journal article·2013-06Open access

Creep and fatigue behavior of a novel 2-component paste-like formulation of acrylic bone cements

Ulrike Köster, Raimund Jaeger, Mareike Bardts, Christian Wahnes, Hubert Büchner, Klaus-Dieter Kühn, Sebastian Vogt

Abstract

The fatigue and creep performance of two novel acrylic bone cement formulations (one bone cement without antibiotics, one with antibiotics) was compared to the performance of clinically used bone cements (Osteopal V, Palacos R, Simplex P, SmartSet GHV, Palacos R+G and CMW1 with Gentamicin). The preparation of the novel bone cement formulations involves the mixing of two paste-like substances in a static mixer integrated into the cartridge which is used to apply the bone cement. The fatigue performance of the two novel bone cement formulations is comparable to the performance of the reference bone cements. The creep compliance of the bone cements is significantly influenced by the effects of physical ageing. The model parameters of Struik's creep law are used to compare the creep behavior of different bone cements. The novel 2-component paste-like bone cement formulations are in the group of bone cements which exhibit a higher creep resistance.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (47)

Show source-provided references
1. Morlock M, Schneider E, Bluhm A, Vollmer M, Bergmann G, Müller V, et al. Duration and frequency of every day activities in total hip patients. J Biomech. 2001;34(7):873–81.10.1016/S0021-9290(01)00035-5 ↗
2. Quinn J, Joyner C, Triffitt JT, Athanasou NA. Polymethylmethacrylate-induced inflammatory macrophages resorb bone. J Bone Joint Surg Br. 1992;74(5):652–8.10.2106/00004623-199274050-00004 ↗
3. Sabokbar A, Fujikawa Y, Brett J, Murray DW, Athanasou NA. Increased osteoclastic differentiation by PMMA particle-associated macrophages. Inhibitory effect by interleukin 4 and leukemia inhibitory factor. Acta Orthop Scand. 1996;67(6):593–8.10.3109/17453679608997763 ↗
4. Kadoya Y, Revell PA, Kobayashi A, al-Saffar N, Scott G, Freeman MA. Wear particulate species and bone loss in failed total joint arthroplasties. Clin Orthop Relat Res. 1997;340:118–29.10.1097/00003086-199707000-00016 ↗
5. Topoleski LD, Ducheyne P, Cuckler JM. A fractographic analysis of in vivo poly(methyl methacrylate) bone cement failure mechanisms. J Biomed Mater Res. 1990;24(2):135–54.10.1002/jbm.820240202 ↗
6. Culleton TP, Prendergast PJ, Taylor D. Fatigue failure in the cement mantle of an artificial hip joint. Clin Mater. 1993;12(2):95–102.10.1016/0267-6605(93)90056-D ↗
7. Raab S, Ahmed AM, Provan JW. The quasistatic and fatigue performance of the implant/bone-cement interface. J Biomed Mater Res. 1981;15(2):159–82. doi: 10.1002/jbm.820150205 .10.1002/jbm.820150205 ↗
8. Soltész U. The influence of loading conditions on the life-times in fatigue testing of bone cements. J Mater Sci Mater Med. 1994;5(9–10):654–6.10.1007/BF00120350 ↗
9. Tepic S, Soltesz U. Fatigue of bone cement with simulated stem interface porosity. J Mater Sci Mater Med. 1998;9(12):707–9.10.1023/A:1008942600230 ↗
10. Dunne NJ, Orr JF, Mushipe MT, Eveleigh RJ. The relationship between porosity and fatigue characteristics of bone cements. Biomaterials. 2003;24(2):239–45.10.1016/S0142-9612(02)00296-X ↗
11. Stolk J, Verdonschot N, Murphy BP, Prendergast PJ, Huiskes R. Finite element simulation of anisotropic damage accumulation and creep in acrylic bone cement. Eng Fract Mech. 2004;71(4–6):513–28.10.1016/S0013-7944(03)00048-1 ↗
12. Kim DG, Miller MA, Mann KA. A fatigue damage model for the cement-bone interface. J Biomech. 2004;37(10):1505–12.10.1016/j.jbiomech.2004.01.011 ↗
13. Jeffers JRT, Browne M, Lennon AB, Prendergast PJ, Taylor M. Cement mantle fatigue failure in total hip replacement: experimental and computational testing. J Biomech. 2007;40(7):1525–33.10.1016/j.jbiomech.2006.07.029 ↗
14. Jeffers JRT, Browne M, Taylor M. Damage accumulation, fatigue and creep behaviour of vacuum mixed bone cement. Biomaterials. 2005;26(27):5532–41.10.1016/j.biomaterials.2005.02.009 ↗
15. Tanner KE, Wang JS, Kjellson F, Lidgren L. Comparison of two methods of fatigue testing bone cement. Acta Biomater. 2010;6(3):943–52. doi: 10.1016/j.actbio.2009.09.009 .10.1016/j.actbio.2009.09.009 ↗
16. Palt S, Saha S. Stress relaxation and creep behaviour of normal and carbon fibre reinforced acrylic bone cement. Biomaterials. 1982;3(2):93–6.10.1016/0142-9612(82)90040-0 ↗
17. Verdonschot N, Huiskes R. Creep behavior of hand-mixed Simplex P bone cement under cyclic tensile loading. J Appl Biomater. 1994;5(3):235–43. doi: 10.1002/jab.770050309 .10.1002/jab.770050309 ↗
18. Migliaresi C, Fambri L, Kolarik J. Polymerization kinetics, glass transition temperature and creep of acrylic bone cements. Biomaterials. 1994;15(11):875–81.10.1016/0142-9612(94)90110-4 ↗
19. Verdonschot N, Huiskes R. Creep properties of three low temperature-curing bone cements: a preclinical assessment. J Biomed Mater Res. 2000;53(5):498–504.10.1002/1097-4636(200009)53:5<498::AID-JBM8>3.0.CO;2-H ↗
20. Soltész U, Schäfer R, Kühn K-D. Ermüdungsverhalten von Knochenzementen nach Alterung. Biomaterialien. 2004;5(1):48–51.10.1515/BIOMAT.2004.5.1.48 ↗
21. Arnold JC, Venditti NP. Effects of environment on the creep properties of a poly(ethylmethacrylate) based bone cement. J Mater Sci Mater Med. 2001;12(8):707–17.10.1023/A:1011272626846 ↗
22. Arnold JC, Venditti NP. Prediction of the long-term creep behaviour of hydroxyapatite-filled polyethylmethacrylate bone cements. J Mater Sci Mater Med. 2007;18(9):1849–58. doi: 10.1007/s10856-007-3056-z .10.1007/s10856-007-3056-z ↗
23. Kuzmychov O, Koplin C, Jaeger R, Büchner H, Gopp U. Physical aging and the creep behavior of acrylic bone cements. J Biomed Mater Res B Appl Biomater. 2009;91(2):910–7. doi: 10.1002/jbm.b.31474 .10.1002/jbm.b.31474 ↗
24. Struik LCE. Physical Aging in Amorphous Polymers and Other Materials. Amsterdam: Elsevier; 1978.
25. Malchau H, Herberts P, Eisler T, Garellick G, Soderman P. The Swedish total hip replacement register. J Bone Joint Surg Am. 2002;84(A Suppl 2):2–20.10.2106/00004623-200200002-00002 ↗
26. Thanner J, Freij-Larsson C, Karrholm J, Malchau H, Wesslen B. Evaluation of Boneloc. Chemical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties. Acta Orthop Scand. 1995;66(3):207–14.10.3109/17453679508995525 ↗
27. Walczak JP, D’Arcy JC, Ross KR, James SE, Bonnici AV, Koka SR, et al. Low-friction arthroplasty with boneloc bone-cement: outcome at 2 to 4 years. J Arthroplasty. 2000;15(2):205–9.10.1016/S0883-5403(00)90264-X ↗
28. Abdel-Kader KF, Allcock S, Walker DI, Chaudhry SB. Boneloc bone-cement: experience in hip arthroplasty during a 3-year period. J Arthroplasty. 2001;16(7):811–9.10.1054/arth.2001.25561 ↗
29. Bae H, Hatten HP Jr, Linovitz R, Tahernia AD, Schaufele MK, McCollom V, et al. A prospective randomized FDA-IDE trial comparing Cortoss with PMMA for vertebroplasty: a comparative effectiveness research study with 24-month follow-up. Spine. 2012;37(7):544–50. doi: 10.1097/BRS.0b013e31822ba50b .10.1097/BRS.0b013e31822ba50b ↗
30. Gheduzzi S, Webb JJ, Miles AW. Mechanical characterisation of three percutaneous vertebroplasty biomaterials. J Mater Sci Mater Med. 2006;17(5):421–6. doi: 10.1007/s10856-006-8469-6 .10.1007/s10856-006-8469-6 ↗
31. Pomrink GJ, DiCicco MP, Clineff TD, Erbe EM. Evaluation of the reaction kinetics of CORTOSS, a thermoset cortical bone void filler. Biomaterials. 2003;24(6):1023–31.10.1016/S0142-9612(02)00443-X ↗
32. Deb S, Aiyathurai L, Roether JA, Luklinska ZB. Development of high-viscosity, two-paste bioactive bone cements. Biomaterials. 2005;26(17):3713–8. doi: 10.1016/j.biomaterials.2004.09.065 .10.1016/j.biomaterials.2004.09.065 ↗
33. Bredereck H, Föhlich B, Franz R, inventors; Degussa, Heraeus GmbH W C, Assignee. Polymerization of vinyl compounds and unsaturated polyesters using barbituric acids and alpha acyl nitriles as catalysts. United States 1967.
34. Föhlich B, Bredereck H, Franz R, inventors; Degussa, Heraeus GmbH assignee. Verfahren zum Polymerisieren oder Copolymerisieren von Vinylverbindungen und ungesättigten Polyestern Germany patent DE1495520, 1964.
35. (ISO 16402) IOfS. Implants for Surgery—acrylic resin cement—flexural faigue testing of acrylic resin cements used in orthopaedics. Geneva: ISO; 2008.
36. (ASTM D2990) ASfTaM. Standard test methods for tensile, compressive, and flexural creep and creep-rupture of plastics. West Conshohocken: ASTM; 2001.
37. Verdonschot N, Huiskes R. Acrylic cement creeps but does not allow much subsidence of femoral stems. J Bone Joint Surg Br. 1997;79(4):665–9.10.1302/0301-620X.79B4.7173 ↗
38. MartinezVega JJ, Trumel H, Gacougnolle JL. Plastic deformation and physical ageing in PMMA. Polymer. 2002;43(18):4979–87.10.1016/S0032-3861(02)00332-4 ↗
39. (ASTM E739-10) ASfTaM. Standard practice for statistical analysis of linear or linearized stress-life (S-N) and strain-life (e-N) fatigue data. West Conshohocken: ASTM; 2010.
40. Lewis G. Properties of acrylic bone cement: state of the art review. J Biomed Mater Res. 1997;38(2):155–82.10.1002/(SICI)1097-4636(199722)38:2<155::AID-JBM10>3.0.CO;2-C ↗
41. Hoey D, Taylor D. Quantitative analysis of the effect of porosity on the fatigue strength of bone cement. Acta Biomater. 2009;5(2):719–26. doi: 10.1016/j.actbio.2008.08.024 .10.1016/j.actbio.2008.08.024 ↗
42. Hoey DA, Taylor D. Statistical distribution of the fatigue strength of porous bone cement. Biomaterials. 2009;30(31):6309–17. doi: 10.1016/j.biomaterials.2009.07.053 .10.1016/j.biomaterials.2009.07.053 ↗
43. Atkins AG, Mai Y-W. Elastic and plastic fracture. Engineering Science. Chichester: Ellis Horwood; 1988.
44. Schmitt S, Krzypow DJ, Rimnac CM. The effect of moisture absorption on the fatigue crack propagation resistance of acrylic bone cement. Biomedizinische Technik Biomed Eng. 2004;49(3):61–5. doi: 10.1515/BMT.2004.012 .10.1515/BMT.2004.012 ↗
45. Topoleski LD, Ducheyne P, Cuckler JM. Microstructural pathway of fracture in poly(methyl methacrylate) bone cement. Biomaterials. 1993;14(15):1165–72.10.1016/0142-9612(93)90162-U ↗
46. Morgan RL, Farrar DF, Rose J, Forster H, Morgan I. Creep behavior of bone cement: a method for time extrapolation using time-temperature equivalence. J Mater Sci Mater Med. 2003;14(4):321–5.10.1023/A:1022927814801 ↗
47. Kühn K-D. Bone cements. Berlin: Springer; 2000.10.1007/978-3-642-59762-6 ↗