Coralline hydroxyapatite reinforced with polylactide fibres in lumbar interbody implantation
Source abstract
Abstract
Porous hydroxyapatite HA blocks reinforced with poly-l/dl-lactide fibres were used to maintain the lumbar disc space and to start to create intercorporeal fusion in 23 growing pigs. In four pigs two emptied non adjacent disc spaces were left open. After 3, 6, 12 and 16 weeks the implanted disc blocks were studied radiologically, histologically, histomorphometrically, microradiographically, and with oxytetracycline fluorescence. In plain films slight to moderate ossification of the implanted disc spaces was detected at 12 and 16 weeks. Resorption of the implants was seen radiologically from 3 weeks and fragmentation from 12 weeks onwards. In microradiographs disintegration of the coralline inner structure started at 3 weeks. Histologically, connective tissue ingrowth was seen inside the porous structure from three weeks onwards. Small amounts of new bone were visible and connective tissue inside the implant increased from a mean of 65.6% at 3 weeks to a mean of 79.4% at 16 weeks histomorphometrically. The bone ingrowth varied from 0.7 to 1.7%. A loss of height in the implanted disc spaces was seen (p < 0.05, linear regression analysis). In control pigs the emptied disc spaces lost their height similarly. The implants used were not strong enough to maintain the lumbar disc height.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Spine and Intervertebral Disc Pathology · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. J. SOINI, P. SLÄTIS, M. KANNISTO and J. SANDELIN, Clin. Orthop. 293 (1994) 89.
2. R. HOLMES, Plast. Reconstr. Surg. 63 (1979) 626.10.1097/00006534-197905000-00004 ↗
3. U. HEISE, J. F. OSBORN and F. DUWE, Int. Orthop. 14 (1990) 329.10.1007/BF00178768 ↗
4. M. JARCHO, Clin. Orthop. 157 (1981) 259.10.1097/00003086-198106000-00037 ↗
5. H. J. SENTER, R. KORTYNA and W. R. KEMP, Neurosurgery 25 (1989) 39.10.1227/00006123-198907000-00007 ↗
6. P. YLINEN, J. Mater. Sci. Mater. Med. 5 (1994) 522.10.1007/BF00124884 ↗
7. A. F. TENCER, V. MOONEY, K. L. BROWN and P. M. SILVA, J. Biomed. Mater. Res. 19 (1985) 957.10.1002/jbm.820190807 ↗
8. J. GOLDNER, J. Am. Pathol. 14 (1938) 237.
9. R. W. BUCHOLZ, A. CARLTON and R. E. HOLMES, Orthop. Clin. North. Amer. 18 (1987) 323.10.1016/S0030-5898(20)30395-3 ↗
10. T. J. FLATLEY, K. L. LYNCH and M. BENSON, Clin. Orthop. 179 (1983) 246.10.1097/00003086-198310000-00038 ↗
11. R. J. NASCA, J. E. LEMONS and D. A. DEINLEIN, Orthopedics 12(1989) 543.10.3928/0147-7447-19890401-08 ↗
12. P. RAGNI and T. S. LINDHOLM, Clin. Orthop. 272 (1991) 292.10.1097/00003086-199111000-00044 ↗
13. F. A. PINTAR, D. J. MAIMAN, J. P. HOLLOWELL, N. YOGANANDAN, K. W. DROESE, J. M. REINARTZ and B. CUDDY, Spine 19 (1994) 2524.10.1097/00007632-199411001-00006 ↗
14. T. SHIMA, J. T. KELLER, M. M. ALVIRA, F. H. MAYFIELD and S. B. DUNSKER, J. Neurosurg. 51(1979) 533.10.3171/jns.1979.51.4.0533 ↗
15. D. A. FULLER, S. STEVENSON and S. E. EMERY, Spine 21 (1996) 2131.10.1097/00007632-199609150-00015 ↗
16. T. C. LIN and S. KREBS, Trans Soc Biomat, 12th Ann Meeting 1986, p. 207
17. A. F. TENCER, P. L. WOODARD, J. SWENSON and J. BROWN, Ann. NY. Acad. Sci. 523 (1988) 157.10.1111/j.1749-6632.1988.tb38509.x ↗
18. P. TÖRMÄLÄ, R. TAURIO, M. PELLINEN, P. YLINEN and S. VAINIONPÄ Ä, in Abstract in International New Business and High Tech Research Conference on Development and Applicatons of Advanced Ceramics and P/M Materials 3?5 Sept. 1989, JyvÄ skylÄ, Finland.