Flexor tendon healing within the tendon sheath using bioabsorbable poly-l/d-lactide 96/4 suture. A histological in vivo study with rabbits
Source abstract
Abstract
The bioabsorbable poly-L/D-lactide (PLDLA) 96/4 suture has good biomechanical and knot properties, and sufficient tensile strength half-life for flexor tendon repair. In the present study, the biocompatibility of PLDLA suture was compared with that of coated braided polyester suture in the rabbit flexor digitorum profundus tendon repaired within the tendon sheath. Postoperative unrestricted active mobilization was allowed. The tendons were studied histologically after 1-, 3-, 6-, 12-, 26-, and 52-week follow-ups. No differences were found in the biocompatibility between the suture materials, with only scattered multinuclear giant cells near the sutures in both groups from 6 weeks onwards. At 52 weeks, most of the PLDLA material was absorbed and the histological structure of the tendon appeared normal, whereas in the polyester repairs the suture knots filled the repair site, causing bulking of the tendon surface, and the collagen alignment appeared disoriented. The results suggest that the PLDLA 96/4 is a suitable suture material for flexor tendon repair.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Tendon Structure and Treatment · Orthopedic Surgery and Rehabilitation · Surgical Sutures and Adhesives
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Lawrence TM, Davis TRC. A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair. J Hand Surg. 2005;30A:836–41.10.1016/j.jhsa.2005.03.011 ↗
2. Viinikainen A, Göransson H, Huovinen K, et al. Material and knot properties of braided polyester (Ticron®) and bioabsorbable poly-l/-d-lactide (PLDLA) 96/4 sutures. J Mater Sci Mater Med. 2006;17:169–77.10.1007/s10856-006-6821-5 ↗
3. Mashadi ZB, Amis AA. Variation of holding strength of synthetic absorbable flexor tendon sutures with time. J Hand Surg. 1992;17B:278–81.10.1016/0266-7681(92)90115-I ↗
4. Wada A, Kubota H, Akiyama T, et al. Effect of absorbable polydioxanone flexor tendon repair and restricted active mobilization in a canine model. J Hand Surg. 2001;26A:398–406.10.1053/jhsu.2001.24134 ↗
5. Wada A, Kubota H, Taketa M, et al. Comparison of the mechanical properties of polyglycolidetrimethylene carbonate (Maxon) and polydioxanone sutures (PDS2) used for flexor tendon repair and active mobilization. J Hand Surg. 2002;27B:329–32.10.1054/jhsb.2002.0767 ↗
6. Kangas J, Paasimaa S, Mäkelä P, et al. Comparison of strength properties of poly-l/d-lactide (PLDLA) 96/4 and polyglyconate (Maxon®) sutures: in vitro, in the subcutis, and in the Achilles tendon of rabbits. J Biomed Mater Res. 2001;58:121–6.10.1002/1097-4636(2001)58:1<121::AID-JBM180>3.0.CO;2-Z ↗
7. Kangas J, Pajala A, Leppilahti J, et al. Histomorphometric analysis of poly-l/d-lactide 96/4 sutures in the gastrocnemius tendon of rabbits. Int J Artif Organs. 2006;29:893–9.10.1177/039139880602900910 ↗
8. Viinikainen A, Göransson H, Ryhänen J. Primary flexor tendon repair techniques. Scand J Surg. 2008;97:333–40.10.1177/145749690809700410 ↗
9. Viinikainen A, Göransson H, Huovinen K, et al. Bioabsorbable poly-l/d-lactide (PLDLA) 96/4 triple-stranded bound suture in the modified Kessler repair: ex vivo static and cyclic tensile testing study in a porcine extensor tendon model. J Mater Sci Mater Med. 2009;20:1963–9.10.1007/s10856-009-3747-8 ↗
10. Saikku-Bäkström A, Tulamo RM, Räihä JE, et al. Intramedullary fixation of cortical bone osteotomies with absorbable self-reinforced fibrillated poly-96l/4d-lactide (SR-PLA96) rods in rabbits. Biomaterials. 2001;22:33–43.10.1016/S0142-9612(00)00142-3 ↗
11. Jones ME, Ladhani K, Mudera V, et al. Flexor tendon blood vessels. J Hand Surg. 2000;25B:552–9.10.1054/jhsb.2000.0458 ↗
12. Matthews P, Richards H. The repair potential of digital flexor tendons. An experimental study. J Bone Joint Surg. 1974;56B:618–25.10.1302/0301-620X.56B4.618 ↗
13. Matthews P, Richards H. Factors in the adherence of flexor tendon after repair. J Bone Joint Surg. 1976;58B:230–6.10.1302/0301-620X.58B2.777010 ↗
14. Zhao C, Amadio PC, Momose T, et al. The effect of suture technique on adhesion formation after flexor tendon repair for partial lacerations in a canine model. J Trauma. 2001;51:917–21.10.1097/00005373-200111000-00015 ↗
15. Zhao C, Amadio PC, Momose T, et al. Effect of synergistic wrist motion on adhesion formation after repair of partial flexor digitorum profundus tendon lacerations in a canine model in vivo. J Bone Joint Surg. 2002;84A:78–84.10.2106/00004623-200201000-00012 ↗
16. Pennington DG. The locking loop tendon suture. Plast Reconstr Surg. 1979;63:648–52.10.1097/00006534-197905000-00007 ↗
17. Small JO, Brennen MD, Colville J. Early active mobilisation following flexor tendon repair in zone 2. J Hand Surg. 1989;14B:383–91.10.1016/0266-7681(89)90152-6 ↗
18. Bainbridge LC, Robertson C, Gillies D, et al. A Comparison of post-operative mobilization of flexor tendon repairs with “passive flexion-active extension” and “controlled active motion” techniques. J Hand Surg. 1994;19B:517–21.10.1016/0266-7681(94)90219-4 ↗
19. Kubota H, Miyanishi K, Hoshino S, et al. Effect of a new repair technique on biomechanical properties of canine flexor tendons—in vitro study. Hand Surg. 1998;3:247–55.10.1142/S0218810498000349 ↗
20. Hatanaka H, Manske PR. Effect of suture size on locking and grasping flexor tendon repair techniques. Clin Orthop Rel Res. 2000;1:267–74.10.1097/00003086-200006000-00032 ↗
21. Viinikainen A, Göransson H, Huovinen K, et al. A comparative analysis of the biomechanical behaviour of five flexor tendon core sutures. J Hand Surg. 2004;29B:536–43.10.1016/j.jhsb.2004.05.007 ↗
22. Trail IA, Powell ES, Noble J. An evaluation of suture materials used in tendon surgery. J Hand Surg. 1989;14B:422–7.10.1016/0266-7681(89)90160-5 ↗
23. Bourne RB, Bitar H, Andreae PR, et al. In-vivo comparison of four absorbable sutures: Vicryl, Dexon Plus, Maxon and PDS. Can J Surg. 1988;31:43–5.
24. O′Broin ES, Earley MJ, Smyth H, et al. Absorbable sutures in tendon repair. A comparison of PDS with prolene in rabbit tendon repair. J Hand Surg. 1993;20B:505–8.
25. Saikku-Bäkström A, Tulamo RM, Pohjonen T, et al. Material properties of absorbable self-reinforced fibrillated poly-96l/4d-lactide (SR-PLA96) rods; a study in vitro and in vivo. J Mater Sci Mater Med. 1999;10:1–8.10.1023/A:1008828925090 ↗
26. Cordewener FW, Rozema FR, Bos RRM, et al. Material properties and tissue reaction during degradation of poly (96l/4d-lactide)—a study in vitro and in rats. J Mater Sci Mater Med. 1995;6:211–7.10.1007/BF00146858 ↗
27. Pietrzak WS, Sarver DR, Verstynen ML. Bioabsorbable polymer science fort he practising surgeon. J Craniofac Surg. 1997;8:87–91.10.1097/00001665-199703000-00004 ↗
28. Törmälä P, Rokkanen P. Bioabsorbable implants in the fixation of fractures. Review. Ann Chir Gyn. 2001;90:81–5.
29. Gelberman RH, VandeBerg JS, Manske PR, et al. The early stages of flexor tendon healing: a morphologic study of the first fourteen days. J Hand Surg. 1985;10A:776–84.10.1016/S0363-5023(85)80151-9 ↗
30. Khan U, Edwards JCW, McGrouther DA. Patterns of cellular activation after tendon injury. J Hand Surg. 1996;21B:813–20.10.1016/S0266-7681(96)80199-9 ↗
31. Chow SP, Yu OD. An experimental study on incompletely cut chicken tendons—a comparison of two methods of management. J Hand Surg. 1984;9B:121–5.10.1016/S0266-7681(84)80006-6 ↗
32. Wong JKF, Cerovac S, Ferguson MWJ, et al. The cellular effect of a single interrupted suture on tendon. J Hand Surg. 2006;31B:358–67.10.1016/j.jhsb.2006.03.162 ↗