Blood interactions with plasticised poly (vinyl chloride): influence of surface modification
Source abstract
Abstract
Surface modification of plasticised poly (vinyl chloride) (PVC), with di-(2-ethylhexyl) phthalate (DEHP) as plasticiser, for the improvement of blood compatibility in potential clinical use such as cardiopulmonary bypass was achieved by heparinisation. The influence of surface modification on blood compatibility was assessed in terms of the influence on fibrinogen and factor XII adsorption in vitro, and the generation of thrombin-antithrombin III complex (TAT) and the complement component C3a, in vitro and ex vivo. Electron spectroscopy for chemical analysis (ESCA) was used to characterise the heparinised surface in order to correlate the surface properties with the blood response. Results indicate that at the plasticised PVC surface there is a higher content of heparin than that of the PVC and the DEHP content is lower than that present at the surface of standard plasticised PVC. The blood compatibility assessment confirms the importance of surface modification for the improvement of blood compatibility.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Cardiac and Coronary Surgery Techniques · Peripheral Artery Disease Management · Hemostasis and retained surgical items
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. J. M. COURTNEY, N. M. K. LAMBA, S. SUNDARAM and C. D. FORBES, Biomaterials 15 (1994) 73710.1016/0142-9612(94)90026-4 ↗
2. J. M. COURTNEY, S. SUNDARAM and C. D. FORBES, in Management of Bleeding Disorders in Surgical Practice, edited by C. D. FORBES and A. CUSHIERI (Oxford: Blackwell Scientific, 1993) p. 236
3. S. SUNDARAM, J. M. COURTNEY and D. P. TAGGART, Int. J. Artif. Organs 17 (1994) 11810.1177/039139889401700210 ↗
4. J. M. COURTNEY, N. M. K. LAMBA, J. D. S. GAYLOR, C. J. RYAN and G. D. O. LOWE, Artif. Organs 19 (1995) 85210.1111/j.1525-1594.1995.tb02440.x ↗
5. L. M. ROBERTSON, J. M. COURTNEY, L. IRVINE, C. JONES and G. D. O. LOWE, Artif Organs 14 (1990) 4110.1111/j.1525-1594.1990.tb01590.x ↗
6. S. W. KIM and H. JACOBS, Blood Purif. 14 (1996) 35710.1159/000170288 ↗
7. A. GUTOWSKY and S. W. KIM, Macromol. Symp. 118 (1997) 54510.1002/masy.19971180172 ↗
8. S. W. KIM and J. FEIJEN, in Critical Reviews in Biocompatibility, edited by D. Williams (CRC Press, Boca Raton, Florida, 1985) p. 229
9. J. M. COURTNEY, J. YU and S. SUNDARAM, in Immobilised Macromolecules Application Potentials, edited by U. SLEYTR, P. MESSNER, D. PUM, and M. SÁRA (Institute for Applied Biology, York, 1993) p. 17510.1007/978-1-4471-3479-4_12 ↗
10. L. C. HSU and D. P. BALDING, Process for Reducing the Thrombogenicity of Biomaterials. US Patent 5,417,969, 1995
11. K. D. PARK, A. Z. PIAO, H. JACOBS, T. OKANO and S. W. KIM, J. Polym. Sci. A: Polym. Chem. 29 (1991) 172510.1002/pola.1991.080291206 ↗
12. O. LARM, R. LARSSON and OLSSON P., Biomater. Med. Devices Artif. Organs 11 (1983) 16110.3109/10731198309118804 ↗
13. P. APPEGREN, U. RANSJO, L. BINDSLEV, F. ESPERSEN and O. LARM, Crit. Care Med. 24 (1996) 148210.1097/00003246-199609000-00009 ↗
14. O. LARM, R. LARSSON, P. OLSSON, in Heparin: Chemical and Biological Properties, Clinical Applications, edited by D. A. LANE and U. LINDAHL (CRC Press, Florida, 1989) p. 597
15. R. H. WEST, A. J. PAUL, S. HIBBERT, P. CAHALAN, M. VERHOEVEN, M. HENDRIKS and B. FOUACHE, J. Mater. Sci. Mater. Med. 6 (1995) 6310.1007/BF00120408 ↗
16. P. C. SPENCER, B. SCHMIDT, W. SAMTLEBEN, T. BOSCH and H. J. GURLAND, Trans. Am. Soc. Artif. Intern. Organs 31 (1985) 495
17. T. BOSCH, B. SCHMIDT, M. BLUMENSTEIN and H. J. GURLAND, Artif. Organs 17 (1993) 64010.1111/j.1525-1594.1993.tb00609.x ↗
18. G. ELGUE, M. BLOMBACK, P. OLSSON and J. RIESENFELD, Thromb. Haemost. 70 (1993) 28910.1055/s-0038-1649568 ↗
19. J. M. COURTNEY, N. M. K. LAMBA, S. SUNDARAM and C. D. FORBES, Biomaterials 15(10) (1994) 73710.1016/0142-9612(94)90026-4 ↗
20. H. Q. YIN, N. M. K. LAMBA, J. D. S. GAYLOR, J. M. COURTNEY, C. R. BLASS and G. D. O. LOWE, Int. J. Artif. Organs 17 (1994) 433
21. X. B. ZHAO, P WILL, H. Q. YIN, A. ESPOSITO and J. M. COURTNEY, Artif. Organs 21 (1997) 253
22. X. B. ZHAO and J. M. COURTNEY, Artif. Organs 23 (1999) 10410.1046/j.1525-1594.1999.06267.x ↗
23. P. R. CRADDOCK, J. FEHR, A. P. DALMASO, K. L. BRIGHAM and H. S. JACOB, J. Clin. Invest. 59 (1977) 87910.1172/JCI108710 ↗
24. R. E. EDENS, R. J. LINHARDT and J. M. WEILER, Complement Profile 1 (1993) 96
25. M. GUMA, C. LIGOURI, M. DELOSREYES, L. B. KEIL and V. A. DEBARI, ASAIO J. 23 (1994) 57
26. J. M. WEILER and R. J. LINHARGT, J. Immunol. 146 (1991) 388910.4049/jimmunol.146.11.3889 ↗
27. N. M. K. LAMBA, J. M. COURTNEY, J. D. S. GAYLOR and G. D. O. LOWE, Biomaterials 21 (2000) 8910.1016/S0142-9612(99)00145-3 ↗
28. V. VIDEM, L. NILSSON, P. VENGE and J. L. SVENNEVIG, Artif. Organs 15(2) (1992) 9010.1111/j.1525-1594.1991.tb00766.x ↗
29. H. O. VETTER, M. KIRIAZOPOULOU and H. D-SHAL, Int. J. Artif. Organs 17 (1994) 416
30. M. KIRSCHFINK, B. KOVACS and K. MOTTAGHY, Circ. Shock 40 (1993) 221
31. X. B. ZHAO and J. M. COURTNEY, J. Mater. Sci. Mater. Med. 14 (2003) 90510.1023/A:1025690828200 ↗