Cytocompatibility evaluation of different biodegradable magnesium alloys with human mesenchymal stem cells
Source abstract
Abstract
In the last few years, the use of biodegradable magnesium (Mg) alloys has evoked great interest in the orthopedic field due to great advantages over long-term implant materials associated with various side effects like allergy and sensitization and consequent implant removal surgeries. However, degradation of these Mg alloys results in ion release, which may cause severe cytotoxicity and undesirable complications after implantation. In this study, we investigated the cytological effects of various Mg alloys on cells that play an important role in bone repair. Eight different magnesium alloys containing varying amounts of Al, Zn, Nd and Y were either incubated directly or indirectly with the osteosarcoma cell line Saos-2 or with uninduced and osteogenically-induced human mesenchymal stem cells (MSCs) isolated from bone marrow specimens obtained from the femoral shaft of patients undergoing total hip replacement. Cell viability, cell attachment and the release of ions were investigated at different time points in vitro. During direct or indirect incubation different cytotoxic effects of the Mg alloys on Saos-2 cells and osteogenically-induced or uninduced MSCs were observed. Furthermore, the concentration of degradation products released from the Mg alloys differed. Overall, Mg alloys MgNd2, MgY4, MgAl9Zn1 and MgY4Nd2 exhibit good cytocompatibility. In conclusion, this study reveals the necessity of cytocompatibility evaluation of new biodegradable magnesium alloys with cells that will get in direct contact to the implant material. Furthermore, the use of standardized experimental in vitro assays is necessary in order to reliably and effectively characterize new Mg alloys before performing in vivo experiments.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Aluminum Alloys Composites Properties · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Witte F, Kaese V, Haferkamp H, Switzer E, Meyer-Lindenberg A, et al. In vivo corrosion of four magnesium alloys and the associated bone response. Biomaterials. 2005;26:3557–63.10.1016/j.biomaterials.2004.09.049 ↗
2. Erne P, Schier M, Resink TJ. The road to bioabsorbable stents: reaching clinical reality? Cardiovasc Intervent Radiol. 2006;29:11–6.10.1007/s00270-004-0341-9 ↗
3. Dziuba D, Meyer-Lindenberg A, Seitz JM, Waizy H, Angrisani N, Reifenrath J. Long-term in vivo degradation behaviour and biocompatibility of the magnesium alloy ZEK100 for use as a biodegradable bone implant. Acta Biomater. 2012;9(10):8548–60.10.1016/j.actbio.2012.08.028 ↗
4. Aldahmash A, Zaher W, Al-Nbaheen M, Kassem M. Human Stromal (Mesenchymal) Stem Cells: basic Biology and Current Clinical Use for Tissue Regeneration. Ann Saudi Med. 2012;32:68–77.10.5144/0256-4947.2012.68 ↗
5. Ciapetti G, Granchi D, Baldini N. The Combined Use of Mesenchymal Stromal Cells and Scaffolds for Bone Repair. Curr Pharm Des. 2012;18:1796–820.10.2174/138161212799859648 ↗
6. Witte F, Ulrich H, Palm C, Willbold E. Biodegradable magnesium scaffolds: part II: peri-implant bone remodeling. J Biomed Mater Res A. 2007;81:757–65.10.1002/jbm.a.31293 ↗
7. Gu XN, Li N, Zheng YF, Ruan L. In vitro degradation performance and biological response of a Mg–Zn–Zr alloy. Mater Sci Eng, B. 2011;176:1778–84.10.1016/j.mseb.2011.05.032 ↗
8. Fischer J, Pröfrock D, Hort N, Willumeit R, Feyerabend F. Improved cytotoxicity testing of magnesium materials. Mater Sci Eng, B. 2011;176:830–4.10.1016/j.mseb.2011.04.008 ↗
9. Sarugaser R, Lickorish D, Baksh D, Hosseini MM, Davies JE. Human umbilical cord perivascular (HUCPV) cells: a source of mesenchymal progenitors. Stem Cells. 2005;23:220–9.10.1634/stemcells.2004-0166 ↗
10. Feyerabend F, Fischer J, Holtz J, Witte F, Willumeit R, et al. Evaluation of short-term effects of rare earth and other elements used in magnesium alloys on primary cells and cell lines. Acta Biomater. 2010;6:1834–42.10.1016/j.actbio.2009.09.024 ↗
11. Liu H. The effects of surface and biomolecules on magnesium degradation and mesenchymal stem cell adhesion. J Biomed Mater Res A. 2011;99:249–60.10.1002/jbm.a.33188 ↗
12. Geis-Gerstorfer J, Schille C, Schweizer E, Rupp F, Scheideler L, et al. Blood triggered corrosion of magnesium alloys. Mater Sci Eng, B. 2011;176:1761–6.10.1016/j.mseb.2011.06.006 ↗
13. Schille C, Braun M, Wendel HP, Scheideler L, Hort N, et al. Corrosion of experimental magnesium alloys in blood and PBS: a gravimetric and microscopic evaluation. Mater Sci Eng, B. 2011;176:1797–801.10.1016/j.mseb.2011.04.007 ↗
14. Niederlaender J, Rudi P, Schweizer E, Post P, Schille C, et al. Cytocompatibility of magnesium alloys with adult human endothelial cells. Emerg Mater Res. 2013;2:274–82.10.1680/emr.13.00014 ↗
15. Kern S, Eichler H, Stoeve J, Kluter H, Bieback K. Comparative analysis of mesenchymal stem cells from bone marrow, umbilical cord blood, or adipose tissue. Stem Cells. 2006;24:1294–301.10.1634/stemcells.2005-0342 ↗
16. Dominici M, Le Blanc K, Mueller I, Slaper-Cortenbach I, Marini F, et al. Minimal criteria for defining multipotent mesenchymal stromal cells. The International Society for Cellular Therapy position statement. Cytotherapy. 2006;8:315–7.10.1080/14653240600855905 ↗
17. Ardjomandi N, Klein C, Kohler K, Maurer A, Kalbacher H, et al. Indirect coating of RGD peptides using a poly-l-lysine spacer enhances jaw periosteal cell adhesion, proliferation, and differentiation into osteogenic tissue. J Biomed Mater Res A. 2012;100A:2034–44.10.1002/jbm.a.34062 ↗
18. Mosmann T. Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays. J Immunol Methods. 1983;65:55–63.10.1016/0022-1759(83)90303-4 ↗
19. Nolte A, Walker T, Schneider M, Kray O, Avci-Adali M, et al. Small-interfering RNA-eluting surfaces as a novel concept for intravascular local gene silencing. Mol Med. 2011;17:1213–22.10.2119/molmed.2011.00143 ↗
20. Fischer J, Prosenc MH, Wolff M, Hort N, Willumeit R, et al. Interference of magnesium corrosion with tetrazolium-based cytotoxicity assays. Acta Biomater. 2010;6:1813–23.10.1016/j.actbio.2009.10.020 ↗
21. Goswami M, Yadav K, Dubey A, Sharma BS, Konwar R, et al. In vitro cytotoxicity assessment of two heavy metal salts in a fish cell line (RF). Drug Chem Toxicol. 2014;37:48–54.10.3109/01480545.2013.806531 ↗
22. Schaffer JE, Nauman EA, Stanciu LA. Cold drawn bioabsorbable ferrous and ferrous composite wires: an evaluation of in vitro vascular cytocompatibility. Acta Biomater. 2013;9:8574–84.10.1016/j.actbio.2012.07.043 ↗
23. Cipriano AF, Zhao T, Johnson I, Guan RG, Garcia S, Liu H. In vitro degradation of four magnesium-zinc-strontium alloys and their cytocompatibility with human embryonic stem cells. J Mater Sci Mater Med. 2013;24(4):989–1003.10.1007/s10856-013-4853-1 ↗
24. Johnson I, Perchy D, Liu H. In vitro evaluation of the surface effects on magnesium-yttrium alloy degradation and mesenchymal stem cell adhesion. J Biomed Mater Res A. 2012;100A:477–85.10.1002/jbm.a.33290 ↗
25. Doepke A, Kuhlmann J, Guo X, Voorhees R, Heineman W. A system for characterizing Mg corrosion in aqueous solutions using electrochemical sensors and impedance spectroscopy. Acta Biomater. 2013;9(11):9211–9.10.1016/j.actbio.2013.07.011 ↗
26. Witte F. The history of biodegradable magnesium implants: a review. Acta Biomater. 2010;6:1680–92.10.1016/j.actbio.2010.02.028 ↗