journal article·2013-01

Artifact level produced by different femoral head prostheses in CT imaging: diamond coated silicon nitride as total hip replacement material

Simone P. Rodrigues, José M. Paiva, Silvia De Francesco, Margarida I. Amaral, Filipe J. Oliveira, Rui F. Silva

Publisher page

Abstract

Commercial femoral head prostheses (cobalt-chromium alloy, yttria partially stabilized zirconia (Y-PSZ) and alumina) and new silicon nitride ceramic ones (nanocrystalline diamond coated and uncoated) were compared in terms of artifact level production by computed tomography (CT). Pelvis examination by CT allows the correct diagnosis of some pathologies (e.g. prostate and colon cancer) and the evaluation of the prosthesis-bone interface in post-operative joint surgery. Artifact quantification is rarely seen in literature despite having a great potential to grade biomaterials according to their imaging properties. Materials' characteristics (density and effective atomic number), size and geometry of the prostheses can cause more or less artifact. A quantification procedure based on the calculation of four statistical parameters for the Hounsfield pixel values (mean, standard deviation, mean squared error and worst case error) is presented. CT sequential and helical scanning modes were performed. Results prove the artifact reproducibility and indicate that the cobalt-chromium and Y-PSZ are the most artifact-inducing materials, while alumina and silicon nitride (diamond coated and uncoated) ceramic ones present a low level of artifact. Considering the excellent biocompatibility and biotribological behaviour reported in earlier works, combined with the high medical imaging quality here assessed, diamond coated silicon nitride ceramics are arising as new materials for joint replacement.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced X-ray and CT Imaging · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Santavirta S, Böhler M, Harris WH, Konttinen YT, Lappalainen R, Muratoglu O, et al. Alternative materials to improve total hip replacement tribology. Acta Orthop Scand. 2003;74(4):380–8.10.1080/00016470310017668 ↗
2. Navarro M, Michiardi A, Castaño O, Planell JA. Biomaterials in orthopaedics. J R Soc Interface. 2008;5:1137–58.10.1098/rsif.2008.0151 ↗
3. Berg BV, Malghem J, Maldague B, Lecouvet F. Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware. Eur J Radiol. 2006;60:470–9.10.1016/j.ejrad.2006.08.008 ↗
4. Mitsuhashi S, Harada Y, Yanagawa N, Kamikawa K, Kitahara H, Moriya H. Automatic measurement of polyethylene modification in metal-backed artificial hip joints using three-dimensional CT. J Orthop Sci. 2004;9(1):10–5.10.1007/s00776-003-0744-5 ↗
5. Aubin M, Morin O, Chen J, Gillis A, Pickett B, Aubry JF, et al. The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement. Br J Radiol. 2006;79:918–21.10.1259/bjr/19559792 ↗
6. Yazdia M, Gingras L, Beaulieu L. An adaptative approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies. Int J Radiat Oncol Biol Phys. 2005;62(4):1224–31.10.1016/j.ijrobp.2005.02.052 ↗
7. Barret JF, Keat N. Artifacts in CT: recognition and avoidance. RadioGraphics. 2004;24:1679–91.10.1148/rg.246045065 ↗
8. Liu PT, Pavlicek WP, Peter MB, Spangehl MJ, Roberts CC, Paden RG. Metal artifact reduction image reconstruction algorithm for CT of implanted metal orthopedic devices: a work in progress. Skelet Radiol. 2009;38:797–802.10.1007/s00256-008-0630-5 ↗
9. Man BD, Nuyts J, Dupont P, Marchal G, Suetens P. Reduction of metal streak artifacts in X-ray computed tomography using a transmission maximum a posteriori algorithm. IEEE Trans Nucl Sci. 2000;47(3):977–81.10.1109/23.856534 ↗
10. Robertson DD, Yuan J, Wang G, Vannier MW. Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction. J Comput Assist Tomogr. 1997;21(2):293–8.10.1097/00004728-199703000-00024 ↗
11. Mazzocchi M, Bellosi A. On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part I: processing, microstructure, mechanical properties, cytotoxicity. J Mater Sci Mater Med. 2008;19:2881–7.10.1007/s10856-008-3417-2 ↗
12. Neumann A, Reske T, Held M, Jahnke K. Comparative investigation of the biocompatibility of various silicon nitride ceramic qualities in vitro. J Mater Sci Mater Med. 2004;15:1135–40.10.1023/B:JMSM.0000046396.14073.92 ↗
13. Abreu CS, Oliveira FJ, Belmonte M, Fernandes AJS, Gomes JR, Silva RF. CVD diamond coated silicon nitride self-mated systems: tribological behaviour under high loads. Tribol Lett. 2006;21(2):141–51.10.1007/s11249-006-9032-9 ↗
14. Amaral M, Abreu CS, Fernandes AJS, Oliveira FJ, Gomes JR, Silva RF. Nanodiamond-based tribosystems. Surf Coat Technol. 2010;204:1962–9.10.1016/j.surfcoat.2009.11.015 ↗
15. Guedes e Silva CC, König B, Carbonaric MJ, Yoshimoto M, Allegrini S, Bressiani JC. Bone growth around silicon nitride implants—an evaluation by scanning electron microscopy. Mater Charact. 2008;59:1339–41.10.1016/j.matchar.2007.11.007 ↗
16. Bal BS, Rahaman MN. Orthopedic applications of silicon nitride ceramics. Acta Biomater. 2012;8:2889–98.10.1016/j.actbio.2012.04.031 ↗
17. Sonntag R, Reinders J, Kretzer JP. What’s next? Alternative materials for articulation in total joint replacement. Acta Biomater. 2012;8:2434–41.10.1016/j.actbio.2012.03.029 ↗
18. Bal BS, Khandkar A, Lakshminarayanan R, Clarke I, Hoffman AA, Rahaman MN. Fabrication and testing of silicon nitride bearings in total hip arthroplasty: winner of the 2007 “HAP” PAUL Award. J Arthroplast. 2009;24(1):110–6.10.1016/j.arth.2008.01.300 ↗
19. Amaral M, Abreu CS, Oliveira FJ, Gomes JR, Silva RF. Tribological characterization of NCD in physiological fluids. Diam Relat Mater. 2008;17:848–52.10.1016/j.diamond.2007.12.070 ↗
20. Amaral M, Gomes PS, Lopes MA, Santos JD, Silva RF, Fernandes MH. Nanocrystalline diamond as a coating for joint implants: cytotoxicity and biocompatibility assessment. J Nanomater. 2008;2008:1–9.10.1155/2008/894352 ↗
21. Amaral M, Gomes PS, Lopes MA, Santos JD, Silva RF, Fernandes MH. Cytotoxicity evaluation of nanocrystalline diamond coatings by fibroblast cell cultures. Acta Biomater. 2009;5:755–63.10.1016/j.actbio.2008.08.015 ↗
22. Kim HK, Kum O, Max NL. Computer-aided CT image analysis based on clustered hounsfield values. J Korean Phys Soc. 2007;51(1):235–44.10.3938/jkps.51.235 ↗
23. Coolens C, Childs PJ. Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale. Phys Med Biol. 2003;48(1591):1603.
24. Siemens (2005) AG Medical Solutions—Somatom sensation 40/64 application guide.
25. Seredy C, Zeiger S, AMEDICA/US SPINE® Enters the reconstructive surgery market—First silicon nitride total hip replacement. http://amedica.com/company/news/02.17.11.pdf . Accessed July 2011.