Mechanical and fracture behavior of a fiber-reinforced bioabsorbable material for orthopaedic applications

J. L. Charvet, J. A. Cordes, H. Alexander

Publisher page

Abstract

Tensile and fracture tests were conducted on thin panels of a fiber-reinforced bioabsorbable material. The composites were made of polycarbonate matrix and calcium phosphate fibers. Both matrix and fibers were bioabsorbable orthopaedic biomaterials. The fibers were short and randomly distributed. The properties were compared for composites with and without a coating of methane on the fibers. Composites with the methane coating had a higher elastic modulus, a higher proportional limit, but a lower load at failure on pre-cracked panels. Electron microscopy showed that the coating resulted in a better bond between the matrix and the fiber.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Bone fractures and treatments · biodegradable polymer synthesis and properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (21)

Show source-provided references
1. E. Y. S. Chao, H. T. Aru and N. Inoue, “Engineering Principles for Bone Fracture Fixation and Repair,” in Biomedical Applications of Synthetic Biodegradable Polymers, Edited by J. O. Hollinger (CRC Press, Boca Raton, 1995) p. 145.
2. M. H. Mayer and J. O. Hollinger, “Biodegradable Bone Fixation Devices,” in Biomedical Applications of Synthetic Biodegradable Polymers, edited by J. O. Hollinger (CRC Press, Boca Raton, 1995) p. 173.
3. C. C. P. M. Verheyen, J. R. De wijn, C. A. Van bitterswijk and K. de Groot, “Evaluation of hydroxyapatite-PLLA composite: Mechanical behavior,” J. Biomed. Mat. Res. 26 (1992) 1277.10.1002/jbm.820261003 ↗
4. N. R. Boree, J. Dove, J. J. Cooper, J. Knowled and G. W. Hastings, “Development of a degradable composite for orthopaedic use: mechanical evaluation of an hydroxyapatite-polyhydroxybutyrate composite material,” Biomater. 14 (1993) 793.10.1016/0142-9612(93)90046-5 ↗
5. J. M. Anderson, “Perspectives on the in vivo response of biodegradable polymers,” in Biomedical Applications of Synthetic Biodegradable Polymers edited by J. O. Hollinger (CRC Press, Boca Raton, 1995) p. 223.
6. A. Gopferich, “Mechanisms of polymer degradation and erosion,” Biomater. 17 (1996) 103.10.1016/0142-9612(96)85755-3 ↗
7. K. A. Athanasiou, G. C. Nierderauer and C. M. Agrawal, “Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/polyglycolic acid copolymers,” Biomater. 17 (1996) 93.10.1016/0142-9612(96)85754-1 ↗
8. S. I. Ertel, J. Kohn, M. C. Zimmerman and J. R. Parsons, “Evaluation of poly(DTH carbonate), a tyrosine-derived degradable polymer, for orthopaedic applications,” J. Biomed. Mater. Res. 29 (1995) 1337.10.1002/jbm.820291105 ↗
9. S. I. Ertel and J. Kohn, “Evaluation of a series of tyrosine-derived polycarbonates as degradable biomaterials,” J. Biomed. Mat. Res. 28 (1994) 1.10.1002/jbm.820280102 ↗
10. J. Choueka, J. L. Charvet, K. J. Koval, H. Alexander, K. S. James, K. A. Hooper and J. Kohn, “Canine bone response to tyrosine-derived polycarbonates and poly(L-lactic acid),” J. Biomed. Mater. Res. 31 (1996) 35.10.1002/(SICI)1097-4636(199605)31:1<35::AID-JBM5>3.0.CO;2-R ↗
11. R. A. Latour, “Fiber Reinforced Composite Biomaterials for Orthopedic Implant Applications,” in Encyclopedic Handbook of Biomaterials and Bioengineering, Part B Vol. 1. D. L. Wise, et al. Marcel Dekker, (New York, 1995), p. 359.
12. S. W. Shalaby, “Bioabsorbable polymers update: degradation mechanisms, safety and applications,” J. Appl. Biomat. 6 (1995) 219.10.1002/jab.770060313 ↗
13. R. F. Storey and J. S. Wiggins, “Design and fabrication of polyester-fibre and matrix composites for totally bioabsorbable biomaterials,” Med. Plast. Biomat. 3 (1996) 41.
14. S. T. Lin, S. L. Krebs, S. Kadiyala, K. W. Leong, W. C. Lacourse, B. Kumar, “Development of bioabsorbable glass fibres,” Biomater. 15 (1994) 1057.10.1016/0142-9612(94)90091-4 ↗
15. J. Choueka, J. L. Charvet, H. Alexander, Y. H. Oh, G. Joseph, N. C. Blumenthal, W. C. Lacourse, “Effect of annealing temperature on the degradation of reinforcing fibres for absorbable implants,” J. Biomed. Mat. Res. 29 (1995) 1309.10.1002/jbm.820291102 ↗
16. B. J. Perez, H. Alexander, C. W. Mayott, L. Anderson, J. L. Charvet, J. Kohn, W. C. Lacourse, I. Loh, “Effect of fibre-matrix coupling on the mechanical properties of a totally bioabsorbable composite,” Trans. of the 5th World Biomater. Congress, 1996.
17. S. Pulapura and J. Kohn, “Trends in the development of bioresorbable polymers for medical applications,” J. Appl. Biomat. 6 (1992) 216.10.1177/088532829200600303 ↗
18. M. S. Sheu, D. M. Hudson, I. H. Loh, “Biomaterials Surface Modification Using Plasma Gas Discharge Process,” in: Encyclopedic Handbook of Biomaterials and Bioengineering, Part A Vol. 1, edited by Wise D. L., et al. Marcel Dekker, (New York, 1995) pp. 865-894.
19. ASTM D3039-76, 1995.
20. ASTM E399-81, 1995.
21. J. A. Cordes and R. Yazici, “Predicting Crack Growth in Continuous-Fiber Composite Materials,” in Fracture Mechanics: 26th Vol, ASTM STP 1256. Edited by W. G. Reuter, J. H. Underwood, J. C. Newman ( ASTM, Philadelphia, 1995).