Energy dispersive analysis (EDX) of a degradable bioactive-glass coating on Ti6Al4V in-vivo
Source abstract
Abstract
The bioactive-glass coating of metallic substrates provides a gradually degrading interface which can be used to favor the bony integration of the implant by the physiologic processes of bone turn-over and remodeling. Twelve New Zealand White rabbits, about 2700 g of weight, were operated by the sagittal insertion of a bioactive-glass coated plate of Ti6Al4V. Retrievals were performed at 4, 8 and 12 weeks. Undecalcified specimens were embedded in methyl-metacrylate and sectioned at 100 microns of thickness. Blocks were grinded and had an electroconductive coating to be examined by scanning electron microscopy (SEM), back scattering electron microscopy (BSEM) and X-ray energy dispersive spectroscopy microanalysis (EDX). EDX allows to evaluate quantitatively the gradual process of coating degradation. Areas of 200 microns in square were analyzed at the interface between bone and coating to determine their elemental composition. Silicon was the key marker for the presence of the glass. Morphological analysis confirms that a tight apposition with bone can be obtained by utilizing the bioactive glass coating of metal. Results of energy dispersive analysis support the mechanism of a gradual degradation of the bioactive glass coating and its integration with bone, since the presence of silicon can be documented within the newly formed bone after the coating has disappeared.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Spine and Intervertebral Disc Pathology · Facial Trauma and Fracture Management
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (7)
Show source-provided references
1. L. L. Hench, R. J. Splinter, W. C. Allen and T. K. Greenlee, J. Biomed. Mat. Res. Symp. (1971) 117.10.1002/jbm.820050611 ↗
2. L. L. Hench and O. H. Andersson, in “An Introduction to Bioceramics”, edited by L. L. Hench et al. (Reed Healthcare Comm, Singapore 1993) p. 41.10.1142/9789814317351_0003 ↗
3. A. Merolli, P. Tranquilli Leali, P. L. Guidi and C. Gabbi, J. Mater. Sci. Mater. Med. 11 (2000) 219.10.1023/A:1008912125171 ↗
4. A. Merolli, P. L. Guidi and P. Tranquilli Leali, Gior It Ortop. Traumatol 22(suppl.) (1996) 119.
5. A. Merolli, P. L. Guidi, L. Giannotta and P. Tranquilli Leali, in “Bioceramics 12”, edited by Ohgushi et al. (World Scientific, Singapore, 1999) p. 597.10.1142/9789814291064_0143 ↗
6. C. Gabbi, A. Cacchioli, B. Locardi and E. Guadagnino, Biomaterials 16 (1995) 515.10.1016/0142-9612(95)91123-G ↗
7. P. Tranquilli Leali, A. Merolli, O. Palmacci, C. Gabbi, A. Cacchioli and G. Gonizzi, J. Mater. Sci. Mater. Med. 5 (1994) 345.10.1007/BF00058960 ↗