hendry JA, Pillar RM. The fretting corrosion resistance of PVD surface-modified orthopedic implant alloys. J Biomed Mater Res B. 2001;58:156–66.10.1002/1097-4636(2001)58:2<156::AID-JBM1002>3.0.CO;2-H ↗
12. Eisenbarth E, Velten D, Müller M, Thull R, Breme. Biocompatibility of beta-stabilizing elements of titanium alloys. Biomaterials. 2004;25:5705–13.10.1016/j.biomaterials.2004.01.021 ↗
13. Ardlin BI, Dahl J, Tibbals JE. Static immersion and irritation tests of dental metal-ceramic alloys. Eur J Oral Sci. 2005;113:83–9.10.1111/j.1600-0722.2005.00187.x ↗
14. Tsutsumi Y, Nishimura D, Doi H, Nomura N, Hanawa T. Initial hemocompatibility studies of titanium and zirconium alloys: prekallikrein activation, fibrinogen adsorption, and their correlation with surface electrochemical properties. Mater Sci Eng. 2009;C29:1702–8.10.1016/j.msec.2009.01.016 ↗
15. Godley R, Starosvetsky D, Gotman I. Bonelike apatite formation on niobium metal treated in aqueous NaOH. J Mater Sci Mater Med. 2004;15:1073–7.10.1023/B:JMSM.0000046388.07961.81 ↗
16. Aparicio C, Gil FC, Fonseca C, Barbosa M, Planell JA. Corrosion behaviour of commercially pure titanium shot blasted with different materials and sizes of shot particles for dental implant applications. Biomaterials. 2003;23:263–73.10.1016/S0142-9612(02)00314-9 ↗
17. Pan J, Thierry D, Leygaf C. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application. Electrochim Acta. 1996;41:1143–53.10.1016/0013-4686(95)00465-3 ↗
18. Hitzig K, Juttner WJ, Lorenz W, Paatsch J. AC-Impedance measurements on corroded porous aluminum-oxide films. J Electrochem Soc. 1986;133:887.10.1149/1.2108756 ↗
19. Mansfeld F, Kendig MW. Evaluation of anodized aluminum surfaces with electrochemical impedance spectroscopy. J Electrochem Soc. 1988;135:828–33.10.1149/1.2095786 ↗
20. van Westing EPM, Ferrari GM, de Wit JHW. The determination of coating performance with impedance measurements. 1. Coating polymer properties. Corr Sci. 1993;34:1511–30.10.1016/0010-938X(93)90245-C ↗
21. Lavos-Valereto IC, Costa I, Wolynec S. The electrochemical behavior of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating in Hank’s solution. J Biomed Mater Res B Appl Biomater. 2002;63:664–70.10.1002/jbm.10351 ↗
22. Bozzini B, Sgura I. A class of mathematical models for alternated-current electrochemical measurements accounting for non-linear effects. Nonlinear Anal Real World Appl. 2008;9:412–37.10.1016/j.nonrwa.2006.11.009 ↗
23. González JEG, Mirza-Rosca JC. Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications. J Electroanal Chem. 1999;471:109–15.10.1016/S0022-0728(99)00260-0 ↗
24. Wong MS, Antonelli DM, Ying JY. Synthesis and characterization of phosphated mesoporous zirconium oxide. Nanostruct Mater. 1997;9:165–8.10.1016/S0965-9773(97)00044-5 ↗
25. Colthup NB, Daly LH. Introduction to infrared and Raman spectroscopy. San Diego: Academic Press, Inc.; 1990. p. 363–6.
26. Iwasita T, Nart FC. In-situ infrared Fourier transform spectroscopy: a tool to characterize the metal-electrolyte interface at a molecular level. In: Gerischer H, Tobias CW, editors. Advances in electrochemical science and engineering, vol 4. Weinheim: VCH; 1995. p. 169–71.10.1002/9783527616787.ch3 ↗
27. Nakamoto K. Infrared and Raman spectra of inorganic and coordination compounds. New York: Wiley; 1997. p. 266.
28. Müller L, Müller FA. Preparation of SBF with different HCO3 − content and its influence on the composition of biomimetic apatites. Acta Biomater. 2006;2:181–9.10.1016/j.actbio.2005.11.001 ↗
29. Ghosh A, Suri AK, Pandey M, Thomas S, Rama Mohan TR, Rao BT. Nanocrystalline zirconia-yttria system—a Raman study. Mater Lett. 2006;60:1170–3.10.1016/j.matlet.2005.10.102 ↗
30. Fischer G, Cao X, Cox N, Francis M. The FT-IR spectra of glycine and glycylglycine zwitterions isolated in alkali halide matrices. Chem Phys. 2005;313:39–49.10.1016/j.chemphys.2004.12.011 ↗
31. De Gelder J, De Gussem K, Vandenbeele P, Moens L. Reference database of Raman spectra of biological molecules. J Raman Spectrosc. 2007;38:1133–47.10.1002/jrs.1734 ↗
32. Ahmad R, Melsheimer J, Jentoft FC, Schlögl R. Isomerization of n-butane and of n-pentane in the presence of sulfated zirconia: formation of surface deposits investigated by in situ UV-vis diffuse reflectance spectroscopy. J Catal. 2003;218:365–74.10.1016/S0021-9517(03)00144-1 ↗