Investigation for analytical procedure for determination of trace metallic ions in simulated body fluids by inductively coupled plasma atomic emission spectrometry (ICP-AES)
Source abstract
Abstract
Influences of matrix elements and high viscosity in three kind of simulated body fluids (SBFs) on determination of trace metallic elements (Co, Cr, Ni, Al and V) by inductively coupled plasma atomic emission spectrometry (ICP-AES) were investigated. In addition, decreases of these effects were attempted by H(2)SO(4) fume treatment. Calibration lines of the elements were constructed by the standard solutions made of elemental solutions and HCl or the SBFs. Gradients of calibration lines constructed by the each standard solution were different. Therefore, for accurate determination, calibration curve must be constructed by the elemental standard solution and the analytical solution. Limit of detection (LOD) of each element in the solutions was measured by a blank test. Although LODs of microg [Symbol: see text] L(-1) (ppb) order were nominal instrumental data, because of influences of the matrix elements and the high viscosity, the measured LODs of the elements in the SBFs were higher than those. However, the LODs were lowered by employing the H(2)SO(4)-fume treatment and approached to the nominal instrumental data. Therefore, H(2)SO(4)-fume treatment is extremely effective treatment in order to reduce the influences.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Analytical chemistry methods development · Electrochemical Analysis and Applications · Mass Spectrometry Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. T. HANAWA, In “Recent Research Developments in Biomaterials” edited by Y. Ikada (Reseach Simpost, Kerala, 2002) p. 12.
2. F. W. SUNDERMAN JR, S. M. HOPFER, T. SWIFT, W. N. REZUKA, L. ZIEBKA, P. HIGHMAN, B. EDWARDS, M. FOLICK and H. R. GOSSLING, J. Orthop. Res. 7 (1989) 307.10.1002/jor.1100070302 ↗
3. F. F. HENNIG, H. J. RAITHEL, K. H. SCALLER and J. R. DOHLER, J. Trace. Elem. Electrolyte. Health Dis. 6 (1992) 239.
4. Y. OKAZAKI and E. GOTOH, Biomaterials 26 (2005) 11.10.1016/j.biomaterials.2004.02.005 ↗
5. K. L. WAPER, Clin. Orthop. Relat. Res. 271 (1991) 12.
6. Y. OKAZAKI, S. RAO, S. ASAO, T. TATEISHI, S. KATSUDA and Y. FURUKI, Mater. Trans. JIM. 39 (1998) 1053.10.2320/matertrans1989.39.1053 ↗
7. Y. OKAZAKI and E. NISHIMURA, Mater. Trans. JIM. 41 (2000) 1247.10.2320/matertrans1989.41.1247 ↗
8. Japan Industrial Standard (JIS) No. T 0302, 2000.
9. Japan Industrial Standard (JIS) No. T 0304, 2002.
10. T. ASHINO, K. TAKADA, K. WAGATSUMA and K. ABIKO, METÉRIAUX & TECHNIQUES –N HORS SÉRIE-DÉCEMBRE (2003) 31.10.1051/mattech/200391120031s ↗
11. T. ASHINO and K. TAKADA, Anal. Sci. 9 (1993) 737.10.2116/analsci.9.737 ↗
12. M. ISHIKURO, Bunseki Kagaku 54 (2005) 297.10.2116/bunsekikagaku.54.297 ↗