Biomechanical evaluation of temporary epiphysiodesis at the femoral epiphysis using established devices from clinical practice
Source abstract
Abstract
Abstract The aim of this study is to compare biomechanical features of different devices used in clinical routine for temporary epiphysiodesis (eight-Plate® and FlexTackTM). The tested implants were divided into four different groups (eight-Plate® vs. FlexTackTM for lateral and anterior implantation) á 10 samples for testing implanted eight-Plate® vs. FlexTackTM in fresh frozen pig femora for maximum load forces (Fmax) and axial physis distance until implant failure (lmax). A servo hydraulic testing machine (858 Mini Bionix 2) was used to exert and measure reproducible forces. Statistical analyses tested for normal distribution and significant (p < 0.05) differences in primary outcome parameters. There were no significant differences between the eight-Plate® lateral group and the FlexTackTM lateral group for neither Fmax (p = 0.46) nor lmax (p = 0.65). There was a significant higher Fmax (p < 0.001) and lmax (p = 0.001) measured in the eight-Plate® group compared to the FlexTackTM group when implanted anteriorly. In anterior temporary ephiphysiodesis, eight-Plate® demonstrated superior biomechanical stability. At this stage of research, there is no clear advantage of either implant and the choice remains within the individual preference of the surgeon.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Hip disorders and treatments · Orthopaedic implants and arthroplasty · Bone fractures and treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. Oest O. [The significance of axial misalignment as a pre-osteoarthrotic deformity, and its radiological assessment]. Unfallheilkunde 1978;81:629–33.
2. Niethard M, Deja M, Rogalski M. [Correction of angular deformity of the knee in growing children by temporary hemiepiphyseodesis using the eight-plate]. Z Orthop Unfall. 2010;148:215–21. https://doi.org/10.1055/s-0029-1240732.10.1055/s-0029-1240732 ↗
3. Wiemann JMT, Tryon C, Szalay EA. Physeal stapling versus 8-plate hemiepiphysiodesis for guided correction of angular deformity about the knee. J Pediatr Orthop. 2009;29:481–5. https://doi.org/10.1097/BPO.0b013e3181aa24a8.10.1097/BPO.0b013e3181aa24a8 ↗
4. Canale ST, Christian CA. Techniques for epiphysiodesis about the knee. Clin Orthop Relat Res. 1990;81–5.10.1097/00003086-199006000-00012 ↗
5. Ogilvie JW, King K. Epiphysiodesis: two-year clinical results using a new technique. J Pediatr Orthop. 1990;10:809–11.10.1097/01241398-199011000-00021 ↗
6. Metaizeau JP, Wong-Chung J, Bertrand H, et al. Percutaneous epiphysiodesis using transphyseal screws (PETS). J Pediatr Orthop. 1998;18:363–9.
7. Cain M, Stephenson M, Umapathysivam K, et al. Effectiveness of different minimally invasive epiphysiodesis techniques in the management of pediatric leg length discrepancies: a systematic review protocol. JBI Database Syst Rev Implement Rep. 2016;14:14–24. https://doi.org/10.11124/JBISRIR-2016-002935.10.11124/JBISRIR-2016-002935 ↗
8. Blount WP, Clarke GR. Control of bone growth by epiphyseal stapling; a preliminary report. JBJS. 1949;31A:464–78.10.2106/00004623-194931030-00002 ↗
9. Stevens PM. Guided growth for angular correction: a preliminary series using a tension band plate. J Pediatr Orthop. 2007;27:253–9. https://doi.org/10.1097/BPO.0b013e31803433a1.10.1097/BPO.0b013e31803433a1 ↗
10. Kulkarni RM, Ilyas Rushnaiwala FM, Kulkarni GS, et al. Correction of coronal plane deformities around the knee using a tension band plate in children younger than 10 years. Indian J Orthop. 2015;49:208–18. https://doi.org/10.4103/0019-5413.152484.10.4103/0019-5413.152484 ↗
11. Vogt B, Horter M, Rodl R. [Special topics in pediatric orthopedics: options and limits of growth guidance]. Orthopade 2014;43:714–24. https://doi.org/10.1007/s00132-013-2223-9.10.1007/s00132-013-2223-9 ↗
12. Burghardt RD, Herzenberg JE, Standard SC, et al. Temporary hemiepiphyseal arrest using a screw and plate device to treat knee and ankle deformities in children: a preliminary report. J Child Orthop. 2008;2:187–97. https://doi.org/10.1007/s11832-008-0096-y.10.1007/s11832-008-0096-y ↗
13. Sinha R, Weigl D, Mercado E, et al. Eight-plate epiphysiodesis. Bone Jt J. 2018;100-B:1112–6. https://doi.org/10.1302/0301-620X.100B8.BJJ-2017-1206.R3.10.1302/0301-620X.100B8.BJJ-2017-1206.R3 ↗
14. Joeris A, Ramseier L, Langendorfer M, et al. Paediatric lower limb deformity correction with the Eight Plate: adverse events and correction outcomes of 126 patients from an international multicentre study. J Pediatr Orthop B. 2017;26:441–8. https://doi.org/10.1097/BPB.0000000000000397.10.1097/BPB.0000000000000397 ↗
15. Park KH, Oh CW, Kim JW, et al. Angular deformity correction by guided growth in growing children: Eight-plate versus 3.5-mm reconstruction plate. J Orthop Sci. 2017;22:919–23. https://doi.org/10.1016/j.jos.2017.06.004.10.1016/j.jos.2017.06.004 ↗
16. Vogt B, Schiedel F, Rodl R. [Guided growth in children and adolescents. Correction of leg length discrepancies and leg axis deformities]. Orthopade. 2014;43:267–84. https://doi.org/10.1007/s00132-014-2270-x.10.1007/s00132-014-2270-x ↗