journal article·2018-07Open access

Three-dimensional modeling of removal torque and fracture progression around implants

Kohei Murase, Patrik Stenlund, Peter Thomsen, Jukka Lausmaa, Anders Palmquist

Abstract

In the present study, a model for simulations of removal torque experiments was developed using finite element method. The interfacial retention and fracturing of the surrounding material caused by the surface features during torque was analyzed. It was hypothesized that the progression of removal torque and the phases identified in the torque response plot represents sequential fractures at the interface. The 3-dimensional finite element model fairly accurately predicts the torque required to break the fixation of acid-etched implants, and also provides insight to how sequential fractures progress downwards along the implant side.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Branemark PI, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1–132.
2. Parel SM, Branemark PI, Jansson T. Osseointegration in maxillofacial prosthetics .1. Intraoral applications. J Prosthet Dent. 1986;55:490–4. https://doi.org/10.1016/0022-3913(86)90184-8.10.1016/0022-3913(86)90184-8. ↗
3. Parel SM, Branemark PI, Tjellstrom A, Gion G. Osseointegration in maxillofacial prosthetics. 2. Extraoral applications. J Prosthet Dent. 1986;55:600–6. https://doi.org/10.1016/0022-3913(86)90040-5.10.1016/0022-3913(86)90040-5. ↗
4. Branemark R, Berlin O, Hagberg K, Bergh P, Gunterberg B, Rydevik B. A novel osseointegrated percutaneous prosthetic system for the treatment of patients with transfemoral amputation: A prospective study of 51 patients. Bone Jt J. 2014;96-B:106–13. https://doi.org/10.1302/0301-620X.96B1.31905.10.1302/0301-620X.96B1.31905. ↗
5. Astrand P, Ahlqvist J, Gunne J, Nilson H. Implant treatment of patients with edentulous jaws: a 20-year follow-up. Clin Implant Dent Relat Res. 2008;10:207–17. https://doi.org/10.1111/j.1708-8208.2007.00081.x.10.1111/j.1708-8208.2007.00081.x. ↗
6. Lekholm U, Grondahl K, Jemt T. Outcome of oral implant treatment in partially edentulous jaws followed 20 years in clinical function. Clin Implant Dent Relat Res. 2006;8:178–86. https://doi.org/10.1111/j.1708-8208.2006.00019.x.10.1111/j.1708-8208.2006.00019.x. ↗
7. Albrektsson T, Wennerberg A. Oral implant surfaces: Part 1-review focusing on topographic and chemical properties of different surfaces and in vivo responses to them. Int J Prosthodont. 2004;17:536–43.
8. Omar O, Lenneras M, Svensson S, Suska F, Emanuelsson L, Hall J, et al. Integrin and chemokine receptor gene expression in implant-adherent cells during early osseointegration. J Mater Sci Mater Med. 2010;21:969–80. https://doi.org/10.1007/s10856-009-3915-x.10.1007/s10856-009-3915-x. ↗
9. Omar O, Svensson S, Zoric N, Lenneras M, Suska F, Wigren S, et al. In vivo gene expression in response to anodically oxidized versus machined titanium implants. J Biomed Mater Res A. 2010;92:1552–66. https://doi.org/10.1002/jbm.a.32475.10.1002/jbm.a.32475. ↗
10. Lennerås M, Palmquist A, Norlindh B, Emanuelsson L, Thomsen P, Omar O. Oxidized titanium implants enhance osseointegration via mechanisms involving RANK/RANKL/OPG regulation. Clin Implant Dent Relat Res. 2015;17:e486–500. https://doi.org/10.1111/cid.12276.10.1111/cid.12276. ↗
11. Branemark R, Ohrnell LO, Nilsson P, Thomsen P. Biomechanical characterization of osseointegration during healing: an experimental in vivo study in the rat. Biomaterials. 1997;18:969–78.10.1016/S0142-9612(97)00018-5 ↗
12. Stenport VF, Johansson CB. Evaluations of bone tissue integration to pure and alloyed titanium implants. Clin Implant Dent Relat Res. 2008;10:191–9. https://doi.org/10.1111/j.1708-8208.2007.00077.x.10.1111/j.1708-8208.2007.00077.x. ↗
13. Branemark R, Emanuelsson L, Palmquist A, Thomsen P. Bone response to laser-induced micro- and nano-size titanium surface features. Nanomed. 2011;7:220–7. https://doi.org/10.1016/j.nano.2010.10.006.10.1016/j.nano.2010.10.006. ↗
14. Palmquist A, Emanuelsson L, Branemark R, Thomsen P. Biomechanical, histological and ultrastructural analyses of laser micro- and nano-structured titanium implant after 6 months in rabbit. J Biomed Mater Res B Appl Biomater. 2011;97:289–98. https://doi.org/10.1002/jbm.b.31814 .10.1002/jbm.b.31814 ↗
15. Le Guehennec L, Soueidan A, Layrolle P, Amouriq Y. Surface treatments of titanium dental implants for rapid osseointegration. Dent Mater. 2007;23:844–54. https://doi.org/10.1016/j.dental.2006.06.025 .10.1016/j.dental.2006.06.025 ↗
16. Shalabi MM, Gortemaker A, Van’t Hof MA, Jansen JA, Creugers NH. Implant surface roughness and bone healing: a systematic review. J Dent Res. 2006;85:496–500.10.1177/154405910608500603 ↗
17. Eliasson A, Blomqvist F, Wennerberg A, Johansson A. A retrospective analysis of early and delayed loading of full-arch mandibular prostheses using three different implant systems: clinical results with up to 5 years of loading. Clin Implant Dent Relat Res. 2009;11:134–48. https://doi.org/10.1111/j.1708-8208.2008.00099.x .10.1111/j.1708-8208.2008.00099.x ↗
18. Elias CN, Oshida Y, Lima JHC, Muller CA. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque. J Mech Behav Biomed Mater. 2008;1:234–42. https://doi.org/10.1016/j.jmbbm.2007.12.002.10.1016/j.jmbbm.2007.12.002. ↗
19. Omar OM, Lenneras ME, Suska F, Emanuelsson L, Hall JM, Palmquist A, et al. The correlation between gene expression of proinflammatory markers and bone formation during osseointegration with titanium implants. Biomaterials. 2011;32:374–86. https://doi.org/10.1016/j.biomaterials.2010.09.011 .10.1016/j.biomaterials.2010.09.011 ↗
20. Butz F, Aita H, Wang CJ, Ogawa T. Harder and stiffer bone osseointegrated to roughened titanium. J Dent Res. 2006;85:560–5.10.1177/154405910608500616 ↗
21. Stenlund P, Murase K, Stalhandske C, Lausmaa J, Palmquist A. Understanding mechanisms and factors related to implant fixation; a model study of removal torque. J Mech Behav Biomed Mater. 2014;34C:83–92. https://doi.org/10.1016/j.jmbbm.2014.02.006.10.1016/j.jmbbm.2014.02.006. ↗
22. Hansson S, Löberg J, Mattisson I, Ahlberg E. Global biomechanical model for dental implants. J Biomech. 2011;44:1059–65. https://doi.org/10.1016/j.jbiomech.2011.02.002.10.1016/j.jbiomech.2011.02.002. ↗
23. Ellingsen JE, Johansson CB, Wennerberg A, Holmen A. Improved retention and bone-to-implant contact with fluoride-modified titanium implants. Int J Oral Maxillofac Implants. 2004;19:659–66.
24. Van Staden RC, Guan H, Loo YC. Application of the finite element method in dental implant research. Comput Methods Biomech Biomed Engin. 2006;9:257–70. https://doi.org/10.1080/10255840600837074.10.1080/10255840600837074. ↗
25. Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent. 2001;85:585–98. https://doi.org/10.1067/mpr.2001.115251 .10.1067/mpr.2001.115251 ↗
26. Bahrami B, Shahrbaf S, Mirzakouchaki B, Ghalichi F, Ashtiani M, Martin N. Effect of surface treatment on stress distribution in immediately loaded dental implants—A 3D finite element analysis. Dent Mater. 2014;30:e89–97. https://doi.org/10.1016/j.dental.2014.01.012.10.1016/j.dental.2014.01.012. ↗
27. Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2003;18:357–68.
28. Simmons CA, Meguid SA, Pilliar RM. Differences in osseointegration rate due to implant surface geometry can be explained by local tissue strains. J Orthop Res. 2001;19:187–94. https://doi.org/10.1016/S0736-0266(00)90006-8 .10.1016/S0736-0266(00)90006-8 ↗
29. Federer W. Handbook of ceramics and composites: Synthesis and properties. New York: Taylor & Francis; 1990.
30. Wennerberg A, Albrektsson T, Andersson B, Krol JJ. A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clin Oral Implants Res. 1995;6:24–30.10.1034/j.1600-0501.1995.060103.x ↗
31. Stenlund P, Omar O, Brohede U, Norgren S, Norlindh B, Johansson A, et al. Bone response to a novel Ti-Ta-Nb-Zr alloy. Acta Biomater. 2015;20:165–75. https://doi.org/10.1016/j.actbio.2015.03.038.10.1016/j.actbio.2015.03.038. ↗
32. Hansson S, Löberg J, Mattisson I, Ahlberg E. Characterisation of titanium dental implants. II: Local biomechanical model. Open Biomater J. 2010;2:36–52. https://doi.org/10.2174/1876502501002010036.10.2174/1876502501002010036. ↗
33. Palmquist A, Engqvist H, Lausmaa J, Thomsen P. Commercially available dental implants: Review of their surface characteristics. J Biomater Tissue Eng. 2012;2:112–24. https://doi.org/10.1166/jbt.2012.1033.10.1166/jbt.2012.1033. ↗
34. Gadelmawla ES, Koura MM, Maksoud TMA, Elewa IM, Soliman HM. Roughness parameters. J Mater Process Technol. 2002;123:133–45.10.1016/S0924-0136(02)00060-2 ↗
35. Wennerberg A, Ohlsson R, Rosen BG, Andersson B. Characterizing three-dimensional topography of engineering and biomaterial surfaces by confocal laser scanning and stylus techniques. Med Eng Phys. 1996;18:548–56. https://doi.org/10.1016/1350-4533(95)00005-4 .10.1016/1350-4533(95)00005-4 ↗
36. Wennerberg A, Albrektsson T. Suggested guidelines for the topographic evaluation of implant surfaces. Int J Oral Maxillofac Implants. 2000;15:331–44.
37. Hansson S, Norton M. The relation between surface roughness and interfacial shear strength for bone-anchored implants. A mathematical model. J Biomech. 1999;32:829–36. https://doi.org/10.1016/s0021-9290(99)00058-5.10.1016/s0021-9290(99)00058-5. ↗