Mixed ceramic combinations in primary total hip arthroplasty achieved reassuring mid-to-longterm outcomes
Source abstract
Abstract
Introduction Ceramic-on-ceramic couplings demonstrated to be reliable bearings in primary total hip arthroplasty (THA), with long-term remarkable results. Like-on-like configurations were widely described. On the contrary, mixed material combinations from the same manufacturer, Delta-on-Forte or Forte-on-Delta, were poorly studied. In particular, it is unknown whether mixed ceramic combinations are more at risk of ceramic fractures. Thus, a registry study was conducted to investigate the long-term survival rates and reasons for revision of mixed ceramic combinations. A comparison with Delta-on-Delta couplings was also performed. Materials and methods The regional arthroplasty registry RIPO was enquired about three cohorts of ceramic bearings (head-on-liner: Delta-on-Forte, Forte-on-Delta, Delta-on-Delta). Demographics, survival rates and reasons for revision were evaluated and compared. Results In total, 346 (1.5%) implants had a Delta-on-Forte coupling (mean follow-up: 6.4 years). In total, 1163 (5%) THAs had a Forte-on-Delta articulation (mean follow-up: 8.2 years). Delta-on-Delta surfaces were implanted in 21,874 (93.5%) hips (mean follow-up: 3.9 years). Mixed material combinations were implanted between 2003 and 2007. The survival rates of the three cohorts were similar and were higher than 95% at 10 years. In Forte-on-Delta group, four liners failed (0.3% of the implants), whereas ceramic fractures occurred in 15 cases (0.1%) in Delta-on-Delta couplings (3 heads and 12 liners). Considering ceramic fracture as endpoint, there was no significant difference between the three survival rates. Conclusions Mixed ceramic bearing configurations from the same manufacturer in primary THA showed mid-to-longterm dependable outcomes, not inferior to the most recent like-on-like ceramic bearings. No additional risks of ceramic fractures were evident. Thus, closer follow-ups are not required.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. Yoon PW, Yoo JJ, Kim Y, Yoo S, Lee S, Kim HJ. The epidemiology and national trends of bearing surface usage in primary total hip arthroplasty in Korea. Clin Orthop Surg. 2016;8:29–37.10.4055/cios.2016.8.1.29 ↗
2. Choy WS, Cha YH, Jeon CY, Lee KS, Kim HY. A Minimum ten years of follow-up of alumina head on delta liner total hip arthroplasty. J Arthroplast. 2018;33:470–6.10.1016/j.arth.2017.08.043 ↗
3. Kurtz SM, Kocagöz S, Arnholt C, Huet R, Ueno M, Walter WL. Advances in zirconia toughened alumina biomaterials for total joint replacement. J Mech Behav Biomed Mater. 2014;31:107–16.10.1016/j.jmbbm.2013.03.022 ↗
4. Toni A, Giardina F, Guerra G, Sudanese A, Montalti M, Stea S, Bordini B 3rd. generation alumina-on-alumina in modular hip prosthesis: 13 to 18 years follow-up results. Hip Int. 2017;27:8–13.10.5301/hipint.5000429 ↗
5. Blakeney WG, Beaulieu Y, Puliero B, Lavigne M, Roy A, Massé V, Vendittoli PA. Excellent results of large-diameter ceramic-on-ceramic bearings in total hip arthroplasty. Bone Jt J. 2018;100-B:1434–41.10.1302/0301-620X.100B11.BJJ-2018-0532.R1 ↗
6. Lim SJ, Ryu HG, Eun HJ, Park CW, Kwon KB, Park YS. Clinical outcomes and bearing-specific complications following fourth-generation alumina ceramic-on-ceramic total hip arthroplasty: a single-surgeon series of 749 hips at a minimum of 5-year follow-up. J Arthroplast. 2018;33:2182–2186.e1.10.1016/j.arth.2018.02.045 ↗
7. Buttaro MA, Zanotti G, Comba FM, Piccaluga F. Primary total hip arthroplasty with fourth-generation ceramic-on-ceramic: analysis of complications in 939 consecutive cases followed for 2-10 years. J Arthroplast. 2017;32:480–6.10.1016/j.arth.2016.07.032 ↗
8. Registro dell’implantologia protesica ortopedica. https://ripo.cineca.it/. Accessed 22 Nov 2018.
9. Bordini B, Stea S, Castagnini F, Busanelli L, Giardina F, Toni A. The influence of bearing surfaces on periprosthetic hip infections: analysis of thirty nine thousand, two hundred and six cementless total hip arthroplasties. Int Orthop. 2019;43:103–9.10.1007/s00264-018-4097-2 ↗
10. Giardina F, Castagnini F, Stea S, Bordini B, Montalti M, Toni A. Short stems versus conventional stems in cementless total hip arthroplasty: A Long-Term Registry Study. J Arthroplast. 2018;33:1794–9.10.1016/j.arth.2018.01.005 ↗
11. Traina F, De Fine M, Bordini B, Toni A. Risk factors for ceramic liner fracture after total hip arthroplasty. Hip Int. 2012;22:607–14.10.5301/HIP.2012.10339 ↗
12. Lombardi AV Jr, Berend KR, Seng BE, Clarke IC, Adams JB. Delta ceramic-on-alumina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis. Clin Orthop Relat Res. 2010;468:367–74.10.1007/s11999-009-1143-9 ↗
13. Kang BJ, Ha YC, Hwang SC, Lee YK, Koo KH. Midterm results of large diameter Biolox forte ceramic head on delta ceramic liner articulation in total hip arthroplasty. J Arthroplast. 2014;29:2412–4.10.1016/j.arth.2014.03.003 ↗
14. Al-Hajjar M, Carbone S, Jennings LM, Begand S, Oberbach T, Delfosse D, Fisher J. Wear of composite ceramics in mixed-material combinations in total hip replacement under adverse edge loading conditions. J Biomed Mater Res B Appl Biomater. 2017;105:1361–8.10.1002/jbm.b.33671 ↗
15. Madanat R, Laaksonen I, Graves SE, Lorimer M, Muratoglu O, Malchau H. Ceramic bearings for total hip arthroplasty are associated with a reduced risk of revision for infection. Hip Int. 2018;28:222–6.10.1177/1120700018776464 ↗
16. Stanat SJ, Capozzi JD. Squeaking in third- and fourth-generation ceramic-on-ceramic total hip arthroplasty: meta-analysis and systematic review. J Arthroplast. 2012;27:445–53.10.1016/j.arth.2011.04.031 ↗
17. Traina F, De Fine M, Di Martino A, Faldini C. Fracture of ceramic bearing surfaces following total hip replacement: a systematic review. Biomed Res Int. 2013;2013:157247.10.1155/2013/157247 ↗