journal article·2018-11

Influence of super-hydrophobic silicone rubber substrate on the growth and differentiation of human lens epithelial cells

Liuxueying Zhong, Jiayi Jin, Danying Zheng, Weisheng Guan, Yue Guo, Anfu Chen, Yujiang Peng, Qianying Gao, Yongxin Zheng, Hanxiong Huang

Publisher page

Abstract

Materials with low cell adhesion are advantageous for production of replacement intraocular lens (IOL) to prevent posterior capsular opacification (PCO). We evaluated the feasibility of compression molding for manufacture of silicone rubber with super-hydrophobic surface and low cell infiltrative characteristics compared to ordinary hydrophobic silicone rubber. Silicone specimens with complex surface topology (super-hydrophobic) or smooth surfaces (hydrophobic) were manufactured by vacuum deforming and molding. Contact angle, microscopic surface structure, and transparency were evaluated. Super-hydrophobic and smooth samples were compared for effects on proliferation, adhesion, and morphology of human lens epithelial cells (hLECs). Epithelial-mesenchymal transition (EMT) was examined by immunofluorescence expression of fibronectin (Fn), Alpha-smooth muscle actin (α-SMA), and vimentin. The surface contact angle of super-hydrophobic silicone was greater than that of smooth silicone (153.8° vs. 116°). The super-hydrophobic surface exhibited a micron-scale palisade structure under scanning electron microscopy (unit length, width, and height of 80, 25, and 25 μm, respectively). However, cell number per 50 × microscopic field on super-hydrophobic surfaces was markedly reduced 24 and 72 h post-seeding compared to smooth surfaces (p < 0.01). Cells were cuboidal or spherical after 72h on super-hydrophobic surfaces, and exhibited numerous surface microvilli with fluff-base polarity, while cells on smooth surfaces exhibited morphological characteristics of EMT. Expression levels of the α-SMA and vimentin were reduced on super-hydrophobic surfaces compared to smooth surfaces. Super-hydrophobic silicon inhibits proliferation, adhesion, and EMT of hLECs, properties that may prevent fibrosis following cataract surgery.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Intraocular Surgery and Lenses · Ocular Surface and Contact Lens · Surgical Sutures and Adhesives

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Findl O, Buehl W, Bauer P, Sycha T. Interventions for preventing posterior capsule opacification. Cochrane db syst rev. 2007;18(3);CD003738.10.1002/14651858.CD003738.pub2 ↗
2. Clark RA. Potential roles of Fn in cutaneous wound repair. Arch Dermatol. 1988;124:201–206.10.1001/archderm.1988.01670020019010 ↗
3. Marcantonio JM, Vrensen GF. Cell biology of posterior capsular opacification. Eye. 1999;13(Pt 3b):484–488.10.1038/eye.1999.126 ↗
4. Okajima Y, Saika S, Sawa M. Effects of surface modification of intraocular lenses on foreign body reaction. Nippon Ganka Gakkai Zasshi. 2005;109:267–273.
5. Majima K, Majima Y. Shape of lens epithelial cells after intraocular lens implantation. J Cataract Reer Surg. 2001;27:745–752.10.1016/S0886-3350(00)00685-4 ↗
6. Miyake K, Ota I, Miyake S, Maekubo K. Correlation between intraocular lens hydrophilicity and anterior capsule opacification and aqueous flare. J Cataract Reer Surg. 1996;22:764–769.10.1016/S0886-3350(96)80159-3 ↗
7. Wang MC, Woung LC. Digital retroilluminated photography to analyze posterior capsule opacification in eyes with intraocular lenses. J Cataract Reer Surg. 2000;26:56–61.10.1016/S0886-3350(99)00332-6 ↗
8. Barequet IS, Wygnanski‐Jaffe T, Sachs D. Effect of diclofenac versus dexamethasone on posterior capsule opacification. J Cataract Reer Surg. 2004;30:2253–2254.10.1016/j.jcrs.2004.08.029 ↗
9. Lois N, Taylor J, McKinnon AD, Smith GC, van’t Hof R, Forrester JV. Effect of TGF‐beta2 and anti‐TGF‐beta2 antibody in a new in vivo rodent model of posterior capsule opacification. Invest ophth vis sci. 2005;46:4260–4266.10.1167/iovs.05-0168 ↗
10. Walker JL, Wolff IM, Zhang L, Menko AS. Activation of SRC kinases signals induction of posterior capsule opacification. Invest Ophth Vis Sci. 2007;48:2214–2223.10.1167/iovs.06-1059 ↗
11. Yang J, Liu TJ, Lu Y. Effects of bicistronic lentiviral vector‐mediated herpes simplex virus thymidine kinase/ganciclovir system on human lens epithelial cells. Curr Eye. 2007;32:33–42.10.1080/02713680601112793 ↗
12. Malecaze F, Couderc B, de Neuville S, et al. Adenovirus‐mediated suicide gene transduction: feasibility in lens epithelium and in prevention of posterior capsule opacification in rabbits. Hum Gene Ther. 1999;10:2365–2372.10.1089/10430349950017013 ↗
13. Stump RJ, Lovicu FJ, Ang SL, Pandey SK, McAvoy JW. Lithium stabilizes the polarized lens epithelial phenotype and inhibits proliferation, migration, and epithelial mesenchymal transition. Int J Clin Exp Patho. 2006;210:249–257.
14. Fernandez V, Fragoso MA, Billotte C. et al. Efficacy of various drugs in the prevention of posterior capsule opacification: experimental study of rabbit eyes. J Cataract Reer Surg. 2004;30:2598–2605.10.1016/j.jcrs.2004.05.013 ↗
15. Rabsilber TM, Auffarth GU. Pharmacological means to prevent secondary cataract. Klin Monatsbl Auge. 2006;223:559–567.10.1055/s-2006-926859 ↗
16. Tognetto D, Toto L, Ballone E, Ravalico G. Biocompatibility of hydrophilic intraocular lenses. J Cataract Reer Surg. 2002;28:644–651.10.1016/S0886-3350(01)01158-0 ↗
17. Okajima Y, Saika S, Sawa M. Effect of surface coating an acrylic intraocular lens with poly(2‐methacryloyloxyethyl phosphorylcholine) polymer on lens epithelial cell line behavior. J Cataract Reer Surg. 2006;32:666–671.10.1016/j.jcrs.2006.01.039 ↗
18. Shigeta M, Tanaka T, Koike N, Yamakawa N, Usui M. Suppression of fibroblast and bacterial adhesion by MPC coating on acrylic intraocular lenses. J Cataract Reer Surg. 2006;32:859–866.10.1016/j.jcrs.2006.02.010 ↗
19. Ishihara K. Bioinspired phospholipid polymer biomaterials for making high performance artificial organs. Sci Technol Adv Mat. 2016;1:131–138.10.1016/S1468-6996(00)00012-7 ↗
20. Qu C, Yao K, Kou R, Xu Z. Surface modification of poly methyl methacrylate intraocular lens by alpha‐allyl glucoside. Journal Biomed Engineering. 2004;21:115–117.
21. Matsushima H, Iwamoto H, Mukai K, Obara Y. Active oxygen processing for acrylic intraocular lenses to prevent posterior capsule opacification. J Cataract Reer Surg. 2006;32:1035–1040.10.1016/j.jcrs.2006.02.042 ↗
22. Wang YX, Robertson JL, Spillman WB,Jr., Claus RO. Effects of the chemical structure and the surface properties of polymeric biomaterials on their biocompatibility. Pharm Res‐dordr. 2004;21:1362–1373.10.1023/B:PHAM.0000036909.41843.18 ↗
23. Cooke CA, McGimpsey S, Mahon G, Best RM. An in vitro study of human lens epithelial cell adhesion to intraocular lenses with and without a Fn coating. Invest Ophth Vis Sci. 2006;47:2985–2989.10.1167/iovs.05-1275 ↗
24. Yuen C, Williams R, Batterbury M, Grierson I. Modification of the surface properties of a lens material to influence posterior capsular opacification. Clin Exp Ophthalmol. 2006;34:568–574.10.1111/j.1442-9071.2006.01278.x ↗
25. Davidson MR, Mitchell SA, Bradley RH. UV‐ozone modification of plasma‐ polymerised acetonitrile films for enhanced cell attachment. Colloid Surf B. 2004;34:213–219.10.1016/j.colsurfb.2004.01.008 ↗
26. Tanaka T, Shigeta M, Yamakawa N, Usui M. Cell adhesion to acrylic intraocular lens associated with lens surface properties. J Cataract Reer Surg. 2005;31:1648–1651.10.1016/j.jcrs.2004.11.050 ↗
27. Werner L, Mamalis N, Izak AM, et al. Posterior capsule opacification in rabbit eyes implanted with 1‐piece and 3‐piece hydrophobic acrylic intraocular lenses. J Cataract Reer Surg. 2005;31:805–811.10.1016/j.jcrs.2004.06.088 ↗
28. Yamakawa N, Tanaka T, Shigeta M, Hamano M, Usui M. Surface roughness of intraocular lenses and inflammatory cell adhesion to lens surfaces. J Cataract Reer Surg. 2003;29:367–370.10.1016/S0886-3350(02)01459-1 ↗
29. Feng XJ, Jiang L. Design and Creation of Superwetting/Antiwetting Surfaces. Adv Mater. 2006;18:3063–3078.10.1002/adma.200501961 ↗
30. Mylonas G, Prskavec M, Baradaran‐Dilmaghani R, Karnik N, Buehl W, Wirtitsch M. Effect of a single‐piece and a three‐piece acrylic sharp‐edged IOL on posterior capsule opacification. Curr Eye Res. 2013;38:86–90.10.3109/02713683.2012.717242 ↗
31. Liu YQ, Jiang ZX, Gao QY, Ge J, Chen JJ, Cao XW, et al. Technical standards of a foldable capsular vitreous body in terms of mechanical, optical, and biocompatible properties. Artif Organs. 2010;34:836–45.10.1111/j.1525-1594.2010.01006.x ↗
32. Guan W‐S, Huang H‐X, Wang B. Topographic design and application of hierarchical polymer surfaces replicated by microinjection compression molding. J Micromech Microeng. 2013;23:10501010.1088/0960-1317/23/10/105010 ↗
33. Lin X, Ge J, Gao Q. et al. Evaluation of the flexibility, efficacy, and safety of a foldable capsular vitreous body in the treatment of severe retinal detachment. Invest Ophth Vis Sci. 2011;52:374–381.10.1167/iovs.10-5869 ↗
34. Lin P, Lin CW, Mansour R, Gu F. Improving biocompatibility by surface modifìcation techniques on implantable bioelectronics. Biosens Bioelectron. 2013;47:451–460.10.1016/j.bios.2013.01.071 ↗