journal article·1998-07

Complement activation by cellulose: investigation of the effects of time, area, flow rate, shear rate and temperature on C3a generation in vitro, using a parallel plate flow cell

N. M. K. Lamba, J. D. S. Gaylor, J. M. Courtney, G. D. O. Lowe

Publisher page

Abstract

No abstract is available for this record. The assistant can identify its topic from the title, but cannot infer the study’s results.

Source: Not provided · Quality: missing

Research context

OpenAlex topics: 3D Printing in Biomedical Research · Electrospun Nanofibers in Biomedical Applications · Collagen: Extraction and Characterization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. J. Olijslager, in “Blood compatible materials and their testing”, edited by S. Dawids and A. Bantjes (Martinus Nijhoff, Dordrecht, The Netherlands, 1986) pp. 123–8.
2. H. Klinkmann, in “Biomaterials in Artificial Organs”, edited by J. P. Paul, J. D. S. Gaylor, J. M. Courtney and T. Gilchrist (Macmillan, London, 1984) pp. 1–8.
3. J. M. Courtney, N. M. K. Lamba, S. Sundaram, and C. D. Forbes, Biomaterials 15 (1994) 737.10.1016/0142-9612(94)90026-4 ↗
4. P. D. Richardson, S. F. Mohammad, and R. G. Mason, Proc. Eur. Soc. Artif. Organs 4 (1977) 175.
5. N. Kawagoishi, C. Nojiri, K. Senshu, T. Kido, H. Nagai, T. Kanamori, K. Sakai, H. Koyanagi, and T. Akutsu, Artif. Organs 18 (1994) 588.10.1111/j.1525-1594.1994.tb03383.x ↗
6. T. G. V. Kooten, J. M. Schakenraad, H. C. V. D. Mei, and H. J. Busscher, J. Biomed. Mater. Res. 26 (1992) 725.10.1002/jbm.820260604 ↗
7. S. Usami, H. Chen, Y. Zhao, S. Chien, and R. Skalak, Ann. Biomed. Eng. 21 (1993) 77.10.1007/BF02368167 ↗
8. D. Weng, J. D. S. Gaylor, J. M. Courtney, and G. D. O. Lowe, Artif. Organs 15 (1991) 307.
9. J. S. Hele-Shaw, Nature 588 (1898) 556.
10. D. Weng, unpublished results (1991).
11. L. M. Robertson, J. M. Courtney, L. Irvine, C. Jones, and G.D.O. Lowe, Artif. Organs 14 (1990) 41.10.1111/j.1525-1594.1990.tb01590.x ↗
12. S. Wark, MSc University of Strathclyde, Glasgow (1993) p. 66.
13. G. Chang, D. R. Absolom, A. B. Strong, G. D. Stubley, and W. Zingg, J. Biomed. Mater. Res. 22 (1988) 13.10.1002/jbm.820220104 ↗
14. J. Vienken, and U. Baurmeister, Artif. Organs 11 (1987) 272.10.1111/j.1525-1594.1987.tb02671.x ↗
15. A. Mahiout, H. Meinhold, M. Kessel, M. Schulze, and U. Baurmeister, ibid. 11 (1987) 149.10.1111/j.1525-1594.1987.tb02648.x ↗
16. M. Goldman, N. Lietaer, P. Lambert, C. Thayse, and J.-L. Vanherweghem, Life Support Systems 5 (1987) 317.
17. D. E. Chenoweth, and L. W. Henderson, Artif. Organs 11 (1987) 155.10.1111/j.1525-1594.1987.tb02649.x ↗
18. R. M. Schaefer, W. Rautenberg, S. Neumann, A. Heidland, W. H. HÖrl, Clin. Nephrol. 26 (1986) 535.
19. A. T. Nguyen, C. Lethias, J. Zingraff, A. Herbelin, C. Narel, and B. Descamps-Latscha, Kidney Int. 28 (1985) 158.10.1038/ki.1985.136 ↗
20. L. I. Friedman, and E. F. Leonard, Fed. Proc. 30 (1971) 1641.
21. H. L. Goldsmith, and V. T. Turitto, Thromb. Haemost 55 (1986) 415.10.1055/s-0038-1661576 ↗
22. R. S. Wilson, M. D. Lelah, and S. L. Cooper, in “Techniques of biocompatibility testing”, Vol. 11, (edited by D. F. Williams (CRC Press, Boca Raton, FL, 1986) pp. 151–81.