journal article·2011-04

Povidone–iodine as a corrosion inhibitor towards a low modulus beta Ti-45Nb implant alloy in a simulated body fluid

S. M. Bhola, R. Bhola, B. Mishra, D. L. Olson

Publisher page

Abstract

Povidone-iodine and various bactericidal agents used in dental procedures may affect the corrosion response of an implant/prosthesis in the oral environment. The effect of various concentrations of povidone-iodine (PI) on the corrosion behavior of a low modulus beta titanium alloy, Ti-45Nb, has been investigated in normal saline solution. The open circuit potential, electrochemical impedance spectroscopy and potentiodynamic polarization measurements have been used to assess the electrochemical response of the alloy surface on PI addition so as to effectively predict the prosthetic treatment outcome. As the concentration of PI is increased, the corrosion rate decreases, suggested by decreased R(p) values. Povidone-iodine acts as an anodic inhibitor by adsorbing on the anodic sites of the alloy. Addition of PI to a simulated body fluid such as normal saline leads to a decrease in corrosion rate of Ti-45Nb alloy.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (21)

Show source-provided references
1. Demir A, Malkoc S, Sengun A, Koyuturk AE, Sener Y. Effects of chlorohexidine and povidone–iodine mouth rinses on the bond strength of an orthodontic composite. Angle Orthod. 2005;75(3):392–6.
2. Barabas EZ. Vinylamines encyclopedia of polymer science and engineering, vol. 17. 2nd ed. New York: Wiley; 1989. p. 219.
3. Brittain HG. Analytical profiles of drug substances and excipients, vol. 22. San Diego: Academic Press; 1998. p. 25.
4. Fuoss RM, Strauss VP. Viscosity of mixtures of polyelectrolytes and simple electrolytes. Ann N Y Acad Sci. 1949;51:836.10.1111/j.1749-6632.1949.tb27309.x ↗
5. LaRocca R, LaRocca M-AK, Ansell JM. Microbiology of povidone–iodine, In: Proc. Intl. Symp. On Povidone, Digenis GA, Ansell J, editors. University of Kentucky College of Pharmacy 1983; 101.
6. Broussoulaux C. A New Antiseptic: Polyvinylpyrrolidone-Iodine, Dissertation submitted in partial fulfillment for the Doctorate of Medicine, University of Paris (France) 1965 (submitted).
7. Cournoyer RF, Siggia S. Interaction of poly(vinyl-pyrrolidone) and iodine. J Polym Sci. 1974;12:603.
8. Daniels WE, Chiddix ME, Glickman SA. Lactam complexes of Br–HBr. J Org Chem. 1963;28:573.10.1021/jo01037a507 ↗
9. Ferguson AW, Scott JA, McGavigan J, Elton RA, McLean J, Schmidt U, Kelkar R, Dhillon B. Comparison of 5% povidone–iodine solution against 0.1% povidone–iodine solution in preoperative cataract surgery antisepsis: a prospective randomized double blind study. Br J Ophthalmol. 2003;87:163–7.10.1136/bjo.87.2.163 ↗
10. Bhola R, Bhola SM, Mishra B, Olson DL. Effect of povidone–iodine addition on the corrosion behavior of cp-Ti in normal saline. J Mater Sci Mater Med. 2010. doi: 10.1007/s10856-010-4001-0 .10.1007/s10856-010-4001-0 ↗
11. Chu PK, Chen JY, Wnag LP, Huang N. Plasma-surface modification of biomaterials. Mater Sci Eng: R: Rep. 2002;36(5–6):143–206.10.1016/S0927-796X(02)00004-9 ↗
12. Eisenbarth E, Velten D, Muller M, Thull R, Breme J. Biocompatibility of β-stabilizing elements of titanium alloys. Biomaterials. 2004;25:5705–13.10.1016/j.biomaterials.2004.01.021 ↗
13. Hanawa T. Metal ion release from metal implants. Mater Sci Eng C. 2004;24:745–52.10.1016/j.msec.2004.08.018 ↗
14. Niinomi M. Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr. Biomaterials. 2003;24:2673–83.10.1016/S0142-9612(03)00069-3 ↗
15. ASTM Standard F-04.12.44, ASTM International, Conshohocken, PA, USA.
16. Hsu CH, Mansfeld F. Technical note: concerning the conversion of the constant phase element parameter (Y0) into a capacitance. Corrosion. 2001;57:747–8.10.5006/1.3280607 ↗
17. Chongdar S, Gunasekaran G, Kumar P. Corrosion inhibition of mild steel by aerobic biofilm. Electrochim Acta. 2005;50:4655–65.10.1016/j.electacta.2005.02.017 ↗
18. Umoren SA, Eduok UM, Oguzie EE. Corrosion inhibition of mild steel in 1 M H2SO4 by polyvinyl pyrrolidone and synergistic iodide additives. Portugaliae Electrochimica Acta. 2008;26(6):533–46.10.4152/pea.200806533 ↗
19. Umoren SA, Ebenso EE. Blends of polyvinyl pyrrolidone and polyacrylamide as corrosion inhibitors for aluminium in acidic medium. Indian J Chem Technol. 2008;15:355–63.
20. Öztan, MD, Akman AA, Zaimoglu L, Bilgic S. Corrosion rates of stainless steel files in different irrigating solutions. Int Endod J. 2002;35:655–9.10.1046/j.1365-2591.2002.00530.x ↗
21. Bhola SM, Bhola R, Mishra B, Olson DL. An electrochemical study on chlorhexidine gluconate addition to normal saline for oral implant applications. J Mater Sci: Mater Med (submitted).