Effect of drying conditions during synthesis on the properties of hydroxyapatite powders
Source abstract
Abstract
The effect of the drying conditions during the hydroxyapatite (HAp) powder synthesis on the size and microstructure was studied. The starting materials were agitated in water, dried at 60-150 degrees C, and heat-treated at 720 degrees C. The heat-treated HAp powders were crystalline, and their particle sizes decreased with an increase in the drying time, but were independent of the drying temperature. For a 3 day drying period, it was 1.61 microm, and 0.55 microm for 21 days. The surface zeta potential of the HAp powder with a long drying period was more negatively charged than that from the short drying period. The average primary particle sizes of the HAp powders seem to be almost equivalent, and so the drying period may be related to the dispersibility of the primary particles, and may lead to a small HAp particle size.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Additive Manufacturing and 3D Printing Technologies · Engineering Technology and Methodologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. K. DE GROOT, Biomaterials 1 (1980) 4710.1016/0142-9612(80)90059-9 ↗
2. J. D. DE BRUIJIN, Y. P. BOVELL and C. A. VAN BLITTERSWIJK, Biomaterials 15 (1994) 54310.1016/0142-9612(94)90021-3 ↗
3. Y. YOKOGAWA, J. Chem. Ind. 5 (2001) 57
4. M. WANG, R. JOSEPH and W. BONFIELD, Biomaterials 19 (1998) 235710.1016/S0142-9612(98)00154-9 ↗
5. I. R. GIBSON, S. KE, S. M. BEST and W. BONFIELD, J. Mater. Sci. Mater. Med. 12 (2001) 16310.1023/A:1008930313194 ↗
6. F. LELIEVER, D. BERNACHE-ASSOLLANT and T. CHARTIER, J. Mater. Med. 7 (1996) 48910.1007/BF00705430 ↗
7. W. R. RAO and R. F. BOEHM, J. Dent. Res. 53 (1974) 135110.1177/00220345740530061001 ↗
8. P. E. WANG and T. K. CHAKI, J. Mater. Sci. 4 (1993) 150
9. A. ROYER, J. VIGUIE, C. M. HEUGHEBAERT and J. C. HEUGHEBAERT, J. Mater. Sci. Mater. Med. 4 (1993) 7610.1007/BF00122982 ↗
10. S. M. BEST and W. BONFIELD, J. Mater. Sci. Mater. Med. 5 (1994) 51610.1007/BF00124883 ↗
11. S. PUIJINDANATER, S. M. BEST and W. BONFIELD, Br. Ceram Trans. 93 (1994) 96
12. M. G. S. MURRAY, J. WANG, C. B. PANTON and P. M. MARQUIS, J. Mater. Sci. 30 (1995) 306110.1007/BF01209218 ↗
13. P. VAN LANDUYT, F. LI, J. P. KEUSTERMANS, J. M. STREYDIO, F. DELANNAY and E. MUNTING, J. Mater. Sci. Mater. Med. 6 (1995) 810.1007/BF00121239 ↗
14. A. J. RUYS, M. WEI, C. C. SORRELL, M. R. DICKSON, A. BRANDWOOD and B. K. MITHORPE, Biomaterials 16 (1995) 40910.1016/0142-9612(95)98859-C ↗
15. D.-M. LIU, Ceram. Inter. 24 (1998) 44110.1016/S0272-8842(97)00033-3 ↗
16. T. TORIYAMA, Y. KAWAMOTO, T. SUZUKI, Y. YOKOGAWA and S. KAWAMURA, Rep. Gov. Ind. Res. Inst. Nagoya 39 (1990) 217
17. A. OSAKA, Y. MIURA, K. TAKEUCHI, M. ASADA and K. TAKAHASHI, J. Mater. Med. 2 (1991) 5110.1007/BF00701687 ↗
18. I. R. GIBSON, S. M. BEST and W. BONFIELD, J. Biomed. Mater. Res. 44 (1999) 42210.1002/(SICI)1097-4636(19990315)44:4<422::AID-JBM8>3.0.CO;2-# ↗
19. M.-F. HSIEH, L.-H. PERNG, T.-S. CHIN and H.-G. PENG, Biomaterials 22 (2001) 260110.1016/S0142-9612(00)00448-8 ↗