journal article·2008-03

The influence of residual stress on the shear strength between the bone and plasma-sprayed hydroxyapatite coating

Yung-Chin Yang, Chyun-Yu Yang

Publisher page

Abstract

Plasma-sprayed HA coating (HAC) 50 and 200 microm thick on Ti6Al4V cylinders was transcortically implanted in the femora of canines. Push-out testing of implant-bone interfaces showed that the HAC coating exhibited higher shear strength at 50 microm coating than 200 microm one. The plasma-sprayed HACs were exhibited compressive residual stresses and the thicker HAC exhibited higher residual stress than that of the thinner HAC. Due to the structure for 50 and 200 microm implants were the same, meaning similar cohesive strength of the lamellar splats. And, there was no difference in the physiological environment; hence the difference of the shear strength for the 50 and 200 microm-HAC implants could best be attributed to the compressive residual stress existed in the HA coating.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. S. PAOLO, L. MATTEO and B. LUCA, Thin Solid Films 278 (1996) 9610.1016/0040-6090(95)08163-1 ↗
2. S. KURODA and T. W. CLYNE, Thin solid films. 200 (1991) 4910.1016/0040-6090(91)90029-W ↗
3. S. TAKEUCHI, M. ITO and K. TAKEDA, Surf. Coat. Technol. 43/44 (1990) 42610.1016/0257-8972(90)90094-S ↗
4. A. G. EVANS, G. B. CRUMLEY and R. F. DEMARAY, Oxid. Met. 20 (1983) 19610.1007/BF00656841 ↗
5. R. MEVREL, Mater. Sci. Technol. 3 (1987) 53110.1080/02670836.1987.11782264 ↗
6. Y. C. YANG and E. CHANG, Biomaterials. 22 (2001) 182710.1016/S0142-9612(00)00364-1 ↗
7. Y. C. YANG, E. CHANG and S. Y. LEE, J. Biomed. Mater. Res. 67A (2003) 88610.1002/jbm.a.10145 ↗
8. V. SERGO, O. SBAIZERO and R. D. CLARKE, Biomaterials. 18 (1997) 47710.1016/S0142-9612(96)00147-0 ↗
9. R. G. GEESINK, K. de GROOT and C. P. KLEIN, Clin. Orthop. 225 (1987) 14710.1097/00003086-198712000-00014 ↗
10. S. D. COOK, K. A. THOMAS, J. F. KAY and M. JARCHO, Clin. Orthop. 232 (1988) 225
11. K. SOBALLE, E. S. HANSEN, H. B. RASMUSSEN, C. M. PEDERSEN and C. BUNGER, Acta. Orthop. Scand. 61 (1990) 29910.3109/17453679008993521 ↗
12. Y. C. YANG, E. CHANG, B. H. HWANG and S. Y. LEE, Biomaterials. 21 (2000) 132710.1016/S0142-9612(99)00272-0 ↗
13. T. KOKUBO, In CRC handbook of bioactive ceramics vol. 1. T. Yamamuro, L. L. Hench, J. Wilson (eds). (CRC Press, Florida 1990) p. 41
14. ASTM E855-90. Standard test methods for bend testing of metallic flat materials for spring applications involving static loading. American Society for Testing Materials (1990)
15. ASTM C 633-79. Standard test method for adhesion or cohesive strength of flame-sprayed coatings
16. K. de GROOT, C. P. A. T. KLEIN, J. G. C. WOLKE and J. M. A. de BLIECK-HOGER-VORST, in CRC Handbook of Bioactive Ceramics vol. II. edited by T. Yamamuro, L. L. Hench, J. Wilson (CRC Press Inc., Boca Raton, Florida, 1990) pp. 133–142
17. K. A. GROSS and C. C. BERNDT, J. Mater. Sci. Mater. Med. 5 (1994) 21910.1007/BF00121092 ↗
18. R. L. COBLE and W. D. KINGERY, J. Am. Ceram. Soc. 39[11] (1956) 381
19. H. RAO, W. A. THOMPSON, J. L. KATZ and R. A. HARPER, J. Dent. Res. 55 (1976) 70810.1177/00220345760550043501 ↗
20. G. de WITH, H. J. A. VANDIJK, N. HATTU and K. PRIJS, J. Mater. Sci. 16 (1981) 159210.1007/BF02396876 ↗
21. M. AKAO, H. AOKI and K. KATO, J. Mater. Sci. 16 (1981) 80910.1007/BF02402799 ↗
22. H. E. EATON and R. C. NOVAK, Surf. Coat. Technol. 27 (1986) 25710.1016/0257-8972(86)90105-2 ↗
23. C. J. LI, A. OHMORI and R. MCPHERSON, J. Mater. Sci. 32 (1997) 99710.1023/A:1018574221589 ↗
24. K. S. SHI, Z. Y. QIAN and M. S. ZHUANG, J. Am. Ceram. Soc. 71 (1998) 92410.1111/j.1151-2916.1988.tb07559.x ↗
25. Y. C. TSUI, C. DOYLE and T. W. CLYNE, Biomaterials 19 (1998) 201510.1016/S0142-9612(98)00103-3 ↗
26. Y. HAN, K. W. XU and J. LU, J. Biomed. Mater. Res. 26 (2001) 59610.1002/1097-4636(20010615)55:4<596::AID-JBM1053>3.0.CO;2-Y ↗
27. B. C. WANG, E. CHANG, C. Y. YANG, D. TU and C. H. TSAI, Surf. Coat. Technol. 58 (1993) 10710.1016/0257-8972(93)90181-M ↗
28. W. THOMAS, C. T. RUDOLPH, Z. RICHARD and T. JAMES, J. Bone. Joint Surg. (American volume) 73A (1991) 1452
29. W.P. HU, K. A. LAI, C. H. LIN, C. Y. YANG and G. L. CHANG, in Bioengineering, Proceedings of the Northeast Conference IEEE 28th Annual Northeast Bioengineering Conference Apr 20–21 2002
30. J. M. SPIVAK, J. L. RICCI, N. C. BLUMENTHAL and H. ALEXANDER, J. Biomed. Mater. Res. 24 (1990) 112110.1002/jbm.820240902 ↗
31. K. HAYASHI, T. MASHIMA and K. UENOYAMA, Biomaterials. 20 (1999) 11110.1016/S0142-9612(98)00011-8 ↗
32. T. INADOME, K. HAYASHI, Y. NAKASHIMA, H. TSUMURA and Y. SUGIOKA, J. Biomed. Mater. Res. 29 (1995) 1910.1002/jbm.820290104 ↗
33. T. OTANI, L. A. WHITESIDE and S. E. WHITE, J. Biomed. Mater. Res. 27 (1993) 57510.1002/jbm.820270504 ↗