journal article·2009-12Open access

Load sensing surgical instruments

C. Jacq, T. Maeder, P. Ryser

Abstract

Force and pressure sensing technology applied to smart surgical instruments as well as implants allow to give a direct feedback of loads to the surgeon lead to better reliability and success of surgical operations. A common technology used for sensors is low-cost piezoresistive thick-film technology. However, the standard thick-film firing conditions degrade the properties of medical alloys. In order to avoid this problem, the solution is to decrease the firing temperature of thick films. This work presents the development and characterisation of low-firing thick-film systems (dielectrics, resistors and conductors), formulated to achieve chemical and thermal expansion compatibility with an austenitic stainless steel medical alloy. Adherence tests and results on electrical properties of these systems: resistance, temperature coefficient of resistance (TCR) are presented. It was found that the main issue in these systems lies in mastering the materials interactions during firing, especially at the silver-based resistor terminations. The interaction of silver, resistor and dielectric tends to give rise to highly resistive zones at the terminations, affecting reliability. This can be circumvented by post-firing the resistor terminations at a moderate temperature.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrical and Thermal Properties of Materials · Advanced Sensor Technologies Research · Gas Sensing Nanomaterials and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. C. Jacq, T. Maeder, P. Ryser, J. Europ. Ceramic Soc. 4(6), 1897–1900 (2004)10.1016/S0955-2219(03)00467-9 ↗
2. T. Maeder, H. Birol, C. Jacq, P. Ryser, in Proceedings, European Microelectronics and Packaging Symposium, Prague (CZ), 2004, pp. 272–276
3. N.M. White, Thesis, University of Southampton, Faculty of Engineering & Applied Science (1988)
4. D. Crottet, T. Maeder, D. Fritschy, H. Bleuler, L.P. Nolte, I.P. Pappas, IEEE Trans. Biomed. Eng. 52(9), 1609–1611 (2005)10.1109/TBME.2005.851504 ↗
5. D. Crottet, J. Kowal, S.A. Sarfert, T. Maeder, H. Bleuler, L.P. Nolte, L. Dürselen, J. Biomech. 40(8), 1709–1715 (2007)10.1016/j.jbiomech.2006.08.004 ↗
6. D. Crottet, T. Maeder, S.A. Sarfert, D. Fritschy, H. Bleuler, L.P. Nolte, I.P. Pappas, 51st Annual Meeting of the Meeting of the Orthopaedic Research Society, Washington (USA), (2005)
7. C. Jacq, T. Maeder, S. Martinerie, G. Corradini, E. Carreño-Morelli, P. Ryser, in Proceedings, 4th European Microelectronics and Packaging Symposium, Terme Čatež (SI), IMAPS, 2006, pp. 105–109
8. C. Jacq, S. Vionnet, T. Maeder, P. Ryser, in Proceedings, European Microelectronics and Packaging Symposium, Prague (CZ), 2004, pp. 267–271
9. C. Jacq, T. Maeder, S. Vionnet, P. Ryser, J. Europ. Ceramic Soc. 25(12), 2121–2124 (2005)10.1016/j.jeurceramsoc.2005.03.224 ↗
10. C. Jacq, T. Maeder, S. Menot-Vionnet, H. Birol, I. Saglini, P. Ryser, in Proceedings of the 15th European Microelectronics and Packaging Conference (EMPC), Brugge (BE), IMAPS, 2005, pp. S13.04, 319–324
11. C. Jacq, T. Maeder, N. Johner, G. Corradini, P. Ryser, in Proceedings of the 16th European Microelectronics and Packaging Conference (EMPC), Oulu, (FI), IMAPS, pp. 167–170
12. S. Vionnet-Menot, C. Grimaldi, T. Maeder, P. Ryser, S. Strässler, Phys. Rev. B 71, 064201 (2005)10.1103/PhysRevB.71.064201 ↗
13. M. Prudentiati, B. Morten, B. Forti, A.F. Gualtieri, G.M. Dilliway, Inter. J. Inorg. Mater. 3, 667–674 (2001)10.1016/S1466-6049(01)00193-3 ↗
14. M. Hamezan, H.A.A. Sidek, A.W. Zaidan, K. Kaida, A.T. Zainal, J. Appl. Sci. 6(4), 943–949 (2006)10.3923/jas.2006.943.949 ↗
15. G.E. Rachkovskaya, G.B. Zakharevich, Glass Ceram. 61(1–2), 9–12 (2004)10.1023/B:GLAC.0000026761.65840.58 ↗
16. K. Adachi, H. Kuno, J. Am. Ceramic Soc. 83(10), 2441–2448 (2000)10.1111/j.1151-2916.2000.tb01574.x ↗