journal article·2015-01

RETRACTED ARTICLE: Effect of coupling asynchronous acoustoelectric effects on the corrosion behavior, microhardness and biocompatibility of biomedical titanium alloy strips

Xiaoxin Ye, Guoyi Tang

This record is marked as retracted by the source. Review the publisher’s notice before using its findings.
Publisher page

Abstract

The coupling asynchronous acoustoelectric effects (CAAE) of the high-energy electropulsing treatment (EPT) technique and ultrasonic surface strengthening modification (USSM) are innovatively combined in improving the surface microhardness, corrosion behavior and biocompatibility of the pre-deformed titanium alloy strips. Experimental results show that EPT and USSM processes facilitate the surface grain refining and USSM brings in the micro-dimples on the materials surface, which is attributed to the atoms diffusion acceleration under EPT and severe surface plastic deformation under USSM. These microstructure changes can not only enhance the corrosion resistance in the acidic simulated body fluids and fluoridated acidic artificial saliva but also improve the biocompatibility of the titanium alloy strip materials. Moreover, the surface microhardness of the titanium alloy strips is enhanced to improve the wear resistance. Therefore, CAAE processing is a high-efficiency and energy-saving method for obtaining biomedical titanium alloys with superior anti-corrosion performance, microhardness and biocompatibility, which can be widely applied in dental implants and artificial joint.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electromagnetic Effects on Materials · Surface Treatment and Residual Stress · Surface Treatment and Coatings

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Hayakawa S, Masuda Y, Okamoto K, Shirosaki Y, Kato K, Osaka A. Liquid phase deposited titania coating to enable in vitro apatite formation on Ti6Al4V alloy. J Mater Sci. 2014;25:375–81.
2. Rosalbino F, Delsante S, Borzone G, Scavino G. Influence of noble metals alloying additions on the corrosion behaviour of titanium in a fluoride-containing environment. J Mater Sci. 2012;23:1129–37.
3. Zareidoost A, Yousefpour M, Ghaseme B, Amanzadeh A. The relationship of surface roughness and cell response of chemical surface modification of titanium. J Mater Sci. 2012;23:1479–88.
4. Nakagawa M, Matono Y, Matsuya S, Udoh K, Ishikawa K. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments. Biomaterials. 2005;26:2239–46.10.1016/j.biomaterials.2004.07.022 ↗
5. Luo R, Liu ZD, Yan FX, Kong Y, Zhang YT. The biocompatibility of hydroxyapatite film deposition on micro-arc oxidation Ti6Al4V alloy. Appl Surf Sci. 2013;266:57–61.10.1016/j.apsusc.2012.11.074 ↗
6. Martinesi M, Stio M, Treves C, Borgioli F. Biocompatibility studies of low temperature nitrided and collagen-I coated AISI 316L austenitic stainless steel. J Mater Sci. 2013;24:1501–13.
7. Li XY, Tang B, Ye JR. Fabrication of Zr and Zr-N surface alloying layers and hardness improvement of Ti–6Al–4V alloy by plasma surface alloying technique. Appl Surf Sci. 2012;258:1981–4.10.1016/j.apsusc.2011.05.083 ↗
8. Ye X, Kuang J, Li X, Tang G. Microstructure, properties and temperature evolution of electro-pulsing treated functionally graded Ti–6Al–4V alloy strip. J Alloy Compd. 2014;599:1–9.10.1016/j.jallcom.2014.02.055 ↗
9. Ye X, Li X, Song G, Tang G. Effect of recovering damage and improving microstructure in the titanium alloy strip under high-energy electropulses. J Alloy Compd. 2014;. doi:10.1016/j.jallcom.2014.07.143.10.1016/j.jallcom.2014.07.143 ↗
10. Ye X, Yang Y, Song G, Tang G. Enhancement of ductility, weakening of anisotropy behavior and local recrystallization in cold-rolled Ti-6Al-4V alloy strips by high-density electropulsing treatment. Appl Phys A. 2014;. doi:10.1007/s00339-014-8655-1.10.1007/s00339-014-8655-1 ↗
11. Sun YS, Chang JH, Huang HH. Corrosion resistance and biocompatibility of titanium surface coated with amorphous tantalum pentoxide. Thin Solid Films. 2013;528:130–5.10.1016/j.tsf.2012.06.088 ↗
12. Liu G, Lu J, Lu K. Surface nanocrystallization of 316L stainless steel induced by ultrasonic shot peening. Mat Sci Eng A. 2000;286:91–5.10.1016/S0921-5093(00)00686-9 ↗
13. Mordyuk BN, Prokopenko GI. Ultrasonic impact peening for the surface properties’ management. J Sound Vib. 2007;308:855–66.10.1016/j.jsv.2007.03.054 ↗
14. Allenstein U, Ma Y, Arabi-Hashemi A, Zink M, Mayr SG. Fe-Pd based ferromagnetic shape memory actuators for medical applications: biocompatibility, effect of surface roughness and protein coatings. Acta Biomater. 2013;9:5845–53.10.1016/j.actbio.2012.10.040 ↗
15. Wirth C, Comte V, Lagneau C, Exbrayat P, Lissac M, Jaffrezic-Renault N, Ponsonnet L. Nitinol surface roughness modulates in vitro cell response: a comparison between fibroblasts and osteoblasts. Mater Sci Eng C. 2005;25:51–60.10.1016/j.msec.2004.06.001 ↗
16. Wei CH, Pan WJ, Hung MS. The effects of substrate roughness and associated surface properties on the biocompatibility of diamond-like carbon films. Surf Coat Technol. 2013;224:8–17.10.1016/j.surfcoat.2013.02.038 ↗
17. Candan S, Turkmen M, Ahlatci H, Candan E. Corrosion resistance of powder injection moulded titanium in physiologic serum and artificial saliva. Acta Metall Sin. 2010;23:197–205.
18. Schiff N, Grosgogeat B, Lissac M, Dalard F. Influence of fluoridated mouthwashes on corrosion resistance of orthodontics wires. Biomaterials. 2004;25:4535–42.10.1016/j.biomaterials.2003.11.042 ↗
19. Schiff N, Grosgogeat B, Lissac M, Dalard F. Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys. Biomaterials. 2002;23:1995–2002.10.1016/S0142-9612(01)00328-3 ↗
20. Chou TS. Recrystallisation behaviour and grain structure in mechanically alloyed oxide dispersion strengthened MA956 steel. Mater Sci Eng A. 1997;223:78–90.10.1016/S0921-5093(96)10473-1 ↗
21. Lu YP, Molodov DA, Gottstein G. Recrystallization kinetics and microstructure evolution during annealing of a cold-rolled Fe-Mn-C alloy. Acta Mater. 2011;59:3229–43.10.1016/j.actamat.2011.01.063 ↗
22. Lei G, Guoyi T, Yanbin J, Chu PK. Texture evolution in cold-rolled AZ31 magnesium alloy during electropulsing treatment. J Alloy Compd. 2009;487:309–13.10.1016/j.jallcom.2009.07.180 ↗
23. Bailey J, Weber ER, Opsal J, Rosencwaig A. Nonthermal laser-induced recrystallization of amorphous-silicon. Phys Rev B. 1991;44:13116–9.10.1103/PhysRevB.44.13116 ↗
24. Bailey JM, Gwathmey AT. Dislocation arrays in depth and recrystallization produced by surface deformation of single crystals of copper at high temperature. J Appl Phys. 1960;31:215–7.10.1063/1.1735406 ↗
25. Xu Z, Tang G, Ding F, Tian S, Tian H. The effect of multiple pulse treatment on the recrystallization behavior of Mg-3Al-1Zn alloy strip. Appl Phys A. 2007;88:429–33.10.1007/s00339-007-4007-8 ↗
26. Jiang YB, Tang GY, Shek C, Zhu YH, Xu ZH. On the thermodynamics and kinetics of electropulsing induced dissolution of beta-Mg17Al12 phase in an aged Mg-9Al-1Zn alloy. Acta Mater. 2009;57:4797–808.10.1016/j.actamat.2009.06.044 ↗
27. Zhang ZM, Xu HY, Li BC. Corrosion properties of plastically deformed AZ80 magnesium alloy. Trans Nonferr Met Soc. 2010;202:S697–702.10.1016/S1003-6326(10)60565-1 ↗
28. Sharon JA, Zhang Y, Mompiou F, Legros M, Hemker KJ. Discerning size effect strengthening in ultrafine-grained Mg thin films. Scr Mater. 2014;75:10–3.10.1016/j.scriptamat.2013.10.016 ↗
29. Yang XJ, Zhou JX, Ling X. Study on plastic damage of AISI 304 stainless steel induced by ultrasonic impact treatment. Mater Des. 2012;36:477–81.10.1016/j.matdes.2011.11.023 ↗
30. Lee YH, Bhattarai G, Aryal S, Lee NH, Lee MH, Kim TG, Jhee EC, Kim HY, Yi HK. Modified titanium surface with gelatin nano gold composite increases osteoblast cell biocompatibility. Appl Surf Sci. 2010;256:5882–7.10.1016/j.apsusc.2010.03.069 ↗