Abstract

PDMS is widely used for prosthetic device manufacture. Conventional ion implantation is not a suitable treatment to enhance the biocompatibility of poly dimethyl siloxane (PDMS) due to its propensity to generate a brittle silicon oxide surface layer which cracks and delaminates. To overcome this limitation, we have developed new plasma based processes to balance the etching of carbon with implantation of carbon from the plasma source. When this carbon was implanted from the plasma phase it resulted in a surface that was structurally similar and intermixed with the underlying PDMS material and not susceptible to delamination. The enrichment in surface carbon allowed the formation of carbon based radicals that are not present in conventional plasma ion immersion implantation (PIII) treated PDMS. This imparts the PDMS surfaces with covalent protein binding capacity that is not observed on PIII treated PDMS. The change in surface energy preserved the function of bound biomolecules and enhanced the attachment of MG63 osteosarcoma cells compared to the native surface. The attached cells, an osteoblast interaction model, showed increased spreading on the treated over untreated surfaces. The carbon-dependency for these beneficial covalent protein and cell linkage properties was tested by incorporating carbon from a different source. To this end, a second surface was produced where carbon etching was balanced against implantation from a thin carbon-based polymer coating. This had similar protein and cell-binding properties to the surfaces generated with carbon inclusion in the plasma phase, thus highlighting the importance of balancing carbon etching and deposition. Additionally, the two effects of protein linkage and bioactivity could be combined where the cell response was further enhanced by covalently tethering a biomolecule coating, as exemplified here with the cell adhesive protein tropoelastin. Providing a balanced carbon source in the plasma phase is applicable to prosthetic device fabrication as illustrated using a 3-dimensional PDMS balloon prosthesis for spinal implant applications. Consequently, this study lays the groundwork for effective treatments of PDMS to selectively recruit cells to implantable PDMS fabricated biodevices.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Electrospun Nanofibers in Biomedical Applications · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Meacham KW, Giuly RJ, Guo L, Hochman S, DeWeerth SP. A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cord. Biomed Micro. 2008;10:259–69.10.1007/s10544-007-9132-9 ↗
2. Diwan AD United Stated patent number US 2011/0153021 A1.
3. Strange DG, Fisher ST, Boughton PC, Kishen TJ, Diwan AD. Restoration of compressive loading properties of lumbar discs with a nucleus implant-a finite element analysis study. Spine J. 2010;10:602–9.10.1016/j.spinee.2010.04.015 ↗
4. Hillborg H, Gedde UW. Hydrophobicity changes in silicone rubbers. IEEE Trans Dielectr Electr Insul. 1999;6:703–17.10.1109/94.798127 ↗
5. Binfield TL, Colton E, Anderson JM. Fibroblast simulation by monocytes cultured in protein adsorbed biomedical polymers. I J Biomed Mater Res. 1991;25:165–75.10.1002/jbm.820250204 ↗
6. Tang LP, Eaton JW. Fibrinogen mediates acute inflammatory responses to biomaterials. Curr Opin Solid State Mater Sci. 2001;5:185–91.10.1016/S1359-0286(01)00007-9 ↗
7. Chen H, Yuan L, Song W, Wu ZK, Li D. Biocompatible polymer materials: role of protein-surface interactions. Prog Polym, Sci. 2008;33:1059–87.10.1016/j.progpolymsci.2008.07.006 ↗
8. Hirsh SL, McKenzie DR, Nosworthy NJ, Denman JA, Sezerman OU, Bilek MMM. The Vroman effect: competitive protein exchange with dynamic multilayer protein aggregates. Colloids Surf, B. 2013;103:395–404.10.1016/j.colsurfb.2012.10.039 ↗
9. Di Risio S, Yan N. Adsorption and inactivation behavior of horseradish peroxidase on various substrates. Colloids Surf, B. 2010;79:397–402.10.1016/j.colsurfb.2010.05.004 ↗
10. Llobera A, Wilke R, Büttgenbach S. Enhancement of the response of poly(dimethylsiloxane) hollow prisms through air mirrors for absorbance-based sensing. Talanta. 2008;75:473–9.10.1016/j.talanta.2007.11.041 ↗
11. Yasukawa T, Maekawa E, Mizutani F. Immobilization of glucose oxidase on a poly(dimethylsiloxane layer by using poly(L-lysine) as a polymer backbone. Anal Sci. 2009;25:1159–62.10.2116/analsci.25.1159 ↗
12. Wong I, Ho CM. Surface molecular property modifications for poly(dimethylsiloxane) (PDMS) based microfluidic devices. Microfluid Nanofluid. 2009;7:291–306.10.1007/s10404-009-0443-4 ↗
13. Makamba H, Kim JH, Lim K, Park N, Hahn JH. Surface modification of poly(dimethyl siloxane) microchannels. Electrophoresis. 2003;24:3607–19.10.1002/elps.200305627 ↗
14. Pruden KG, Beaudoin SP. Downstream microwave ammonia plasma treatment of polydimethylsiloxane. J Vac Sci Technol A. 2005;23:208.10.1116/1.1842131 ↗
15. Hillborg H, Gedde UW. Hydrophobicity recovery of polydimethylsiloxane after exposure to corona discharges. Polymer. 1998;39:1991–8.10.1016/S0032-3861(97)00484-9 ↗
16. Bax DV, McKenzie DR, Weiss AS, Bilek MMM. The linker-free covalent attachment of collagen to plasma immersion ion implantation treated polytetrafluoroethylene and subsequent cell-binding activity. Biomaterials. 2010;31:2526–34.10.1016/j.biomaterials.2009.12.009 ↗
17. Bilek MM, Bax DV, Kondyurin A, Yin Y, Nosworthy NJ, Fisher K, Waterhouse A, Weiss AS, dos Remedios CG, McKenzie DR. Free radical functionalization of surfaces to prevent adverse responses to biomedical devices. Proc Natl Acad Sci USA. 2011;108:14405–10.10.1073/pnas.1103277108 ↗
18. Bax DV, Kondyurin A, Waterhouse A, McKenzie DR, Weiss AS, Bilek MM. Surface plasma modification and tropoelastin coating of a polyurethane co-polymer for enhanced cell attachment and reduced thrombogenicity. Biomaterials. 2014;35:6797–809.10.1016/j.biomaterials.2014.04.082 ↗
19. Nosworthy NJ, McKenzie DR, Bilek MM. A new Surface for immobilizing and maintaining the function of enzymes in a freeze-dried state. Biomacromolecules. 2009;10:2577–83.10.1021/bm900523m ↗
20. Awaja F, Bax DV, Zhang S, James N, McKenzie DR. Cell adhesion to PEEK treated by plasma immersion ion implantation and deposition for active medical implants. Plasma Process Polym. 2012;9:355–62.10.1002/ppap.201100034 ↗
21. Bax DV, Wang Y, Li Z, Maitz PK, McKenzie DR, Bilek MM, Weiss AS. Binding of the cell adhesive protein tropoelastin to PTFE through plasma immersion ion implantation treatment. Biomaterials. 2011;32:5100–11.10.1016/j.biomaterials.2011.03.079 ↗
22. Yeo GC, Kondyurin A, Kosobrodova E, Weiss AS, Bilek MM. A sterilizable, biocompatible, tropoelastin surface coating immobilized by energetic ion activation. J R Soc Interface. 2017;14:20160837.10.1098/rsif.2016.0837 ↗
23. Hajian H, Wise SG, Bax DV, Kondyurin A, Waterhouse A, Dunn LL, Kielty CM, Yu Y, Weiss AS, Bilek MM, Bannon PG, Ng MK. Immobilisation of a fibrillin-1 fragment enhances the biocompatibility of PTFE. Colloids Surf, B. 2014;116:544–52.10.1016/j.colsurfb.2014.01.042 ↗
24. Bax DV, McKenzie DR, Bilek MM, Weiss AS. Directed cell attachment by tropoelastin on masked plasma immersion ion implantation treated PTFE. Biomaterials. 2011;32:6710–8.10.1016/j.biomaterials.2011.05.060 ↗
25. Rodgers UR, Weiss AS. Integrin alpha v beta 3 binds a unique non-RGD site near the C-terminus of human tropoelastin. Biochimie. 2004;86:173–8.10.1016/j.biochi.2004.03.002 ↗
26. Gioia G, Ortiz M. Delamination of Compressed Thin Films. Adv Appl Mech. 1997;33:120–92.
27. Bilek MMM, McKenzie DR. Plasma modified surfaces for covalent immobilization of functional biomolecules in the absence of chemical linkers: towards better biosensors and a new generation of medical implants. Biophys Rev. 2010;2:55–65.10.1007/s12551-010-0028-1 ↗
28. Lee P, Bax DV, Bilek MMM, Weiss AS. A novel cell adhesion region in tropoelastin mediates attachment to integrin αVβ5. J Biol Chem. 2014;289:1467–77.10.1074/jbc.M113.518381 ↗
29. Lee P, Yeo GC, Weiss AS. A cell adhesive peptide from tropoelastin promotes sequential cell attachment and spreading via distinct receptors. FEBS J. 2017;284:2216–30.10.1111/febs.14114 ↗
30. Yu Y, Wise SG, Michael PL, Bax DV, Yuen GS, Hiob MA, Yeo GC, Filipe EC, Dunn LL, Chan KH, Hajian H, Celermajer DS, Weiss AS, Ng MK. Characterization of endothelial progenitor cell interactions with human tropoelastin. PLoS ONE. 2015;10:e0131101.10.1371/journal.pone.0131101 ↗
31. Broekelmann TJ, Kozel BA, Ishibashi H, Werneck CC, Keeley FW, Zhang L, Mecham RP. Tropoelastin interacts with cell-surface glycosaminoglycans via its COOH-terminal domain. J Biol Chem. 2005;280:40939–47.10.1074/jbc.M507309200 ↗