Interface micromechanics of transverse sections from retrieved cemented hip reconstructions: an experimental and finite element comparison
Source abstract
Abstract
In finite element analysis (FEA) models of cemented hip reconstructions, it is crucial to include the cement-bone interface mechanics. Recently, a micromechanical cohesive model was generated which reproduces the behavior of the cement-bone interface. The goal was to investigate whether this cohesive model was directly applicable on a macro level. From transverse sections of retrieved cemented hip reconstructions, two FEA-models were generated. The cement-bone interface was modeled with cohesive elements. A torque was applied and the cement-bone interface micromotions, global stiffness and stem translation were monitored. A sensitivity analysis was performed to investigate whether the cohesive model could be improved. All results were compared with experimental findings. That the original cohesive model resulted in a too compliant macromechanical response; the motions were too large and the global stiffness too small. When the cohesive model was modified, the match with the experimental response improved considerably.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Composite Material Mechanics · Elasticity and Material Modeling
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Hailer NP, Garellick G, Karrholm J. Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register. Acta Orthop. 2010;81:34–41.10.3109/17453671003685400 ↗
2. Goto K, Kawanabe K, Kowalski R, Baker D, Nakamura T. Bonding ability evaluation of bone cement on the cortical surface of rabbit’s tibia. J Mater Sci Mater Med. 2010;21:139–46.10.1007/s10856-009-3861-7 ↗
3. Oonishi H, Ohashi H, Oonishi H Jr, Kim SC. THA with hydroxyapatite granules at cement–bone interface: 15- to 20-year results. Clin Orthop Relat Res. 2008;466:373–9.10.1007/s11999-007-0057-7 ↗
4. Lucksanasombool P, Higgs WA, Ignat M, Higgs RJ, Swain MV. Comparison of failure characteristics of a range of cancellous bone–bone cement composites. J Biomed Mater Res A. 2003;64:93–104.10.1002/jbm.a.10361 ↗
5. Waanders D, Janssen D, Mann KA, Verdonschot N. The mechanical effects of different levels of cement penetration at the cement–bone interface. J Biomech. 2010;43:1167–75.10.1016/j.jbiomech.2009.11.033 ↗
6. Mann KA, Miller MA, Verdonschot N, Izant TH, Race A. Functional interface micromechanics of 11 en-bloc retrieved cemented femoral hip replacements. Acta Orthop. 2010;81:308–17.10.3109/17453674.2010.480938 ↗
7. Bishop NE, Schoenwald M, Schultz P, Puschel K, Morlock MM. The condition of the cement mantle in femoral hip prosthesis implantations–a post mortem retrieval study. Hip Int. 2009;19:87–95.10.1177/112070000901900202 ↗
8. Venesmaa PK, Kroger HP, Jurvelin JS, Miettinen HJ, Suomalainen OT, Alhava EM. Periprosthetic bone loss after cemented total hip arthroplasty: a prospective 5-year dual energy radiographic absorptiometry study of 15 patients. Acta Orthop Scand. 2003;74:31–6.10.1080/00016470310013617 ↗
9. Miller MA, Eberhardt AW, Cleary RJ, Verdonschot N, Mann KA. Micromechanics of postmortem-retrieved cement–bone interfaces. J Orthop Res. 2010;28:170–7.10.1002/jor.20893 ↗
10. Stolk J, Janssen D, Huiskes R, Verdonschot N. Finite element-based preclinical testing of cemented total hip implants. Clin Orthop Relat Res. 2007;456:138–47.10.1097/BLO.0b013e31802ba491 ↗
11. Hung JP, Chen JH, Chiang HL, Wu JS. Computer simulation on fatigue behavior of cemented hip prostheses: a physiological model. Comput Methods Programs Biomed. 2004;76:103–13.10.1016/j.cmpb.2004.05.004 ↗
12. Katoozian H, Davy DT. Effects of loading conditions and objective function on three-dimensional shape optimization of femoral components of hip endoprostheses. Med Eng Phys. 2000;22:243–51.10.1016/S1350-4533(00)00030-8 ↗
13. Afsharpoya B, Barton DC, Fisher J, Purbach B, Wroblewski M, Stewart TD. Cement mantle stress under retroversion torque at heel-strike. Med Eng Phys. 2009;31:1323–30.10.1016/j.medengphy.2009.09.006 ↗
14. Lewis G, Duggineni R. Finite element analysis of a three-dimensional model of a proximal femur-cemented femoral THJR component construct: influence of assigned interface conditions on strain energy density. Bio-Med Mater Eng. 2006;16:319–27.
15. Colombi P. Fatigue analysis of cemented hip prosthesis: model definition and damage evolution algorithms. Int J Fatigue. 2002;24:895–901.10.1016/S0142-1123(01)00203-1 ↗
16. Verdonschot N, Huiskes R. The effects of cement-stem debonding in THA on the long-term failure probability of cement. J Biomech. 1997;30:795–802.10.1016/S0021-9290(97)00038-9 ↗
17. Mann KA, Miller MA, Cleary RJ, Janssen D, Verdonschot N. Experimental micromechanics of the cement–bone interface. J Orthop Res. 2008;26:872–9.10.1002/jor.20575 ↗
18. Waanders D, Janssen D, Mann KA, Verdonschot N. The behavior of the micro-mechanical cement–bone interface affects the cement failure in total hip replacement. J Biomech. 2011;44:228–34.10.1016/j.jbiomech.2010.10.020 ↗
19. Perez MA, Palacios J. Comparative finite element analysis of the debonding process in different concepts of cemented hip implants. Ann Biomed Eng. 2010;38:2093–106.10.1007/s10439-010-9996-3 ↗
20. Moreo P, Perez MA, Garcia-Amar JM, Doblare M. Modelling the mixed-mode failure of cement–bone interfaces. Eng Fract Mech. 2006;73:1379–95.10.1016/j.engfracmech.2006.01.005 ↗
21. Mann KA, Damron LA. Predicting the failure response of cement–bone constructs using a non-linear fracture mechanics approach. J Biomech Eng. 2002;124:462–70.10.1115/1.1488167 ↗
22. Alfano G, Crisfield MA. Finite element interface models for the delamination analysis of laminated composites: mechanical and computational issues. Int J Numer Methods Eng. 2001;50:1701–36.10.1002/nme.93 ↗
23. Wang JY, Tozzi G, Chen J, Contal F, Lupton C, Tong J. Bone–cement interfacial behaviour under mixed mode loading conditions. J Mech Behav Biomed Mater. 2010;3:392–8.10.1016/j.jmbbm.2010.03.001 ↗
24. Mann KA, Mocarski R, Damron LA, Allen MJ, Ayers DC. Mixed-mode failure response of the cement–bone interface. J Orthop Res. 2001;19:1153–61.10.1016/S0736-0266(01)00036-5 ↗
25. Waanders D, Janssen D, Bertoldi K, Mann KA, Verdonschot N. Mixed-mode loading of the cement–bone interface: a finite element study. Comput Methods Biomech Biomed Eng. 2011;14:145–55.10.1080/10255842.2010.535814 ↗
26. Waanders D, Janssen D, Mann KA, Verdonschot N. Morphology based cohesive zone modeling of the cement–bone interface from postmortem retrievals. J Mech Behav Biomed Mater. 2011;4:1492–503.10.1016/j.jmbbm.2011.05.019 ↗
27. Bergmann G, Graichen F, Rohlmann A. Is staircase walking a risk for the fixation of hip implants? J Biomech. 1995;28:535–53.10.1016/0021-9290(94)00105-D ↗
28. Douglas D, Peucker T. Algorithms for the reduction of the number of points required to represent a digitized line or its caricature. Can Cartogr. 1973;10:112–22.10.3138/FM57-6770-U75U-7727 ↗
29. Janssen D, Mann KA, Verdonschot N. Micro-mechanical modeling of the cement–bone interface: the effect of friction, morphology and material properties on the micromechanical response. J Biomech. 2008;41:3158–63.10.1016/j.jbiomech.2008.08.020 ↗
30. Harper EJ, Bonfield W. Tensile characteristics of ten commercial acrylic bone cements. J Biomed Mater Res. 2000;53:605–16.10.1002/1097-4636(200009)53:5<605::AID-JBM22>3.0.CO;2-5 ↗
31. Lewis G. Properties of acrylic bone cement: state of the art review. J Biomed Mater Res. 1997;38:155–82.10.1002/(SICI)1097-4636(199722)38:2<155::AID-JBM10>3.0.CO;2-C ↗
32. Zar JH. Biostatistical analysis. 5th ed. Upper Saddle River: Pearson Prentice Hall; 2010.
33. Mann KA, Gupta S, Race A, Miller MA, Cleary RJ. Application of circular statistics in the study of crack distribution around cemented femoral components. J Biomech. 2003;36:1231–4.10.1016/S0021-9290(03)00091-5 ↗
34. Ural A. Prediction of Colles’ fracture load in human radius using cohesive finite element modeling. J Biomech. 2009;42:22–8.10.1016/j.jbiomech.2008.10.011 ↗
35. Salomonsson K, Andersson T. Modeling and parameter calibration of an adhesive layer at the meso level. Mech Mater. 2008;40:48–65.10.1016/j.mechmat.2007.06.004 ↗
36. Zelle J, Janssen D, Peeters S, Brouwer C, Verdonschot N. Mixed-mode failure strength of implant–cement interface specimens with varying surface roughness. J Biomech. 2011;44:780–3.10.1016/j.jbiomech.2010.10.037 ↗
37. Miller MA, Race A, Waanders D, Cleary RJ, Janssen D, Verdonschot N, Mann KA. Multi-axial loading micromechanics of the cement–bone interface in post-mortem retrievals and lab-prepared specimens. J Mech Behav Biomed Mater. 2011;4:366–74.10.1016/j.jmbbm.2010.11.004 ↗
38. Sundfeldt M, Carlsson LV, Johansson CB, Thomsen P, Gretzer C. Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthop. 2006;77:177–97.10.1080/17453670610045902 ↗