journal article·2002-05

Fretting wear study of surface modified Ni–Ti shape memory alloy

L. Tan, W. C. Crone, K. Sridharan

Publisher page

Abstract

A combination of shape memory characteristics, pseudoelasticity, and good damping properties make near-equiatomic nickel-titanium (Ni-Ti) alloy a desirable candidate material for certain biomedical device applications. The alloy has moderately good wear resistance, however, further improvements in this regard would be beneficial from the perspective of reducing wear debris generation, improving biocompatibility, and preventing failure during service. Fretting wear tests of Ni-Ti in both austenitic and martensitic microstructural conditions were performed with the goal of simulating wear which medical devices such as stents may experience during surgical implantation or service. The tests were performed using a stainless steel stylus counter-wearing surface under dry conditions and also with artificial plasma containing 80 g/L albumen protein as lubricant. Additionally, the research explores the feasibility of surface modification by sequential ion implantation with argon and oxygen to enhance the wear characteristics of the Ni-Ti alloy. Each of these implantations was performed to a dose of 3 x 10(17) atom/cm(2) and an energy of 50 kV, using the plasma source ion implantation process. Improvements in wear resistance were observed for the austenitic samples implanted with argon and oxygen. Ion implantation with argon also reduced the surface Ni content with respect to Ti due to differential sputtering rates of the two elements, an effect that points toward improved biocompatibility.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Shape Memory Alloy Transformations · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. T. W. Duerig, A. R. Pelton and D. Stockel, Med. Device Diagn. Ind. March (1997).
2. D. Stoeckel, Minim. Invasiv. Ther. 9(2) (2000) 81.10.3109/13645700009063054 ↗
3. D. Y. Li and R. Liu, Wear 225–229 (1999) 777.10.1016/S0043-1648(98)00388-3 ↗
4. D. Y. Li, ibid. 221 (1998) 116.10.1016/S0043-1648(98)00269-5 ↗
5. Y. N. Liang, S. Z. Li, Y. B. Jin, W. Jin and S. Li, ibid. 198 (1996) 236.10.1016/0043-1648(96)06989-X ↗
6. P. Clayton, ibid. 162 (1993) 202.10.1016/0043-1648(93)90502-D ↗
7. J. Ryhanen, Minim. Invasiv. Ther. 9(2) (2000) 99.10.3109/13645700009063056 ↗
8. J. Ryhanen, “Biocompatibility Evaluation of Nickel-Titanium Shape Memory Metal Alloy,” Ph.D. Thesis, Oulu University, Finland (1999).
9. C. L. Dunlap, S. K. Vincent and B. F. Barker, J. Am. Dent. Assoc. 118 (1989) 449.10.14219/jada.archive.1989.0174 ↗
10. E. M. H. Al-Waheidi, Quintessence International 26(6) (1995) 385.
11. R. Vandenkerckhove, E. Temmerman and R. Verbeeck, Mater. Sci. Forum, 289–292 (1998) 1289.10.4028/www.scientific.net/MSF.289-292.1289 ↗
12. M. Berger-Gorbet, B. Broxup, C. Rivard and L. H. Yahia, J. Biomed. Mater. Res. 32 (1996) 243.10.1002/(SICI)1097-4636(199610)32:2<243::AID-JBM14>3.0.CO;2-K ↗
13. D. J. Chwirut, H. S. Oktay and T. Ryan, in “SMST-97: Proceedings of the Second International Conference on Shape Memory and Pseudoelastic Technologies”, edited by A. Pelton (Pacific Grove, California, USA, 1997) p. 369.
14. S. Trigwell and G. Selvaduray, in “SMST-97: Proceedings of the Second International Conference on Shape Memory ad Pseudoelastic Technologies”, edited by A. Pelton (Pacific Grove, California, USA, 1997) p. 383.
15. C.-M. Dhan, S. Trigwell and T. W. Duerig, Surf. Interface. Anal. 15 (1990) 349.10.1002/sia.740150602 ↗
16. M. R. Wolff, Professor of Medicine and Director of Interventional Cardiology, University Hospital and Clinics, University of Wisconsin, Madison, USA, private communication, June 16, 2000.
17. P. Moine, O. Popoola and J. P. Villain, Scripta Metallurgica 20 (1986) 305.10.1016/0036-9748(86)90148-1 ↗
18. P. Moine, O. Popoola, J. P. Villain, N. Junqua, S. Pimbert, J. Delafond and J. Grilhe, Surf. Coat. Tech. 33 (1987) 479.10.1016/0257-8972(87)90212-X ↗
19. O. Popoola, M. F. Denanot, P. Moine, J. P. Villain, M. Cahoreau and J. Caisso, Acta Metall. 37(3) (1989) 867.10.1016/0001-6160(89)90013-8 ↗
20. J. R. Conrad, Mater. Sci. Engr. A, 116 (1989) 197.10.1016/0921-5093(89)90146-9 ↗
21. A. Anders (ed.), “Handbook of Plasma Immersion Ion Implantation and Deposition” (John Wiley & Sons, New York, 2000).
22. W. C. Crone and K. Sridharan, in “SMST-Proceedings of the International Conference on Shape Memory and Pseudoelastic Technologies” (2000).
23. G. F. Vander Voort and G. M. Lucas, Adv. Mater. Process. 154(3) (1998) 21.
24. P. W. Sandstrom, K. Sridharan and J. R. Conrad, Wear 166 (1993) 163.10.1016/0043-1648(93)90258-N ↗
25. French Association of Standardization (AFNOR), Standard NF S 91–141, September (1990) ISSN 0336-3931.
26. N. Matsunami, Y. Yamamura, Y. Itikawa, N. Itoh, Y. Kazumata, S. Miyagawa, K. Morita and R. Shimizu, in “Energy Dependence of Sputtering Yields of Monoatomic Solids” (Institute of Plasma Physics, Nagoya University, Chikusa-ku, Nagoya 464, Japan, June 1980).
27. A. D. Sarkar, in “Wear of Materials” vol. 18 (Pergamon, Oxford, 1976).
28. J. Halling (ed.), “Principals of Tribology” (Macmillan, London, 1975).
29. A. R. Pelton, J. Dicello and S. Miyazaki, Minim. Invasiv. Ther. 9(2) (2000) 107.10.3109/13645700009063057 ↗