The effects of early osseointegration in different implant sites in rabbit tibias
Source abstract
Abstract
The aim of this study was to evaluate the early osseointegration of implants with the same surface treatment in different implant sites in rabbit tibias after 4 weeks. A total of 42 acid-etched implants were implanted in three different sites in the tibia: group A was 2.08 ± 0.18 mm below epiphyseal line; group B was 7.00 ± 0.61 mm below the epiphyseal line; group C was 13.01 ± 1.26 mm below the epiphyseal line. After 4 weeks, the average bone-to-implant contact (BIC) values were as follows: group A, 40.02 ± 4.82 %; group B, 28.20 ± 5.41 %; group C, 20.76 ± 3.10 %. The BIC measurements yielded statistically significant differences among group A, group B and group C (P < 0.01); group A demonstrated the best osseointegration. In the present study, the different implantation sites in the selected 20-mm area demonstrated different early osseointegration; the sites located 7 ± 1.5 mm below the epiphyseal line were best suited for observing the effectiveness of early osseointegration among the three sites. The statistical results of the early osseointegration of implants are therefore affected by the location of the implant sites in this 20-mm area.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Pearce AI, Richards RG, Milz S, Schneider E, Pearce SG. Animal models for implant biomaterial research in bone: a review. Eur Cell Mater. 2007;13:1–10.10.22203/eCM.v013a01 ↗
2. Larsson C, Thomsen P, Lausmaa J, Rodahl M, Kasemo B, Eriksson LE. Bone response to surface-modified titanium implants: studies on electropolished implants with different oxide thickness and morphology. Biomaterials. 1994;15:1062–74.10.1016/0142-9612(94)90092-2 ↗
3. Kim YH, Koak JY, Chang IT, Wenneberg A, Heo SJ. A histomorphometric analysis of the effects of various surface treatment methods on osseointegration. Int J Oral Maxillofac Implants. 2003;18:349–56.
4. Schimandle JH, Boden SD. Spine update. The use of animal models to study spinal fusion. Spine. 1994;19:1998–2006.10.1097/00007632-199409000-00023 ↗
5. Stenport VF, Johansson C, Heo SJ, Aspenberg P. Titanium implants and BMP-7 in bone: an experimental model in the rabbit. J Mater Sci Mater Med. 2003;14:247–54.10.1023/A:1022884724059 ↗
6. Sennerby L, Miyamoto I. Insertion torque and RFA analysis of Tiunite and SLA implants. A study in the rabbit. Appl Osseointegr Res. 2000;1:31–3.
7. Suh JY, Jeung OC, Choi BJ, Park JW. Effects of a novel calcium titanate coating on the osseointegration of blasted endosseous implants in rabbit tibiae. Clin Oral Implants Res. 2007;18:362–9.10.1111/j.1600-0501.2006.01323.x ↗
8. Johansson CB, Han CH, Wennerberg A, Albrektsson T. A quantitative comparison of machined commercially pure titanium and titanium-aluminum-vanadium implants in rabbit bone. Int J Oral Maxillofac Implants. 1998;13(3):315–21.
9. Lee IS, Kim DH, Kim HE, Jung YC, Han CH. Biological performance of calcium phosphate films formed on commercially pure Ti by electron-beam evaporation. Biomaterials. 2002;23:609–15.10.1016/S0142-9612(01)00147-8 ↗
10. Le Guehennec L, Goyenvalle E, Aguado E, Houchmand-Cuny M, Enkel B, Pilet P, Daculsi G, Layrolle P. Small-animal models for testing macroporous ceramic bone substitutes. J Biomed Mater Res B Appl Biomater. 2005;72:69–78.10.1002/jbm.b.30118 ↗
11. Lu JX, Gallur A, Flautre B, Anselme K, Descamps M, Thierry B, Hardouin P. Comparative study of tissue reactions to calcium phosphate ceramics among cancellous, cortical, and medullar bone sites in rabbits. J Biomed Mater Res. 1998;42:357–67.10.1002/(SICI)1097-4636(19981205)42:3<357::AID-JBM3>3.0.CO;2-I ↗
12. Choi JW, Heo SJ, Koak JY, Kim SK, Lim YJ, Kim SH, Lee JB. Biological responses of anodized titanium implants under different current voltages. J Oral Rehabil. 2006;33:889–97.10.1111/j.1365-2842.2006.01669.x ↗
13. Peraire C, Arias JL, Bernal D, Pou J, León B, Arañó A, Roth W. Biological stability and osteoconductivity in rabbit tibia of pulsed laser deposited hydroxylapatite coatings. J Biomed Mater Res A. 2006;77(2):370–9.10.1002/jbm.a.30556 ↗
14. Rong M, Zhou L, Gou Z, Zhu A, Zhou D. The early osseointegration of the laser-treated and acid-etched dental implants surface: an experimental study in rabbits. J Mater Sci Mater Med. 2009;20:1721–8.10.1007/s10856-009-3730-4 ↗
15. Dong-Sheng W. Modified method of making ground section of bone with dental implant. Chin J Prosthodont Chin J Prosthodont. 2006;3:169–70.
16. Li LH, Kong YM, Kim HW, Kim YW, Kim HE, Heo SJ, Koak JY. Improved biological performance of Ti implants due to surface modification by micro-arc oxidation. Biomaterials. 2004;25(14):2867–75.10.1016/j.biomaterials.2003.09.048 ↗
17. Hayes JS, Welton JL, Wieling R, Richards RG. In vivo evaluation of defined polished titanium surfaces to prevent soft tissue adhesion. J Biomed Mater Res B Appl Biomater. 2012;100(3):611–7.10.1002/jbm.b.31967 ↗
18. Cho SA, Jung SK. A removal torque of the laser-treated titanium implants in rabbit tibia. Biomaterials. 2003;24:4859–63.10.1016/S0142-9612(03)00377-6 ↗
19. Mori H, Manabe M, Kurachi Y, Nagumo M. Osseointegration of dental implants in rabbit bone with low mineral density. J Oral Maxillofac Surg. 1997;55:351–61.10.1016/S0278-2391(97)90124-5 ↗
20. Cheng Z, Zhang F, He F, Zhang L, Guo C, Zhao S, Yang G. Osseointegration of titanium implants with a roughened surface containing hydride ion in a rabbit model. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010;110(1):e5–12.10.1016/j.tripleo.2010.03.012 ↗
21. Yang GL, He FM, Yang XF, Wang XX, Zhao SF. Bone responses to titanium implants surface-roughened by sandblasted and double etched treatments in a rabbit model. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;106:516–24.10.1016/j.tripleo.2008.03.017 ↗
22. Annibali S, Ripari M, La Monaca G, Tonoli F, Cristalli MP. Local accidents in dental implant surgery: prevention and treatment. Int J Periodontics Restorative Dent. 2009;29:325–31.
23. Annibali S, Ripari M, Lamonaca G, Tonoli F, Cristalli MP. Local complications in dental implant surgery: prevention and treatment. Oral Implantol. 2008;1:21–33.
24. Lioubavina-Hack N, Lang NP, Karring T. Significance of primary stability for osseointegration of dental implants. Clin Oral Implants Res. 2006;17:244–50.10.1111/j.1600-0501.2005.01201.x ↗
25. Franchi M, Orsini E, Trire A, Quaranta M, Martini D, Piccari GG, Ruggeri A, Ottani V. Osteogenesis and morphology of the peri-implant bone facing dental implants. Sci World J. 2004;4:1083–95.10.1100/tsw.2004.211 ↗
26. Ferguson SJ, Langhoff JD, Voelter K, et al. Biomechanical comparison of different surface modifications for dental implants. Int J Oral Maxillofac Implants. 2008;23:1037–46.
27. Botticelli D, Berglundh T, Lindhe J. The influence of a biomaterial on the closure of a marginal hard tissue defect adjacent to implant: an experimental study in the dog. Clin Oral Implants Res. 2004;15:285–92.10.1046/j.1600-0501.2003.01008.x ↗
28. Abrahamsson I, Albouy JP, Berglundh T. Healing at fluoride-modified implants placed in wide marginal defects: an experimental study in dogs. Clin Oral Implants Res. 2008;19:153–9.10.1111/j.1600-0501.2007.01454.x ↗
29. Germanier Y, Tosatti S, Broggini N, Textor M, Buser D. Enhanced bone apposition around biofunctionalized sandblasted and acid-etched titanium implant surfaces. A histomorphometric study in miniature pigs. Clin Oral Implants Res. 2006;17:251–7.10.1111/j.1600-0501.2005.01222.x ↗
30. Lang NP. Healing sequences during tissue integration of ITI implants-analysis of early morphogenesis. The international Team for Implantology 2007 China Symposium, Fuzhou, 8–9 Sept 2007.