journal article·2015-11Open access

An electro-responsive hydrogel for intravascular applications: an in vitro and in vivo evaluation

Peter Verbrugghe, Jelle Verhoeven, Walter Coudyzer, Eric Verbeken, Peter Dubruel, Eduardo Mendes, Frank Stam, Bart Meuris, Paul Herijgers

Abstract

There is a growing interest in using hydrogels for biomedical applications, because of more favourable characteristics. Some of these hydrogels can be activated by using particular stimuli, for example electrical fields. These stimuli can change the hydrogel shape in a predefined way. It could make them capable of adaptation to patient-specific anatomy even post-implantation. This is the first paper aiming to describe in vivo studies of an electro-responsive, Pluronic F127 based hydrogel, for intravascular applications. Pluronic methacrylic acid hydrogel (PF127/MANa) was in vitro tested for its haemolytic and cytotoxic effects. Minimal invasive implantation in the carotid artery of sheep was used to evaluate its medium-term biological effects, through biochemical, macroscopic, radiographic, and microscopic evaluation. Indirect and direct testing of the material gave no indication of the haemolytic effects of the material. Determination of fibroblast viability after 24 h of incubation in an extract of the hydrogel showed no cytotoxic effects. Occlusion was obtained within 1 h following in vivo implantation. Evaluation at time of autopsy showed a persistent occlusion with no systemic effects, no signs of embolization and mild effects on the arterial wall. An important proof-of-concept was obtained showing biocompatibility and effectiveness of a pluronic based electro-responsive hydrogel for obtaining an arterial occlusion with limited biological impact. So the selected pluronic-methacrylic acid based hydrogel can be used as an endovascular occlusion device. More importantly it is the first step in further development of electro-active hydrogels for a broad range of intra-vascular applications (e.g. system to prevent endoleakage in aortic aneurysm treatment, intra-vascular drug delivery).
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Intracranial Aneurysms: Treatment and Complications · Hydrogels: synthesis, properties, applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Oztop HNSD, Solpan D, Guven O. Adsorption of BSA onto radiation-crosslinked poly(AAm/HPMA/MA) terpolymers. Polym Bull. 2003;50:183–90.10.1007/s00289-003-0152-1 ↗
2. Smith EA, Oehme FW. Acrylamide and polyacrylamide: a review of production, use, environmental fate and neurotoxicity. Rev Environ Health. 1991;9(4):215–28.10.1515/REVEH.1991.9.4.215 ↗
3. de Cassia Novaes W, Berg A. Experiences with a new nonbiodegradable hydrogel (Aquamid): a pilot study. Aesthet Plast Surg. 2003;27(5):376–80. doi: 10.1007/s00266-003-2119-x .10.1007/s00266-003-2119-x ↗
4. Shipp ALG, Gentry R, McDonald T, Bartow H, Bounds J, Macdonald N, Clewell H, Allen B, Van Landingham C. Acrylamide: review of toxicity data and dose-response analyses for cancer and noncancer effects. Crit Rev Toxicol. 2006;36(6–7):481–608.10.1080/10408440600851377 ↗
5. Liu ZSRG. Preparation of superabsorbent polymers by crosslinking acrylic acid and acrylamide copolymers. J Appl Polym. 1996;64:1345–53.
6. Bromberg L, Temchenko M, Alakhov V, Hatton TA. Bioadhesive properties and rheology of polyether-modified poly(acrylic acid) hydrogels. Int J Pharm. 2004;282(1–2):45–60. doi: 10.1016/j.ijpharm.2004.05.030S0378517304003291 .10.1016/j.ijpharm.2004.05.030 ↗
7. Greytak ABGA, Tanaka T. Shape imprinting due to variable disulfide bonds in polyacrylamide gels. J Chem Phys. 2001;114:10551–7.10.1063/1.1369139 ↗
8. Hon YCLM, Xue WM, Zhou X. A new formulation and computation of the triphasic model for mechano-electrochemical mixtures. Comput Mech. 1999;24:155–65.10.1007/s004660050448 ↗
9. Pons J. Emerging Actuator Technologies: A Micromechatronic Aproach. Chichester: Wiley; 2005.10.1002/0470091991 ↗
10. Murdan S. Electro-responsive drug delivery from hydrogels. J Controll Release. 2003;92(1–2):1–17.10.1016/S0168-3659(03)00303-1 ↗
11. Kallmes DF, Fujiwara NH. New expandable hydrogel-platinum coil hybrid device for aneurysm embolization. AJNR Am J Neuroradiol. 2002;23(9):1580–8.
12. Bearat HH, Preul MC, Vernon BL. Cytotoxicity, in vitro models and preliminary in vivo study of dual physical and chemical gels for endovascular embolization of cerebral aneurysms. J Biomed Mater Res A. 2013;101(9):2515–25. doi: 10.1002/jbm.a.34554 .10.1002/jbm.a.34554 ↗
13. Glazer PJ, Verbrugghe P, Adesanya K, Herijgers P, Dubruel P, Mendes E. Electro-actuation of biocompatible pluronic/methacrylic acid hydrogel in blood-plasma and in blood-mimicking buffers. RSC Adv. 2014;4(4):1890–4. doi: 10.1039/C3ra45395b .10.1039/C3RA45395B ↗
14. ASTM. ASTM international - Designation: F 756 - 08. Standard practice for assessment of hemolytic properties of materials: ASTM International, West Conshohocken; 2008.
15. Stadie WC. A method for the determination of methemoglobin in whole blood. J Biol Chem. 1920;41:237.10.1016/S0021-9258(18)87221-0 ↗
16. 10993-5 I. Biological evaluation of medical devices. Part 5. Test for in vitro cytotoxicity. 2009.
17. Denizot F, Lang R. Rapid colorimetric assay for cell growth and survival. Modifications to the tetrazolium dye procedure giving improved sensitivity and reliability. J Immunol Methods. 1986;89(2):271–7.10.1016/0022-1759(86)90368-6 ↗
18. Mosmann T. Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays. J Immunol Methods. 1983;65(1–2):55–63.10.1016/0022-1759(83)90303-4 ↗
19. Refojo MF. Hydrophobic interaction in poly(2-hydroxyethyl methacrylate) homogeneous hydrogel. J Polym Sci A. 1967;5(12):3103–13. doi: 10.1002/pol.1967.150051211 .10.1002/pol.1967.150051211 ↗
20. Ding JD, Duan SF, Zhu W, Yu L. Negative cooperative effect of cytotoxicity of a di-component initiating system for a novel injectable tissue engineering hydrogel. Chin Sci Bull. 2005;50(11):1093–6. doi: 10.1360/982004-459 .10.1360/982004-459 ↗
21. Mowery KA, Schoenfisch MH, Saavedra JE, Keefer LK, Meyerhoff ME. Preparation and characterization of hydrophobic polymeric films that are thromboresistant via nitric oxide release. Biomaterials. 2000;21(1):9–21.10.1016/S0142-9612(99)00127-1 ↗
22. Klee D, Höcker H. Polymers for biomedical applications: imrovement of the interface compatibility. Adv Polym Sci. 1999;149:1–57.10.1007/3-540-48838-3_1 ↗
23. Paravastu SC, Jayarajasingam R, Cottam R, Palfreyman SJ, Michaels JA, Thomas SM. Endovascular repair of abdominal aortic aneurysm. Cochrane Database Syst Rev. 2014;. doi: 10.1002/14651858.CD004178.pub2 .
24. Servant A, Leon V, Jasim D, Methven L, Limousin P, Fernandez-Pacheco EV, et al. Graphene-based electroresponsive scaffolds as polymeric implants for on-demand drug delivery. Adv Healthc Mater. 2014;3(8):1334–43. doi: 10.1002/adhm.201400016 .10.1002/adhm.201400016 ↗
25. Indermun S, Choonara YE, Kumar P, Du Toit LC, Modi G, Luttge R, et al. Patient-controlled analgesia: therapeutic interventions using transdermal electro-activated and electro-modulated drug delivery. J Pharm Sci. 2014;103(2):353–66. doi: 10.1002/jps.23829 .10.1002/jps.23829 ↗