Enhanced mechanical properties and biosafety evaluation of surface-modified fiberglass-reinforced resin-based composite piles
Source abstract
Abstract
The purpose of this study is to analyze various surface grafting modifications of fiberglass-reinforced resin based composite piles. In addition, the effects of surface modifications of fiberglass-reinforced resin piles in terms of biosafety and mechanical strength were studied. According to different surface treatment methods, the fiberglass was divided into five groups (A-E): a blank control group, a KH570 processing group, a KH570 processing+Bis-GMA grafting 1 h group, a KH570 processing+Bis-GMA grafting 3 h group and a KH570 processing+Bis-GMA grafting 7 h group. All surface-treated materials were characterized using scanning electron microscope, thermogravimetric analyses and Fourier transform infrared spectrum and mechanical testing using a universal mechanical tester. The biosafety was evaluated by cell viability experiments and repeated oral toxicity tests and Ames tests. The Bis-GMA grafting modification further enhanced the mechanical properties of resin piles. By increasing the grafting time, the grafting effect and mechanical properties were further enhanced. The surfaces grafted for 7 h (Group E) remarkably improved the mechanical properties (flexural strength ~696.24 MPa; flexural load ~185.67N). The graft modifications improved the mechanical properties of fiber pile resin-based materials. The prolonged grafting time further improved the mechanical properties corresponding to enhanced grafting and the formation of a stable interface between fibers and the resin matrix. The surface-modified dental resin-based fiber did not show any signs of toxicity, cytotoxicity or mutagenicity, suggesting the potential biological safety of these materials in the clinical practice.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Innovations in Concrete and Construction Materials · biodegradable polymer synthesis and properties · Microplastics and Plastic Pollution
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. Reeh ES, Messer HH, Douglas WH. Reduction in tooth stiffness as a result of endodontic and restorative procedures. J Endod. 1989;15:512–7.10.1016/S0099-2399(89)80191-8 ↗
2. Martinez-Insua A, Da Silva L, Rilo B, Santana U. Comparison of the fracture resistances of pulpless teeth restored with a cast post and core or carbon-fiber post with a composite core. J Prosthet Dent. 1998;80:527–32.10.1016/S0022-3913(98)70027-7 ↗
3. Creugers NH, Mentink AG, Käyser AF. An analysis of durability data on post and core restorations. J Dent. 1993;21:281–4.10.1016/0300-5712(93)90108-3 ↗
4. Goracci C, Ferrari M. Current perspectives on post systems: a literature review. Aust Dent J. 2011;56:77–83.10.1111/j.1834-7819.2010.01298.x ↗
5. Lamichhane A, Xu C, Zhang FQ. Dental fiber-post resin base material: a review. J Adv Prosthodont. 2014;6:60–5.10.4047/jap.2014.6.1.60 ↗
6. Spalten RG. Composite resins to restore mutilated teeth. J Prosthet Dent. 1971;25:323–6.10.1016/0022-3913(71)90194-6 ↗
7. Baraban DJ. Immediate restoration of pulpless teeth. J Prosthet Dent. 1972;28:607–12.10.1016/0022-3913(72)90109-6 ↗
8. Duret B, Reynaud M, Duret F. New concept of coronoradicular reconstruction: the Composipost (1). Chir Dent Fr. 1990;60:131–41.
9. Figueiredo FE, Martins-Filho PR, Faria-E-Silva AL. Do metal post-retained restorations result in more root fractures than fiber post-retained restorations? A systematic review and meta-analysis. J Endod. 2015;41:309–16.10.1016/j.joen.2014.10.006 ↗
10. Garoushi S, Tanner J, Vallittu P, Lassila L. Preliminary clinical evaluation of short fiber-reinforced composite resin in posterior teeth: 12-months report. Open Dent J. 2012;6:41–5.10.2174/1874210601206010041 ↗
11. Lamichhane A, Xu C, Zhang FQ. Dental fiber-post resin base material: a review. J Adv Prosthodont. 2014;6:60–5.10.4047/jap.2014.6.1.60 ↗
12. Visco AM, Calabrese L, Campo N, Torrisi L, Oteri G, Lo Giudice G, et al. Mechanical behavior of quartz fiber reinforced epoxy resins for teeth restoration. Biomed Mater Eng. 2006;16:349–58.
13. Garcia PP, da Costa RG, Garcia AV, Gonzaga CC, da Cunha LF, Rezende CE, et al. Effect of surface treatments on the bond strength of CAD/CAM fiberglass posts. J Clin Exp Dent. 2018;10:e591–7.
14. Dakshinamoorthy A, Singaravel Chidambaranathan A, Balasubramanium M. Evaluation of shear bond strength between maxillofacial silicone and fiber-reinforced composite resin after various surface treatments. J Prosthet Dent. 2018;119:1029.e1–e5.10.1016/j.prosdent.2018.04.003 ↗
15. Nokar S, Bahrami M, Mostafavi AS. Comparative evaluation of the effect of different post and core materials on stress distribution in radicular dentin by three-dimensional finite element analysis. J Dent. 2018;15:69–78.
16. Pegoretti A, Fambri L, Zappini G, Bianchetti M. Finite element analysis of a glass fiber reinforced composite endodontic post. Biomaterials. 2002;23:2667–82.10.1016/S0142-9612(01)00407-0 ↗
17. Farina AP, Weber AL, Severo Bde P, Souza MA, Cecchin D. Effect of length post and remaining root tissue on fracture resistance of fibre posts relined withresin composite. J Oral Rehabil. 2015;42:202–8.10.1111/joor.12243 ↗
18. Romeed SA, Dunne SM, Madarati AA. The impact of fractured endodontic file removal on vertical root fracture resistance: three-dimensional finite element analysis. Eur J Prosthodont Restor Dent. 2012;20:86–91.
19. Assif D, Bitenski A, Pilo R, Oren E. Effect of post design on resistance to fracture of endodontically treated teeth with complete crowns. J Prosthet Dent. 1993;69:36–40.10.1016/0022-3913(93)90237-I ↗
20. Liu M, Chen J, Hu X, Du Y, Xia Y, Gu N, et al. Enhanced properties of fiberglass-reinforced photocurable resin pile by introducing different fiberglass surface treatments and their biological evolution. Rsc Adv. 2015;5:69690–7.10.1039/C5RA08964F ↗
21. Luo N, Zhong H, Yang M, Yuan X, Fan Y. Modifying glass fiber surface with grafting acrylamide by UV-grafting copolymerization for preparation of glass fiber reinforced PVDF composite membrane. J Environ Sci. 2016;39:208–17.10.1016/j.jes.2015.11.010 ↗
22. Liu F, Wang R, Cheng Y, Jiang X, Zhang Q, Zhu M. Polymer grafted hydroxyapatite whisker as a filler for dental composite resin with enhanced physical and mechanical properties. Mater Sci Eng C Mater Biol Appl. 2013;33:4994–5000.10.1016/j.msec.2013.08.029 ↗
23. Wang R, Bao S, Liu F, Jiang X, Zhang Q, Sun B, et al. Wear behavior of light-cured resin composites with bimodal silica nanostructures as fillers. Mater Sci Eng C Mater Biol Appl. 2013;33:4759–66.10.1016/j.msec.2013.07.039 ↗
24. Wang R, Zhang M, Liu F, Bao S, Wu T, Jiang X, et al. Investigation on the physical-mechanical properties of dental resin composites reinforced with novel bimodal silica nanostructures. Mater Sci Eng C Mater Biol Appl. 2015;50:266–73.10.1016/j.msec.2015.01.090 ↗
25. Wolff D, Geiger S, Ding P, Staehle HJ, Frese C. Analysis of the interdiffusion of resin monomers into pre-polymerized fiber-reinforced composites. Dent Mater. 2012;28:541–7.10.1016/j.dental.2011.12.001 ↗
26. Gonçalves F, Baaro LC, Miyazaki CL, Kawano Y, Braga RR. Influence of polymeric matrix on the physical and chemical properties of experimental composites. Braz Oral Res. 2015;29:1–7.10.1590/1807-3107BOR-2015.vol29.0128 ↗
27. Bahramian N, Atai M, Naimi-Jamal MR. Ultra-high-molecular-weight polyethylene fiber reinforced dental composites: effect of fiber surface treatment on mechanical properties of the composites. Dent Mater. 2015;31:1022–9.10.1016/j.dental.2015.05.011 ↗
28. Bocalon ACE, Mita D, Natale LC, Pfeifer CS, Braga RR. Polymerization stress of experimental composites containing random short glass fibers. Dent Mater. 2016;32:1079–84.10.1016/j.dental.2016.06.006 ↗
29. Karbhari VM, Strassler H. Effect of fiber architecture on flexural characteristics and fracture of fiber-reinforced dental composites. Dent Mater. 2007;23:960–8.10.1016/j.dental.2006.08.003 ↗
30. Khan AS, Hussain AN, Sidra L, Sarfraz Z, Khalid H, Khan M, et al. abrication and in vivo evaluation of hydroxyapatite/carbon nanotube electrospun fibers for biomedical/dental application. Mater Sci Enq C Mater Biol Appl. 2017;80:387–96.10.1016/j.msec.2017.05.109 ↗
31. Ribeiro DA, Yujra VQ, DE Moura CFG, Handan BA, DE Barros Viana M, Yamauchi LY, et al. Genotoxicity induced by dental materials: a comprehensive review. Anticancer Res. 2017;37:4017–24.