Characterization of polyurethane-based synthetic vertebrae for spinal cement augmentation training
Source abstract
Abstract
Vertebral augmentation techniques are used to stabilize impacted vertebrae. To minimize intraoperative risks, a solid education of surgeons is desirable. Thus, to improve education of surgeons as well as patient safety, the development of a high-fidelity simulator for the surgical training of cement augmentation techniques was initiated. The integrated synthetic vertebrae should be able to provide realistic haptics during all procedural steps. Synthetic vertebrae were developed, tested and validated with reference to human vertebrae. As a further reference, commercially available vertebrae surrogates for orthopedic testing were investigated. To validate the new synthetic vertebrae, characteristic mechanical parameters for tool insertion, balloon dilation pressure and volume were analyzed. Fluoroscopy images were taken to evaluate the bone cement distribution. Based on the measurement results, one type of synthetic vertebrae was able to reflect the characteristic parameters in comparison to human vertebrae. The different tool insertion forces (19.7 ± 4.1, 13.1 ± 0.9 N, 1.5 ± 0.2 N) of the human reference were reflected by one bone surrogate (11.9 ± 9.8, 24.3 ± 3.9 N, 2.4 ± 1.0 N, respectively). The balloon dilation pressure (13.0 ± 2.4 bar), volume (2.3 ± 1.5 ml) of the synthetic vertebrae were in good accordance with the human reference (10.7 ± 3.4 bar, 3.1 ± 1.1 ml). Cement application forces were also in good accordance whereas the cement distribution couldn't be reproduced accurately. Synthetic vertebrae were developed that delivered authentic haptics during transpedicular instrument insertion, balloon tamp dilation and bone cement application. The validated vertebra model will be used within a hybrid simulator for minimally invasive spine surgery to educate and train surgeons.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Spinal Fractures and Fixation Techniques · Spine and Intervertebral Disc Pathology · Surgical Simulation and Training
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. Svedbom A, Hernlund E, Ivergård M, Compston J, Cooper C, Stenmark J. et al. Osteoporosis in the European Union: a compendium of country-specific reports. Arch Osteoporos. 2013;8:1–2. https://doi.org/10.1007/s11657-013-0137-0 .10.1007/s11657-013-0137-0 ↗
2. Wasnich RD. Vertebral fracture epidemiology. Bone. 1996;18 (3 Suppl):179S–83S. https://doi.org/10.1016/8756-3282(95)00499-810.1016/8756-3282(95)00499-8 ↗
3. Garfin SR, Reilley MA. Minimally invasive treatment of osteoporotic vertebral body compression fractures. Spine J. 2002;2:76–80.10.1016/S1529-9430(01)00166-8 ↗
4. Mathis JM, Wong W. Percutaneous vertebroplasty: technical considerations. J Vasc Interv Radiol. 2003;14:953–60. https://doi.org/10.1097/01.RVI.0000083255.29749.A8 . http://www.sciencedirect.com/science/article/pii/S105104430760433310.1097/01.RVI.0000083255.29749.A8 ↗
5. Mathis JM, Orlando Ortiz A, Zoarski GH. Vertebroplasty versus kyphoplasty: a comparison and contrast. Percutaneous Vertebroplasty and Kyphoplasty (2006) 145–56. https://doi.org/10.1007/0-387-36083-2_9 .10.1007/0-387-36083-2_9 ↗
6. Lee JY, Lim MR, Ludwig SC, Elias I, Kuklo TR, Vaccaro AR. Vertebroplasty and kyphoplasty for vertebral compression fractures. Semin Spine Surg. 2005;17 (3 SPEC. ISS.):158–64. https://doi.org/10.1053/j.semss.2005.06.003 . http://linkinghub.elsevier.com/retrieve/pii/S104073830500039010.1053/j.semss.2005.06.003 ↗
7. Hardouin D, Fayada P, Leclet P, Chopin G. Kyphoplasty. Jt Bone Spine. 2002;69:256–61.10.1016/S1297-319X(02)00390-1 ↗
8. Dubrowski A, Brydges R, Satterthwaite L, Xeroulis G, Classen R. Do not teach me while I am working! Am J Surg. 2012;203:253–7. https://doi.org/10.1016/j.amjsurg.2010.08.020 . http://www.ncbi.nlm.nih.gov/pubmed/2226965710.1016/j.amjsurg.2010.08.020 ↗
9. Botden J, Torab S, Buzink F, Jakimowicz S. The importance of haptic feedback in laparoscopic suturing training and the additive value of virtual reality simulation. Surg Endosc. 2008;5:1214–22.10.1007/s00464-007-9589-x ↗
10. Seymour N, Gallagher G, Roman S, OBrien M, Bansal V, Andersen D. et al. Virtual reality training improves operating room performance: results of a randomized, double-blinded study. Ann Surg. 2002;236:458–63.10.1097/00000658-200210000-00008 ↗
11. Grantcharov T, Kristiansen V, Bendix J, Bardram L, Rosenberg J, Funch-Jensen P. Randomized clinical trail of virtual reality simulation for laparoscopic skills training. Brit J Surg. 2004;91:146–50.10.1002/bjs.4407 ↗
12. Van Sickle K. Construct validation of the promis simulator using a novel laparoscopic suturing task. Surg Endosc. 2005;19:1227–31.10.1007/s00464-004-8274-6 ↗
13. Aggarwal R, Moorthy K, Darzi A. Laparoscopic skills training and assessment. Brit J Surg. 2004;91:1549–58.10.1002/bjs.4816 ↗
14. Ström P, Hedman L, Särnå L, Kjellin A, Wredmark T, Felländer-Tsai L. Early exposure to haptic feedback enhances performance in surgical simulator training: a prospective randomized crossover study in surgical residents. Surg Endosc Other Interv Tech. 2006;20:1383–8. https://doi.org/10.1007/s00464-005-0545-3 . http://www.ncbi.nlm.nih.gov/pubmed/1682365210.1007/s00464-005-0545-3 ↗
15. Nackman GB, Bermann M, Hammond J. Effective use of human simulators in surgical education1. J Surg Res. 2003;115:214–8. https://doi.org/10.1016/S0022-4804(03)00359-7 . http://linkinghub.elsevier.com/retrieve/pii/S002248040300359710.1016/S0022-4804(03)00359-7 ↗
16. Fuerst D, Hollensteiner M, Schrempf A. A novel augmented reality simulator for minimally invasive spine surgery, Proc. 2014 Summer Simul Multiconference. (2014) 28:1–28:5.10.1109/EMBC.2014.6943639 ↗
17. Hollensteiner M, Fuerst D, Schrempf A. Artificial vertebrae for a novel simulator in minimally invasive spine surgery. Biomed Tech. 2013;58 (Suppl. 1):4409–10. https://doi.org/10.1515/bmt-2013-410.1515/bmt-2013-4 ↗
18. Hollensteiner M, Fuerst D, Schrempf A. Artificial muscles for a novel simulator in minimally invasive spine surgery. Biomed Tech. 2014;58 (Suppl. 1):4409–10. https://doi.org/10.1515/bmt-2013-410.1515/bmt-2013-4 ↗
19. Hollensteiner M, Samrykit M, Hess M, Fuerst D, Schrempf A. Development of Trabecular Bone Surrogates for Kyphoplasty-Balloon Dilatation Training, Proc Annu Int Conf IEEE Eng Med Biol Soc EMBS. 2015; 2–5.10.1109/EMBC.2015.7319540 ↗
20. Püschel K. Lehre und forschung an verstorbenen. Rechtsmedizin. 2016;26:115–9.10.1007/s00194-016-0087-0 ↗
21. Hollensteiner M, Fürst D, Augat P, Esterer B, Schrödl F, Gabauer S. et al. Procedure-specific validation of artificial vertebrae. IEEE Trans Biomed Eng. 2018;65:1852–8. https://doi.org/10.1109/TBME.2017.2782797 .10.1109/TBME.2017.2782797 ↗
22. Hollensteiner M, Samrykit M, Hess M, Fuerst D, Esterer B, Schrempf A, Inexpensive bone cement substitute for vertebral cement augmentation training, In: Engineering in Medicine and Biology Society (EMBC), 2016 IEEE 38th Annual International Conference of the, IEEE, 2016, pp. 2202–5.10.1109/EMBC.2016.7591166 ↗
23. Loeffel M, Ferguson SJ, Nolte L-P, Kowal JH. Vertebroplasty: experimental characterization of polymethylmethacrylate bone cement spreading as a function of viscosity, bone porosity, and flow rate. Spine. 2008;33:1352–9. https://doi.org/10.1097/BRS.0b013e3181732aa910.1097/BRS.0b013e3181732aa9 ↗
24. Faul F, Erdfelder E, Lang A-G, Buchner A. G* power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39:175–91.10.3758/BF03193146 ↗
25. Cole JH, Van Der Meulen MCH. Whole bone mechanics and bone quality. Clin Orthop Relat Res. 2011;469:2139–49. https://doi.org/10.1007/s11999-011-1784-310.1007/s11999-011-1784-3 ↗
26. Mobbs RJ, Sivabalan P, Li J. Technique, challenges and indications for percutaneous pedicle screw fixation. J Clin Neurosci. 2011;18:741–9. https://doi.org/10.1016/j.jocn.2010.09.01910.1016/j.jocn.2010.09.019 ↗
27. Mughir AMA, Yusof MI, Abdullah S, Ahmad S. Morphological comparison between adolescent and adult lumbar pedicles using computerised tomography scanning. Surg Radiol Anat. 2010;32:587–92.10.1007/s00276-009-0612-x ↗
28. Cui W, Liu B, Wang L, Kang W, Chen B. The correlation analysis of balloon volume and bone cement volume in percutaneous kyphoplasty. Zhonghua Wai Ke Za Zhi. 2015;53:289–93.
29. Groen RJ, du Toit DF, Phillips FM, Hoogland PV, Kuizenga K, Coppes MH. et al. Anatomical and pathological considerations in percutaneous vertebroplasty and kyphoplasty: a reappraisal of the vertebral venous system. Spine. 2004;29:1465–71.10.1097/01.BRS.0000128758.64381.75 ↗