Abstract
In revision hip replacement surgery cortical strut grafts made of allograft bone are used to augment femoral bone stock and to fix periprosthetic femoral fractures. These struts are made from femoral bone as hemi-cylinders and are fixed to host bone with cerclage wires. We developed an artificial bone substitute for such strut grafts in order to overcome availability restrictions and potential infectious hazards with allograft bone. The partially biodegradable implant consists of a functionally-graded combination of titanium, polylactide, hydroxyapatite, and calcium carbonate. It is made by manual dip-coating of the metal (after chemical surface treatment) into solutions of polylactide with suspended calcium salts. In this way the titanium core is surrounded by an inner layer of slowly biodegradable poly(L-lactide) with calcium carbonate. The part of the implant that is in contact with the bone consists of rapidly biodegradable poly(D,L-lactide), hydroxyapatite and calcium carbonate. This method leads to an implant which is easily adaptable before the implantation to the geometry of the patient's bone when moderately heated (70 degrees C), but has a sufficient mechanical strength to serve as support under physiologic temperatures. The implant is mechanically stable, biocompatible, partially biodegradable, and provides a scaffold for growing bone.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · biodegradable polymer synthesis and properties · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. W. C. HEAD and T. I. MALININ, Clin. Orthop. Relat. R. 371 (2000) 10810.1097/00003086-200002000-00012 ↗
2. V. M. GOLDBERG, Clin. Orthop. Relat. R. 381 (2000) 6810.1097/00003086-200012000-00008 ↗
3. S. C. GAMRADT and J. R. LIEBERMAN, Clin. Orthop. Relat. R. 417 (2003) 18310.1097/01.blo.0000096814.78689.77 ↗
4. H. P. CHANDLER and R. G. TIGGES, J. Bone Joint Surg. [Am] 79-A (1997) 142210.2106/00004623-199709000-00020 ↗
5. G. A. HELM, H. DAYOUB and J. A. JANE Jr., Neurosurg. Focus 10(4) (2001) Article 4, 110.3171/foc.2001.10.4.5 ↗
6. L. VASTEL, A. MEUNIER, H. SINEY, L. SEDEL and J.-P. COURPIED, Biomaterials 25 (2004) 210510.1016/j.biomaterials.2003.08.067 ↗
7. J. M. RUEGER, Orthopäde 27 (1998) 72
8. A. S. GREENWALD, S. D. BODEN, V. M. GOLDBERG, Y. KHAN, C. T. LAURENCIN and R. N. ROSIER, J. Bone Joint Surgery 83A (2001) 9810.2106/00004623-200100022-00007 ↗
9. D. TADIC and M. EPPLE, Biomaterials 25 (2004) 98710.1016/S0142-9612(03)00621-5 ↗
10. T. DONATH, F. BECKMANN, R. G. J. C. HEIJKANTS, O. BRUNKE and A. SCHREYER, SPIE Proc. 5535 (2004) 77510.1117/12.559025 ↗
11. K. PARTALE, P. KLEIN, H. SCHELL, G. SCHMIDMAIER, B. WILDEMANN, H. BAIL, R. SCHILLER, H. BRAGULLA and G. N. DUDA, J. Biomed. Mater. Res. Part B: Appl. Biomater. 74B, (2005) 60810.1002/jbm.b.30254 ↗
12. A. A. IGNATIUS and L. E. CLAES, Biomaterials 17, (1996) 83110.1016/0142-9612(96)81421-9 ↗
13. K. A. ATHANASIOU, G. G. NIEDERAUER and C. M. AGRAWAL, Biomaterials 17, (1996) 9310.1016/0142-9612(96)85754-1 ↗
14. P. MAINIL-VARLET, B. RAHN and S. GOGOLEWSKI, Biomaterials 18, (1997) 25710.1016/S0142-9612(96)00126-3 ↗
15. C. SCHILLER and M. EPPLE, Biomaterials 24, (2003) 203710.1016/S0142-9612(02)00634-8 ↗
16. A. GOPFERICH, Biomaterials 18, (1997) 39710.1016/S0142-9612(96)00151-2 ↗
17. E. A. R. DUEK, C. A. C. ZAVAGLIA and W. D. BELANGERO, Polymer 40, (1999) 646510.1016/S0032-3861(98)00846-5 ↗
18. L. LU, S. J. PETER, M. D. LYMAN, H. L. LAI, S. M. LEITE, J. A. TAMADA, J. P. VACANTI, R. LANGER and A. G. MIKOS, Biomaterials 21, (2000) 159510.1016/S0142-9612(00)00048-X ↗
19. F. von BURKERSRODA, L. SCHEDL and A. GÖPFERICH, Biomaterials 23, (2002) 422110.1016/S0142-9612(02)00170-9 ↗
20. S.V. DOROZHKIN and M. EPPLE, Angew. Chem. Int. Ed. 41, (2002) 313010.1002/1521-3773(20020902)41:17<3130::AID-ANIE3130>3.0.CO;2-1 ↗
21. S. WEINER and H. D. WAGNER, Annu. Rev. Mater. Sci. 28, (1998) 27110.1146/annurev.matsci.28.1.271 ↗
22. A. SLÓSARCZYK, J. SZYMURA-OLEKSIAK and B. MYCEK, Biomaterials 21, (2000) 121510.1016/S0142-9612(99)00269-0 ↗
23. S. JOSSE, C. FAUCHEUX, A. SOUEIDAN, G. GRIMANDI, D. MASSIOT, B. ALONSO, P. JANVIER, S. LAÏB, O. GAUTHIER, G. DACULSI, J. GUICHEUX, B. BUJOLI and J. -M. BOULER, Adv. Mater. 16, (2004) 142310.1002/adma.200306340 ↗
24. S. A. T. van der MEER, J. R. de WIJN and J. G. C. WOLKE, J. Mater. Sci. Mater. Med. 7, (1996) 35910.1007/BF00154549 ↗
25. C. M. AGRAWAL and K. A. ATHANASIOU, J. Biomed. Mater. Res. 38, (1997) 10510.1002/(SICI)1097-4636(199722)38:2<105::AID-JBM4>3.0.CO;2-U ↗
26. W. LINHART, F. PETERS, W. LEHMANN, A. F. SCHILLING, K. SCHWARZ, M. AMLING, J. M. RUEGER and M. EPPLE, J. Biomed. Mater. Res. 54, (2001) 16210.1002/1097-4636(200102)54:2<162::AID-JBM2>3.0.CO;2-3 ↗
27. D. D. HILE, S. A. DOHERTY, D. J. TRANTOLO, J. Biomed. Mater. Res. Part B: Appl. Biomater. 71B, (2004) 20110.1002/jbm.b.30091 ↗
28. C. SCHILLER, C. RASCHE, M. WEHMÖLLER, F. BECKMANN, H. EUFINGER, M. EPPLE and S. WEIHE, Biomaterials 25, (2004) 123910.1016/j.biomaterials.2003.08.047 ↗