journal article·2009-12

Characterization of surface modified polyester fabric

Roy Joseph, R. Shelma, A. Rajeev, C. V. Muraleedharan

Publisher page

Abstract

Woven polyethylene terephthalate (PET) fabric has been used in the construction of vascular grafts and sewing ring of prosthetic heart valves. In an effort to improve haemocompatibility and tissue response to PET fabric, a fluoropolymer, polyvinylidine fluoride (PVDF), was coated on PET fabric by dip coating technique. The coating was found to be uniform and no significant changes occurred on physical properties such as water permeability and burst strength. Cell culture cytotoxicity studies showed that coated PET was non-cytotoxic to L929 fibroblast cell lines. In vitro studies revealed that coating improved haemocompatibility of PET fabric material. Coating reduced platelet consumption of PET fabric by 50%. Upon surface modification leukocyte consumption of PET was reduced by 24%. About 60% reduction in partial thromboplastin time (PTT) observed when PET was coated with PVDF. Results of endothelial cell proliferation studies showed that surface coating did not have any substantial impact on cell proliferation. Overall results indicate that coating has potential to improve haemocompatibility of PET fabric without affecting its mechanical performance.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Polymer Surface Interaction Studies · Infectious Aortic and Vascular Conditions

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. J. Eldrup-Jorgensen, W.C. Mackey, R.J. Connolly, J.L. Mccullough, K. Ramberg, V. Gavris, T.F. O’donnell, A.D. Callow, Am. J. Surg. 150, 185 (1985)10.1016/0002-9610(85)90116-3 ↗
2. R. Kowalewski, L. Zimnoch, M.Z. Wojtukiewicz, S. Glowinski, J. Glowinski, Blood Coagul. Fibrinolysis 14, 433 (2003)10.1097/00001721-200307000-00002 ↗
3. H.P. Greisler, T.H. Schwarcz, J. Ellinger, D.U. Kim, J. Vasc. Surg. 3, 747 (1986)10.1016/0741-5214(86)90039-X ↗
4. Y. Noishiki, Y. Tomizawa, Y. Yamane, A. Matsumoto, Artif. Organs 19, 7 (1995)10.1111/j.1525-1594.1995.tb02238.x ↗
5. T. Yoneyama, M. Ito, K. Sugihara, K. Ishihara, N. Nakabayashi, Artif. Organs 24, 23 (2000)10.1046/j.1525-1594.2000.06433.x ↗
6. T. Yoneyama, K. Sugihara, K. Ishihara, Y. Iwasaki, N. Nakabayashi, Biomaterials 23, 145 (2002)10.1016/S0142-9612(01)00268-X ↗
7. K.S. Tweden, H. Harasaki, M. Jones, J.M. Blevitt, W.S. Craig, M. Pierschbacher, M.N. Helmus, J. Heart Valve Dis. 4, S90 (1995)
8. M.K. Dewanjee, D.R. Gross, P. Zhai, S. Lanzo, H. Shim, K. Park, D.J. Schaeffer, A.R. Twardock, J. Heart Valve Dis. 8, 324 (1999)
9. L.-B. Sun, J. Utoh, S. Moriyama, H. Tagami, K. Okamoto, N. Kitamura, ASAIO J. 47, 325 (2001)10.1097/00002480-200107000-00005 ↗
10. U. Walschus, H. Goldmann, T. Ueberrueck, A. Hoene, L. Wilhelm, M. Schlosser, J. Mater. Sci.: Mater. Med. 19, 1595 (2008)10.1007/s10856-007-3316-y ↗
11. S.W. Shalaby, U.S. Patent 7,348,364, 2008
12. J.A. Chinn, J.A. Sauter, R.E. Phillips, W.J. Kao, J.M. Anderson, S.R. Hanson, T.R. Ashton, J. Biomed. Mater. Res. 39, 130 (1998)10.1002/(SICI)1097-4636(19980101)39:1<130::AID-JBM15>3.0.CO;2-J ↗
13. L. Pedrini, M. Dondi, A. Magagnoli, F. Magnoni, E. Pisano, E.D. Giudice, M. Santoro, Ann. Vasc. Surg. 15, 679 (2001)10.1007/s100160010129 ↗
14. A. Margovsky, H. Parsson, A. Chao, R.S.A. Lord, Eur. J. Vasc. Endovasc. Surg. 23, 39 (2002)10.1053/ejvs.2001.1538 ↗
15. International Standard ISO 7198 (1998 E), Cardiovascular implants—tubular vascular prostheses
16. International Standard ISO 10993-5 (1999), Biological evaluation of medical devices—Part 5: Tests for in vitro cytotoxicity
17. International Standard ISO 10993-4 (2002 E), Biological evaluation of medical devices—Part 4: Selection of tests for interactions with blood