Abstract

The metal-based devices may corrode, degrade, or release metal ions and fragments after being implanted in the body, exhibiting their own consequences on hosting organs/tissues. The biocompatibility of metal implants has been investigated in various studies using a number of cell types. Mesenchymal stem cells (MSCs) are more relevant cells than others for evaluating the cytocompatibility of metal-based orthopedic implants because they are essential cells for bone regeneration and a promising cell population in regenerative medicine. In this regard, stemness preservation of MSCs is a key property in both body's own repair process and success of renewing/compensating approaches. In general, MSCs adhesion, viability, and function at the cell-metal interface is directly dependent on the metal alloys composing elements, which, along with consideration of compatibility, could guarantee the success of implants. This review scrutinizes the effects of orthopedic metal materials on the biocompatibility and stemness of MSCs at metal interface. Additionally, in vivo, host responses to metal implants are investigated.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Magnesium Alloys: Properties and Applications · Tissue Engineering and Regenerative Medicine

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. Malekani J., Schmutz B., Gu Y., Schuetz M., Yarlagadda P. Orthopedic bone plates: Evolution in Structure, Implementation technique and biomaterial. GSTF Int J Eng Technol. 2012,1:135–40.10.5176/2251-3701_1.1.23 ↗
2. Saini M, Singh Y, Arora P, Arora V, Jain K. Implant biomaterials: a comprehensive review. World J Clin Cases. 2015;3:52–7.10.12998/wjcc.v3.i1.52 ↗
3. Bitar M, Friederici V, Imgrund P, Brose C, Bruinink A. In vitro bioactivity of micro metal injection moulded stainless steel with defined surface features. Eur Cell Mater. 2012;23:333–47.10.22203/eCM.v023a26 ↗
4. Navarro M, Michiardi A, Castaño O, Planell JA. Biomaterials in orthopaedics. J R Soc Interface. 2008;5:1137–58.10.1098/rsif.2008.0151 ↗
5. Zhang D, Wong CS, Wen C, Li Y. Cellular responses of osteoblast-like cells to 17 elemental metals. J Biomed Mater Res A. 2017;105:148–58.10.1002/jbm.a.35895 ↗
6. Cowley A, Woodward B. A healthy future: platinum in medical applications. Platin Met Rev. 2011;55:98–107.10.1595/147106711X566816 ↗
7. Mahmoudi Hashemi P, Borhani E, Nourbakhsh MS. A review on nanostructured stainless steel implants for biomedical application. Nanomed J. 2016;3:202–16.
8. Park Y-J, Song YH, An JH, Song HJ, Anusavice KJ. Cytocompatibility of pure metals and experimental binary titanium alloys for implant materials. J Dent. 2013;41:1251–8.10.1016/j.jdent.2013.09.003 ↗
9. Johnson I, Perchy D, Liu H. In vitro evaluation of the surface effects on magnesium-yttrium alloy degradation and mesenchymal stem cell adhesion. J Biomed Mater Res A. 2012;100:477–85.10.1002/jbm.a.33290 ↗
10. Friedenstein A, Chailakhjan R, Lalykina K. The development of fibroblast colonies in monolayer cultures of guinea‐pig bone marrow and spleen cells. Cell Prolif. 1970;3:393–403.10.1111/j.1365-2184.1970.tb00347.x ↗
11. Caplan AI. Mesenchymal stem cells. J Orthop Res. 1991;9:641–50.10.1002/jor.1100090504 ↗
12. Bianco P, Robey PG. Skeletal stem cells. Development. 2015;142:1023–7.10.1242/dev.102210 ↗
13. Petecchia L, Usai C, Vassalli M, Gavazzo P. Biophysical characterization of nanostructured TiO2 as a good substrate for hBM-MSC adhesion, growth and differentiation. Exp Cell Res. 2017;358 (2):111–9.10.1016/j.yexcr.2017.06.008 ↗
14. Shotorbani BB, Alizadeh E, Salehi R, Barzegar A. Adhesion of mesenchymal stem cells to biomimetic polymers: a review. Mater Sci Eng C. 2017;71:1192–200.10.1016/j.msec.2016.10.013 ↗
15. Niederlaender J, Walter M, Krajewski S, Schweizer E, Post M, Schille CH, et al. Cytocompatibility evaluation of different biodegradable magnesium alloys with human mesenchymal stem cells. J Mater Sci Mater Med. 2014;25:835–43.10.1007/s10856-013-5119-7 ↗
16. Aghazadeh M, Samiei M, Alizadeh E, Porkar P, Bakhtiyari M, Salehi R. Towards osteogenic bioengineering of dental pulp stem induced by sodium fluoride on hydroxyapatite based biodegradable polymeric scaffold. Fibers Polym. 2017;18:1468–77.10.1007/s12221-017-7120-0 ↗
17. Amirazad H, Dadashpour M, Zarghami N. Application of decellularized bone matrix as a bioscaffold in bone tissue engineering. J Biol Eng. 2022;16:1–18.10.1186/s13036-021-00282-5 ↗
18. Lowe, JS, PG Anderson. Chapter 13—Musculoskeletal system. In: Stevens & Lowe’s human histology. 4th ed. Philadelphia: Mosby; 2015. p. 239–62.10.1016/B978-0-7234-3502-0.00013-9 ↗
19. Nuss KMR, von Rechenberg B. Biocompatibility issues with modern implants in bone—a review for clinical orthopedics. Open Orthop J. 2008;2:66–78.10.2174/1874325000802010066 ↗
20. Marks SC, Popoff SN. Bone cell biology: the regulation of development, structure, and function in the skeleton. Dev Dyn. 1988;183:1–44.
21. Mohan BG, Suresh Babu S, Varma HK, John A. In vitro evaluation of bioactive strontium-based ceramic with rabbit adipose-derived stem cells for bone tissue regeneration. J Mater Sci Mater Med. 2013;24:2831–44.10.1007/s10856-013-5018-y ↗
22. Reyes CD, Petrie TA, Burns KL, Schwartz Z, García AJ. Biomolecular surface coating to enhance orthopaedic tissue healing and integration. Biomaterials. 2007;28:3228–35.10.1016/j.biomaterials.2007.04.003 ↗
23. Szewczenko J, Marciniak J, Kajzer W, Kajzer A. Evaluation of corrosion resistance of titanium alloys used for medical implants. Arch Metall Mater. 2016;61:695–700.10.1515/amm-2016-0118 ↗
24. Ananth H, Kundapur V, Mohammed HS, Anand M, Amarnath GS, Mankar S. A review on biomaterials in dental implantology. Int J Biomed Sci. 2015;11(3):113–20.10.59566/IJBS.2015.11113 ↗
25. Geng Z, Wang R, Zhuo X, Li Z, Huang Y, Ma L, et al. Incorporation of silver and strontium in hydroxyapatite coating on titanium surface for enhanced antibacterial and biological properties. Mater Sci Eng C Mater Biol Appl. 2017;71:852–61.10.1016/j.msec.2016.10.079 ↗
26. Christensen TJ, Samant SA, Shin AY. Making sense of metal allergy and hypersensitivity to metallic implants in relation to hand surgery. J Hand Surg Am. 2017;42:737–46.10.1016/j.jhsa.2017.06.009 ↗
27. Sun ZL, Wataha JC, Hanks CT. Effects of metal ions on osteoblast-like cell metabolism and differentiation. 1997; 34(1):29-37.10.1002/(SICI)1097-4636(199701)34:1<29::AID-JBM5>3.0.CO;2-P ↗
28. Geurtsen W. Biocompatibility of dental casting alloys. Crit Rev Oral Biol Med. 2002;13:71–84.10.1177/154411130201300108 ↗
29. Blanco JF, Sánchez-Guijo FM, Carrancio S, Muntion S, García-Briñon J, del Cañizo MC. Titanium and tantalum as mesenchymal stem cell scaffolds for spinal fusion: an in vitro comparative study. Eur Spine J. 2011;20:353–60.10.1007/s00586-011-1901-8 ↗
30. Thakral G, Thakral R, Sharma N, Seth J, Vashisht P, et al. Nanosurface—the future of implants. J Clin Diagn Res. 2014;8:7–10.
31. Amirazad H, Baradar Khoshfetrat A, Zarghami N. A dual synergistic effect of titanium and curcumin co-embedded on extracellular matrix hydrogels of decellularized bone: potential application in osteoblastic differentiation of adipose-derived mesenchymal stem cells. J Biomater Sci Polym Ed. 2023;34:372–97.10.1080/09205063.2022.2123216 ↗
32. Brown RP, Fowler BA, Fustinoni S, Costa M, Nordberg M. Toxicity of metals released from implanted medical devices. In: Handbook on the Toxicology of Metals. Academic Press, pp 127–36. Cambridge, Massachusetts, USA, 2022.10.1016/B978-0-12-823292-7.00003-6 ↗
33. Killer M, Arthur AS, Barr JD, Richling B, Cruise GM. Histomorphology of thrombus organization, neointima formation, and foreign body response in retrieved human aneurysms treated with hydrocoil devices. J Biomed Mater Res Part B Appl Biomater. 2010;94:486–92.10.1002/jbm.b.31660 ↗
34. Horiuchi T, Ito K, Hongo K, Shibuya M. Mechanical evaluation of long titanium alloy clip: comparison of cobalt alloy clip. Neurologia Med Chir. 2014;54:176–9.10.2176/nmc.oa2013-0042 ↗
35. Virtanen S. Metal release mechanisms in hip replacement. Taylor & Francis; 2006; 77:5, 695–696. Milton Park, Abingdon-on-Thames, Oxfordshire, United Kingdom.10.1080/17453670610012854 ↗
36. Caicedo M, Jacobs JJ, Reddy A, Hallab NJ. Analysis of metal ion‐induced DNA damage, apoptosis, and necrosis in human (Jurkat) T‐cells demonstrates Ni2+ and V3+ are more toxic than other metals: Al3+, Be2+, Co2+, Cr3+, Cu2+, Fe3+, Mo5+, Nb5+, Zr2+. J Biomed Mater Res Part A. 2008;86:905–13.10.1002/jbm.a.31789 ↗
37. Lalmohamed A, MacGregor AJ, de Vries F, Leufkens HG, van Staa TP. Patterns of risk of cancer in patients with metal-on-metal hip replacements versus other bearing surface types: a record linkage study between a prospective joint registry and general practice electronic health records in England. PLoS ONE. 2013;8:e65891.10.1371/journal.pone.0065891 ↗
38. Tower SS. Arthroprosthetic cobaltism: neurological and cardiac manifestations in two patients with metal-on-metal arthroplasty: a case report. JBJS. 2010;92:2847–51.10.2106/JBJS.J.00125 ↗
39. Caimi S, Petrucci F, Cristaudo A, Bordignon V. SF-ICP-MS analysis of palladium in fluids of patients sensitized to metal-based dental restorations. Open Chem Biomed Methods J. 2009;2:48–54.10.2174/1875038900902020048 ↗
40. Buntz B. Three generations of biomaterials. 2011; Available from: https://www.mddionline.com/three-generations-biomaterials.
41. Vojtěch D, Kubásek J, Serák J, Novák P. Mechanical and corrosion properties of newly developed biodegradable Zn-based alloys for bone fixation. Acta Biomater. 2011;7:3515–22.10.1016/j.actbio.2011.05.008 ↗
42. Gu X, Zheng Y, Zhong S, Xi T, Wang J, Wang W. Corrosion of, and cellular responses to Mg–Zn–Ca bulk metallic glasses. Biomaterials. 2010;31:1093–103.10.1016/j.biomaterials.2009.11.015 ↗
43. Zhang S, Zhang X, Zhao C, Li J, Song Y, Xie C, et al. Research on an Mg–Zn alloy as a degradable biomaterial. Acta biomater. 2010;6:626–40.10.1016/j.actbio.2009.06.028 ↗
44. Hänzi AC, Gerber I, Schinhammer M, Löffler JF, Uggowitzer PJ. On the in vitro and in vivo degradation performance and biological response of new biodegradable Mg–Y–Zn alloys. Acta Biomater. 2010;6:1824–33.10.1016/j.actbio.2009.10.008 ↗
45. Yang L, Huang Y, Peng Q, Feyerabend F, Kainer KU, Willumeit R, et al. Mechanical and corrosion properties of binary Mg–Dy alloys for medical applications. Mater Sci Eng B. 2011;176:1827–34.10.1016/j.mseb.2011.02.025 ↗
46. Balla VK, Bose S, Davies NM, Bandyopadhyay A. Tantalum—a bioactive metal for implants. JOM. 2010;62:61–64.10.1007/s11837-010-0110-y ↗
47. Mikulewicz M, Chojnacka K. Cytocompatibility of medical biomaterials containing nickel by osteoblasts: a systematic literature review. Biol Trace Elem Res. 2011;142:865–89.10.1007/s12011-010-8798-7 ↗
48. Ghaffari M, Moztarzadeh F, Sepahvandi A, Mozafari M, Faghihi S. How bone marrow-derived human mesenchymal stem cells respond to poorly crystalline apatite coated orthopedic and dental titanium implants. Ceram Int. 2013;39:7793–802.10.1016/j.ceramint.2013.03.039 ↗
49. Liu J, Zhang W, Shi H, Yang K, Wang G, Wang P, et al. In situ plasma fabrication of ceramic-like structure on polymeric implant with enhanced surface hardness, cytocompatibility and antibacterial capability. J Biomed Mater Res A. 2016;104:1102–12.10.1002/jbm.a.35652 ↗
50. Zujur D, Moret J, Rodriguez D, Cruz L, Lira J, Gil L, et al. A novel photocrosslinkable and cytocompatible chitosan coating for Ti6Al4V surfaces. J Appl Biomater Funct Mater. 2015;13:e210–9.
51. Leem YH, Lee KS, Kim JH, Seok HK, Chang JS, Lee DH. Magnesium ions facilitate integrin alpha 2- and alpha 3-mediated proliferation and enhance alkaline phosphatase expression and activity in hBMSCs. J Tissue Eng Regen Med. 2016;10:E527–36.10.1002/term.1861 ↗
52. Ma WH, Liu YJ, Wang W, Zhang YZ. Improved biological performance of magnesium by micro-arc oxidation. Braz J Med Biol Res. 2015;48:214–25.10.1590/1414-431x20144171 ↗
53. Pompa L, Rahman ZU, Munoz E, Haider W. Surface characterization and cytotoxicity response of biodegradable magnesium alloys. Mater Sci Eng C Mater Biol Appl. 2015;49:761–8.10.1016/j.msec.2015.01.017 ↗
54. Wang B, Huang P, Ou C, Li K, Yan B, Lu W. In vitro corrosion and cytocompatibility of ZK60 magnesium alloy coated with hydroxyapatite by a simple chemical conversion process for orthopedic applications. Int J Mol Sci. 2013;14:23614–28.10.3390/ijms141223614 ↗
55. Weizbauer A, Seitz JM, Werle P, Hegermann J, Willbold E, Eifler R, et al. Novel magnesium alloy Mg-2La caused no cytotoxic effects on cells in physiological conditions. Mater Sci Eng C Mater Biol Appl. 2014;41:267–73.10.1016/j.msec.2014.04.063 ↗
56. Zhang L, Pei J, Wang H, Shi Y, Niu J, Yuan F, et al. Facile preparation of poly(lactic acid)/brushite bilayer coating on biodegradable magnesium alloys with multiple functionalities for orthopedic application. ACS Appl Mater Interfaces. 2017;9:9437–48.10.1021/acsami.7b00209 ↗
57. Salahinejad E, Hadianfard MJ, Macdonald DD, Sharifi Asl S, Mozafari M, Walker KJ, et al. Surface modification of stainless steel orthopedic implants by sol-gel ZrTiO4 and ZrTiO4-PMMA coatings. J Biomed Nanotechnol. 2013;9:1327–35.10.1166/jbn.2013.1619 ↗
58. Salahinejad E, Hadianfard MJ, Macdonald DD, Sharifi-Asl S, Mozafari M, Walker KJ, et al. In vitro electrochemical corrosion and cell viability studies on nickel-free stainless steel orthopedic implants. PLoS ONE. 2013;8:e61633.10.1371/journal.pone.0061633 ↗
59. Clem WC, Chowdhury S, Catledge SA, Weimer JJ, Shaikh FM, Hennessy KM, et al. Mesenchymal stem cell interaction with ultra-smooth nanostructured diamond for wear-resistant orthopaedic implants. Biomaterials. 2008;29:3461–8.10.1016/j.biomaterials.2008.04.045 ↗
60. Martino S, D'Angelo F, Armentano I, Kenny JM, Orlacchio A. Stem cell-biomaterial interactions for regenerative medicine. Biotechnol Adv. 2012;30:338–51.10.1016/j.biotechadv.2011.06.015 ↗
61. Saei Arezoumand K, Alizadeh E, Pilehvar-Soltanahmadi Y, Esmaeillou M, Zarghami N. An overview on different strategies for the stemness maintenance of MSCs. Artif Cells Nano Med Biotechnol. 2017;45(7):1255–71.10.1080/21691401.2016.1246452 ↗
62. Sohn EJ, Moon HJ, Lim JK, Kim DS, Kim JH. Regulation of the protein stability and transcriptional activity of OCT4 in stem cells. Adv Biol Regul. 2021;79:100777.10.1016/j.jbior.2020.100777 ↗
63. Takahashi K, Yamanaka S. Induction of pluripotent stem cells from mouse embryonic and adult fibroblast cultures by defined factors. Cell. 2006;126:663–76.10.1016/j.cell.2006.07.024 ↗
64. Yao Y, Lu Y, Chen WC, Jiang Y, Cheng T, Ma Y, et al. Cobalt and nickel stabilize stem cell transcription factor OCT4 through modulating its sumoylation and ubiquitination. PLoS ONE. 2014;9:e86620.10.1371/journal.pone.0086620 ↗
65. Sarikhani M, Vaghefi Moghaddam S, Firouzamandi M, Hejazy M, Rahimi B, Moeini H, et al. Harnessing rat derived model cells to assess the toxicity of TiO2 nanoparticles. J Mater Sci Mater Med. 2022;33:41.10.1007/s10856-022-06662-7 ↗
66. Nguyen TY, Liew CG, Liu H. An in vitro mechanism study on the proliferation and pluripotency of human embryonic stems cells in response to magnesium degradation. PLoS ONE. 2013;8:e76547.10.1371/journal.pone.0076547 ↗
67. Wang Q, Xu X, Li J, Liu J, Gu H, Zhang R, et al. Lithium, an anti-psychotic drug, greatly enhances the generation of induced pluripotent stem cells. Cell Res. 2011;21:1424–35.10.1038/cr.2011.108 ↗
68. Jin Y, Xu L, Hu X, Liao S, Pathak JL, Liu J. Lithium chloride enhances bone regeneration and implant osseointegration in osteoporotic conditions. J Bone Miner Metab. 2017; 35 (5);497–503.10.1007/s00774-016-0783-6 ↗
69. Li WJ, Yang CL, Chow KC, Kuo TW. Hexavalent chromium induces expression of mesenchymal and stem cell markers in renal epithelial cells. Mol Carcinog. 2016;55:182–92.10.1002/mc.22268 ↗
70. Lin TM, Tsai JL, Lin SD, Lai CS, Chang CC. Accelerated growth and prolonged lifespan of adipose tissue-derived human mesenchymal stem cells in a medium using reduced calcium and antioxidants. Stem Cells Dev. 2005;14:92–102.10.1089/scd.2005.14.92 ↗
71. Thomas P, Gollwitzer H, Maier S, Rueff F. Osteosynthesis associated contact dermatitis with unusual perpetuation of hyperreactivity in a nickel allergic patient. Contact Dermat. 2006;54:222–5.10.1111/j.0105-1873.2006.0775j.x ↗
72. Niki Y, Matsumoto H, Otani T, Yatabe T, Kondo M, Yoshimine F, et al. Screening for symptomatic metal sensitivity: a prospective study of 92 patients undergoing total knee arthroplasty. Biomaterials. 2005;26:1019–26.10.1016/j.biomaterials.2004.03.038 ↗
73. Harloff T, Hönle W, Holzwarth U, Bader R, Thomas P, Schuh A. Titanium allergy or not?” Impurity” of titanium implant materials. Health. 2010;2:306–10.10.4236/health.2010.24045 ↗
74. Barile FA. Clinical toxicology: principles and mechanisms. CRC Press; 2010. Boca Raton, Fla, FL 33487, USA.
75. Willert H-G, Buchhorn GH, Fayyazi A, Flury R, Windler M, Köster G, et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints: a clinical and histomorphological study. JBJS. 2005;87:28–36.10.2106/00004623-200501000-00006 ↗
76. Basketter DA, Angelini G, Ingber A, Kern PS, Menné T. Nickel, chromium and cobalt in consumer products: revisiting safe levels in the new millennium. Contact Dermat. 2003;49:1–7.10.1111/j.0105-1873.2003.00149.x ↗
77. Pizzutelli S. Systemic nickel hypersensitivity and diet: myth or reality?. Eur Ann Allergy Clin Immunol. 2011;43:5–18.
78. Linder L, Lundskog J. Incorporation of stainless steel, titanium and Vitallium in bone. Injury. 1975;6:277–85.10.1016/0020-1383(75)90174-6 ↗
79. Carossino AM, Carulli C, Ciuffi S, Carossino R, Zappoli Thyrion GD, Zonefrati R, et al. Hypersensitivity reactions to metal implants: laboratory options. BMC Musculoskelet Disord. 2016;17:486.10.1186/s12891-016-1342-y ↗
80. Summer B, Fink U, Zeller R, Rueff F, Maier S, Roider G, et al. Patch test reactivity to a cobalt–chromium–molybdenum alloy and stainless steel in metal‐allergic patients in correlation to the metal ion release. Contact Dermat. 2007;57:35–9.10.1111/j.1600-0536.2007.01139.x ↗
81. Hase A, Mishina H, Wada M. Correlation between features of acoustic emission signals and mechanical wear mechanisms. Wear. 2012;292:144–50.10.1016/j.wear.2012.05.019 ↗
82. Staiger MP, Pietak AM, Huadmai J, Dias G. Magnesium and its alloys as orthopedic biomaterials: a review. Biomaterials. 2006;27:1728–34.10.1016/j.biomaterials.2005.10.003 ↗
83. Virtanen S. Biodegradable Mg and Mg alloys: corrosion and biocompatibility. Mater Sci Eng: B. 2011;176:1600–8.10.1016/j.mseb.2011.05.028 ↗
84. Merritt K, Brown SA. Distribution of cobalt chromium wear and corrosion products and biologic reactions. Clin Orthop Relat Res. 1996;329:S233–43.10.1097/00003086-199608001-00020 ↗
85. Heath J, Freeman M, Swanson S. Carcinogenic properties of wear particles from prostheses made in cobalt-chromium alloy. Lancet. 1971;297:564–6.10.1016/S0140-6736(71)91162-7 ↗
86. Urbano AM, Rodrigues CF, Alpoim MC. Hexavalent chromium exposure, genomic instability and lung cancer. Gene Ther Mol Biol. 2008;12:219–38.
87. Demehri S, Cunningham TJ, Hurst EA, Schaffer A, Sheinbein DM, Yokoyama WM. Chronic allergic contact dermatitis promotes skin cancer. J Clin Investig. 2014;124:5037–41.10.1172/JCI77843 ↗
88. Costa M, Klein CB. Toxicity and carcinogenicity of chromium compounds in humans. Crit Rev Toxicol. 2006;36:155–63.10.1080/10408440500534032 ↗
89. Albers CE, Hofstetter W, Siebenrock KA, Landmann R, Klenke FM. In vitro cytotoxicity of silver nanoparticles on osteoblasts and osteoclasts at antibacterial concentrations. Nanotoxicology. 2013;7:30–6.10.3109/17435390.2011.626538 ↗
90. Berglund IS, Brar HS, Dolgova N, Acharya AP, Keselowsky BG, Sarntinoranont M, et al. Synthesis and characterization of Mg-Ca-Sr alloys for biodegradable orthopedic implant applications. J Biomed Mater Res B Appl Biomater. 2012;100:1524–34.10.1002/jbm.b.32721 ↗
91. Bosetti M, Massè A, Tobin E, Cannas M. Silver coated materials for external fixation devices: in vitro biocompatibility and genotoxicity. Biomaterials. 2002;23:887–92.10.1016/S0142-9612(01)00198-3 ↗
92. Chen M, Hein S, Le DQ, Feng W, Foss M, Kjems J, et al. Free radicals generated by tantalum implants antagonize the cytotoxic effect of doxorubicin. Int J Pharm. 2013;448:214–20.10.1016/j.ijpharm.2013.03.041 ↗
93. Ciapetti G, Roda P, Landi L, Facchini A, Pizzoferrato A. In vitro methods to evaluate metal-cell interactions. Int J Artif Organs. 1992;15:62–6.10.1177/039139889201500111 ↗
94. Divya Rani VV, Manzoor K, Menon D, Selvamurugan N, Nair SV. The design of novel nanostructures on titanium by solution chemistry for an improved osteoblast response. Nanotechnology. 2009;20:195101.10.1088/0957-4484/20/19/195101 ↗
95. Eto S, Miyamoto H, Shobuike T, Noda I, Akiyama T, Tsukamoto M, et al. Silver oxide-containing hydroxyapatite coating supports osteoblast function and enhances implant anchorage strength in rat femur. J Orthop Res. 2015;33:1391–7.10.1002/jor.22903 ↗
96. Fazel Anvari-Yazdi A, Tahermanesh K, Hadavi SM, Talaei-Khozani T, Razmkhah M, Abed SM, et al. Cytotoxicity assessment of adipose-derived mesenchymal stem cells on synthesized biodegradable Mg-Zn-Ca alloys. Mater Sci Eng C Mater Biol Appl. 2016;69:584–97.10.1016/j.msec.2016.07.016 ↗
97. Feng Y, Cao C, Li BE, Liu XY, Dong YQ. Primary study on the antibacterial property of silver-loaded nano-titania coatings. Zhonghua Yi Xue Za Zhi. 2008;88:2077–80.
98. Gu XN, Xie XH, Li N, Zheng YF, Qin L. In vitro and in vivo studies on a Mg-Sr binary alloy system developed as a new kind of biodegradable metal. Acta Biomater. 2012;8:2360–74.10.1016/j.actbio.2012.02.018 ↗
99. Guan RG, Johnson I, Cui T, Zhao T, Zhao ZY, Li X, et al. Electrodeposition of hydroxyapatite coating on Mg-4.0Zn-1.0Ca-0.6Zr alloy and in vitro evaluation of degradation, hemolysis, and cytotoxicity. J Biomed Mater Res A. 2012;100:999–1015.10.1002/jbm.a.34042 ↗
100. Han P, Cheng P, Zhang S, Zhao C, Ni J, Zhang Y, et al. In vitro and in vivo studies on the degradation of high-purity Mg (99.99wt.%) screw with femoral intracondylar fractured rabbit model. Biomaterials. 2015;64:57–69.10.1016/j.biomaterials.2015.06.031 ↗