journal article·2017-02

Biocompatibility study of three distinct carbon pastes for application as electrode material in neural stimulations and recordings

Melinda Varga, Paul Wolff, Klaus-Juergen Wolter

Publisher page

Abstract

Neural interfaces hold great promise for research and treatment of a wide variety of neurological diseases. Medical electrodes are designed to interface with the nervous system and provide control signals for neural prostheses. We fabricated previously a hook-up neural electrode. Here we investigate the in vitro cytotoxicity of three commercial carbon pastes used for printing the conductor tracks of this electrode. At first, the carbon pastes were characterized with respect to their microstructure and chemical composition. SEM images showed a grainy texture that is associated to the carbon/graphite microparticles dispersed by the polymeric binder. All the three pastes contained in major proportions carbon and in different proportions other elements. The surface roughness analysis evidenced differences in the smoothness of the carbon paste surfaces. Sterilization procedures did not alter the microstructure or surface morphology of the pastes. Finally, cell viability based on -(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) test and fluorescence staining experiments proved non-cytotoxicity and suitability of the studied carbon pastes as electrode material for measuring neural activity during surgeries (up to a certain time period).
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Neuroscience and Neural Engineering · Conducting polymers and applications · 3D Printing in Biomedical Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Barohn RJ, Jackson CE, Adams KK, Gronseth GS. An electrophysiologic comparison of stainless steel adhesive recording electrodes for nerve conduction studies. Muscle Nerve. 1995;18:1218–9.
2. Hubel DH. Tungsten microelectrode for recording from single units science. Science. 1957;125:549–50.10.1126/science.125.3247.549 ↗
3. Meyer RD, Cogan SF, Nguyen TH, Rauh DR. Electrodeposited iridium oxide for neural stimulation and recording electrodes. IEEE Trans Neural Systems Rehab Eng. 2001;9:2–11.10.1109/7333.918271 ↗
4. Ward MP, Rajdev P, Ellison C, Irazoqui PP. Toward a comparison of microelectrodes for acute and chronic recordings. Brain Res. 2009;1282:183–20.10.1016/j.brainres.2009.05.052 ↗
5. Pour Aryan N, Kaim H, Rothermel A, Stimulation and recording electrodes for neural prostheses. Springer briefs in electrical and computer engineering, Vol. 78, Springer, 2015, ISBN: 978-3-319-10051-7 (Print) 978-3-319-10052-4 (Online).10.1007/978-3-319-10052-4 ↗
6. Jorfi M, Skousen JL, Weder C, Capadona JR. Progress towards biocompatible intracortical microelectrodes for neural interfacing applications. J Neural Eng. 2015;12:011001.10.1088/1741-2560/12/1/011001 ↗
7. Harris AR, Morgan SJ, Chen J, Kapsa RM, Wallace GG, Paolini AG. Conducting polymer coated neural recording electrodes. J Neural Eng. 2013;10:016004.10.1088/1741-2560/10/1/016004 ↗
8. Varga M, Luniak M, Wolter KJ, Technology for bipolar polycarbonate electrodes applied for intraoperative neuromonitoring, Proc. 15th Electronics Packaging Technology Conference, December 11–13, 2013, Singapore, p. 103–7.10.1109/EPTC.2013.6745693 ↗
9. MacDonald RA, Laurenzi BF, Viswanathan G, Ajayan PM, Stegemann JP. Collagen-carbon nanotube composite materials as scaffolds in tissue engineering. J Biomed Mater Res A. 2005;74:489–96.10.1002/jbm.a.30386 ↗
10. Stout DA, Basu B, Webster TJ. Poly(lactic–co-glycolic acid): carbon nanofiber composites for myocardial tissue engineering applications. Acta Biomater. 2011;7:3101–12.10.1016/j.actbio.2011.04.028 ↗
11. Aragona J, Parsons JR, Alexander H, Weiss AB. Soft tissue attachment of a filamentous carbon-absorbable polymer tendon and ligament replacement. Clin Orthop Relat Res. 1981;160:268–78.10.1097/00003086-198110000-00039 ↗
12. Sales FC, Iost RM, Martins MV, Almeida MC, Crespilho FN. An intravenous implantable glucose/dioxygen biofuel cell with modified flexible carbon fiber electrodes. Lab Chip. 2013;13:468–74.10.1039/C2LC41007A ↗
13. Takashi D, Kozai Y, Langhals NB, Patel PR, Deng X, Zhang H, Smith KL, Lahann J, Kotov NA, Kipke DR. Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces. Nat Mater. 2012;11:1065–73.10.1038/nmat3468 ↗
14. Ozdemir KG, Yilmaz H, Yilmaz S. In vitro evaluation of cytotoxicity of soft lining materials on L929 cells by MTT assay. J Biomed Mater Res B Appl Biomater. 2009;90:82–6.10.1002/jbm.b.31256 ↗
15. Atay A, Bozok Cetintas V, Cal E, Kosova B, Kesercioglu A, Guneri P. Cytotoxicity of hard and soft denture lining materials. Dent Mater J. 2012;31:1082–6.10.4012/dmj.2012-209 ↗
16. Lugscheider E, Knepper M, Heimberg M. Cytotoxicity investigations of plasma-sprayed calcium phosphate coatings. J Mater Sci: Mater Med. 1994;5:371–5.
17. Herrera Morales JM, Souriau JC, Ratel D, Berger F, Simon G. Biophysicochemical evaluation of passivation layers for the packaging of silicon microsystems in medical devices, Proceedings of the 2014 Electronic Components & Technology Conference (ECTC), Orlando, FL, 2014, pp. 478–83.10.1109/ECTC.2014.6897327 ↗
18. Waiwijit U, Kandhavivorn W, Oonkhanond B, Lomas T, Phokaratkul D, Wisitsoraat A, Tuantranont A. Cytotoxicity assessment of MDA-MB-231 breast cancer cells on screen-printed graphene-carbon paste substrate. Colloids Surf B Biointerfaces. 2014;113:190–7.10.1016/j.colsurfb.2013.09.008 ↗
19. Zhao S, Liu X, Xu Z, Ren H, Deng B, Tang M, Lu L, Fu X, Peng H, Liu Z, Duan X. Graphene encapsulated copper microwires as highly MRI compatible neural electrodes. Nano Lett. 2016. doi: 10.1021/acs.nanolett.6b03829 .10.1021/acs.nanolett.6b03829 ↗
20. Popovic MR, Curt A, Keller T, Dietz V. Functional electrical stimulation for grasping and walking: indications and limitations. Spinal Cord. 2001;39:403–12.10.1038/sj.sc.3101191 ↗
21. Hamza MA, White PF, Craig WF, Ghoname ES, Ahmed HE, Proctor TJ, Noe CE, Vakharia AS, Gajraj N. Percutaneous electrical nerve stimulation: a novel analgesic therapy for diabetic neuropathic pain. Diabetes Care. 2000;23:365–70.10.2337/diacare.23.3.365 ↗
22. Vonck K, de Herdt V, Sprengers M, Ben-Menachem E. Neurostimulation for epilepsy. In: Stefan H, Theodore WH, editors. Handbook of clinical neurology. Amsterdam: Elsevier B.V; 2012. p. 955–70.
23. Hara Y. Neurohabilitation with new functional electrical stimulation for hemiparetic upper extremity in stroke patients. J Nippon Med Sch. 2008;75:4–14.10.1272/jnms.75.4 ↗
24. Henry CL, Streeter I, Wildgoose GG, Lawrence NS, Jiang L, Jones TGJ, Compton RG. Derivatised carbon powder electrodes: reagentless pH sensors, Talanta, Elsevier, 2004; 63(4):1039–51, doi: 10.1016/j.talanta.2004.01.017 .10.1016/j.talanta.2004.01.017 ↗
25. Lee S, Jo G, Kang SJ, Wang G, Choe M, Park W, Kim DY, Kahng YH, Lee T. Enhanced charge injection in pentacene field-effect transistors with graphene electrodes. Adv Mater. 2011;23:100–5.10.1002/adma.201003165 ↗
26. Wang G, Kim Y, Choe M, Kim TW, Lee T. A new approach for molecular electronic junctions with a multilayer graphene electrode. Adv Mater. 2011;23:755–60.10.1002/adma.201003178 ↗
27. Wang X, Zhi L, Muellen K. Transparent, conductive graphene electrodes for dye-sensitized solar cells. Nano Lett. 2008;8:323–7.10.1021/nl072838r ↗
28. Jo G, Choe M, Cho CY, Kim JH, Park W, Lee S, Hong WK, Kim TW, Park SJ, Hong BH, Kahng YH, Lee T. Large-scale patterned multi-layer graphene films as transparent conducting electrodes for GaN light-emitting diodes. Nanotechnology 2010;21(17):175201, doi: 10.1088/0957-4484/21/17/175201 .10.1088/0957-4484/21/17/175201 ↗
29. Svancara I, Kalcher K, Walcarius A, Vitras K, Electroanalysis with carbon paste electrodes, Analytical chemistry series, Boca Raton: CRC Press Taylor and Francis; 2012.10.1201/b11478 ↗
30. Kirgöz ÜA, Odaci D, Timur S, Merkoc A, Alegret S, Besün N, Telefoncu A. A biosensor based on graphite/epoxy composite electrode for aspartame and ethanol detection. Anal Chim Acta. 2006;570:165–9.10.1016/j.aca.2006.04.010 ↗
31. Mailley P, Cummings EA, Mailley SC, Eggins BR, McAdams E, Cosnier S. Composite carbon paste biosensor for phenolic derivatives based on in situ electrogenerated polypyrrole binder. Anal Chem. 2003;75:5422–8.10.1021/ac034177y ↗
32. Wang J, Kirgöz UA, Mo J, Lu J, Kawde AN, Muck A. Glassy carbon paste electrodes. Electrochem Commun. 2001;3:203–8.10.1016/S1388-2481(01)00142-4 ↗
33. Rice ME, Galus Z, Adams RN. Graphite paste electrodes: effects of paste composition and surface states on electron-transfer rates. J Electroanal Chem. 1983;143:89–102.10.1016/S0022-0728(83)80256-3 ↗
34. Rodriguez MC, Rivas GA. Glassy carbon paste electrodes modified with polyphenol oxidase: analytical applications. Anal Chim Acta. 2002;459:43–51.10.1016/S0003-2670(02)00088-0 ↗
35. Önnerfjord P, Emnéus J, Varga GYM, Gorton L. Tyrosinase graphite-epoxy based composite electrodes for detection of phenols. Biosens Bioelectron. 1995;10:607–19.10.1016/0956-5663(95)96937-T ↗
36. Lackwerke Peters GmbH + Co, Technical datasheet for SD 2843 HAL. 2014, http://pcb.gatema.cz/files/ckeditor/ke_stazeni/technick%C3%A9_listy/TL_-_SD_2843_HAL.pdf .
37. DuPont, Technical datasheet for DuPont 7102, 2014, http://www.dupont.com/content/dam/dupont/products-and-services/electronic-and-electrical-materials/documents/prodlib/7102.pdf .
38. DuPont, Technical datasheet for DuPont 8144, 2014, http://www.dupont.com/content/dam/dupont/products-and-services/electronic-and-electrical-materials/documents/prodlib/8144.pdf .
39. Dalby MJ, Gadegaard N, Tare R, Andar A, Riehle MO, Herzyk P, Wilkinson CDW, Oreffo ROC. The control of human mesenchymal cell differentiation using nanoscale symmetry and disorder. Nat Mater. 2007;6:997–1003.10.1038/nmat2013 ↗
40. Arnold M, Schwieder M, Blummel J, Cavalcanti-Adam EA, Lopez-Garcia M, Kessler H, Geiger B, Spatz JP. Cell interactions with hierarchically structured nano-patterned adhesive surfaces. Soft Matter. 2009;5:72–7.10.1039/B815634D ↗
41. Stevens MM, George JH. Exploring and engineering the cell surface interface. Science. 2005;310:1135–8.10.1126/science.1106587 ↗
42. Lehnert D, Wehrle-Haller B, David C, Weiland U, Ballestrem C, Imhof BA, Bastmeyer M. Cell behaviour on micropatterned substrata: limits of extracellular matrix geometry for spreading and adhesion. J Cell Sci. 2004;117:41–52.10.1242/jcs.00836 ↗
43. Chou SY, Cheng CM, Leduc PR. Composite polymer systems with control of local substrate elasticity and their effect on cytoskeletal and morphological characteristics of adherent cells. Biomaterials. 2009;18:3136–42.10.1016/j.biomaterials.2009.02.037 ↗
44. Lord MS, Foss M, Besenbacher F. Influence of nanoscale surface topography on protein adsorption and cellular response. Nano Today. 2010;5:66–78.10.1016/j.nantod.2010.01.001 ↗
45. Shadpour H, Allbritton NL. In-situ roughening of polymeric microstructures. ACS Appl Mater Interfaces. 2010;2:1086–93.10.1021/am900860s ↗
46. Turner AMP, Dowell N, Turner SWP, Kam L, Isaacson M, Turner JN, Craighead HG, Shain W. Attachment of astroglial cells to microfabricated pillar arrays of different geometries. J Biomed Mater Res. 2000;51:430–41.10.1002/1097-4636(20000905)51:3<430::AID-JBM18>3.0.CO;2-C ↗
47. Lu J, Rao MP, MacDonald NC, Khang D, Webster TJ. Improved endothelial cell adhesion and proliferation on patterned titanium surfaces with rationally designed, micrometer to nanometer features. Acta Biomater. 2008;4:192–201.10.1016/j.actbio.2007.07.008 ↗
48. Kalbacova M, Broz A, Kong J, Kalbac M. Graphene substrates promote adherence of human osteoblasts and mesenchymal stromal cells. Carbon. 2010;48:4323–9.10.1016/j.carbon.2010.07.045 ↗