journal article·2002-11

Creep behavior comparison of CMW1 and palacos R-40 clinical bone cements

C. Liu, S. M. Green, N. D. Watkins, P. J. Gregg, A. W. McCaskie

Publisher page

Abstract

The restrained dynamic creep behaviors of two clinical bone cements, Palacos R-40 and CMW1 have been investigated at room temperature and body temperature. It was found that the two cements demonstrated significantly different creep deformations, with Palacos R-40 bone cement demonstrating higher creep strain than CMW1 bone cement at each loading cycle. For both cements, two stages of creep were identified with a higher creep rate during early cycling followed by a steady-state creep rate. The test temperature had a strong effect on the creep performance of the bone cements with higher creep rate observed at body temperature. The relationship between creep deformation and loading cycles can be expressed by single logarithmic model. The SEM examinations revealed that CMW1 bone cement is more sensitive to defects within the specimen especially to the defects at the edges of the specimen than Palacos R-40 bone cement. However, in the absence of micro-cracks or defects within the inner surface layer, the dynamic loading (at less than 10.6 MPa) is unlikely to produce micro-cracks in the CMW1 bone cement. The different behaviors between the two bone cements may be attributed to differences in chemical compositions and molecular weight distributions.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. E. Ebramzadeh, M. Minaarghi and I. C. Clarke, “Loosening of Well Cemented Total Hip Femoral Prosthesis Due to Creep of the Cement”, (ASTM Special Technical Publication, 1985).10.1520/STP33265S ↗
2. Orthopaedic Hospital Los Angeles, “Total Hip Arthroplasty: A Manual for Prospective Patients” (2000).
3. A. Faulkner, L. G. Kennedy, K. Baxter, J. Donovan, M. Wilkinson and G. Bevan, Health Tech. Assess. 2 (1998) 1.10.3310/hta2060 ↗
4. R. T. Muller, I. Heger and M. Oldenbury, Arch. Orthop. Trauma Surg. 116 (1997) 41.10.1007/BF00434099 ↗
5. B. M. Lwak, O. K. Lim and Y. Y. Kim, Intern. Orthop. 2 (1979) 315.
6. Z. Lu and H. Mckellop, J. Biomed. Mat. Res. 34 (1997) 221.10.1002/(SICI)1097-4636(199702)34:2<221::AID-JBM11>3.0.CO;2-L ↗
7. S. Saha and S. Pal, ibid. 18 (1984) 435.10.1002/jbm.820180411 ↗
8. B. Vazquez, S. Deb and W. Bonfield, J. Mat. Sci.: Mat. Med. 8 (1997) 455.
9. E. Lautens and G. W. Marshall, J. Biomed. Mat. Res. 10 (1976) 837.10.1002/jbm.820100603 ↗
11. J. R. De Wijn, T. J. Sloff and F. C. M. Driessens, Acta. Orthop. Scand. 46 (1975) 38.10.3109/17453677508989190 ↗
12. A. J. C. Lee, R. D. Perkins and R. S. M. Ling, in “Implant Bone Interface”, edited by J. Older (Springer-Verlag, London, 1990) p. 85.10.1007/978-1-4471-1811-4_12 ↗
13. N. Verdonschot and R. Huiskes, J. Bone Joint Surg. 79-B (1997) 665.10.1302/0301-620X.79B4.0790665 ↗
14. J. L. Fowler, G. A. Gie and R. S. M. Ling, Orthop. Clin. North Am., 19 (1988) 477.
15. W. H. Harris, Clin. Orthop. Rel. Res. 274 (1992) 120.
16. D. J. Chwirut, J. Biomed. Mat. Res. 18 (1984) 25.10.1002/jbm.820180105 ↗
17. T. L. Norman, V. Kish and J. D. Blaha et al., J. Biomed. Mat. Res. 29 (1995) 495.10.1002/jbm.820290409 ↗
18. N. Verdonschot and R. Huiskes, J. Appl. Biomat. 5 (1994) 235.10.1002/jab.770050309 ↗
19. C. Z. Liu, S. M. Green, N. D. Watkins, P. J. Gregg and A. W. Mccaskie, Proc. Instn. Mech. Engrs: Part H 215 (2001) 359.10.1243/0954411011535948 ↗
20. E. J. Harper, W. Bonfield J. Biomed. Mat. Res. (Appl. Biomat.) 53 (2000) 605.10.1002/1097-4636(200009)53:5<605::AID-JBM22>3.0.CO;2-5 ↗
21. S. L. Smith, I. C. Burgess and A. Unsworth, Proc. Instn. Mech. Engrs: Part H 213 (1999) 469.10.1243/0954411991535077 ↗
22. J. C. Arnold and N. P. Venditti, J. Mat. Sci.: Mat. Med. 12 (2001) 707.
23. S. A. Visser, R. Hergenrother and S. L. Cooper, in “Biomaterials Science”, edited by B. D. Ratner (Academic Press, San Diego, California, USA, 1996) p. 60.
24. G. Deane, W. Ege and W. Elson, in “Palacos with Gentamicin: A Practical Guide” (Schering-Plough Ltd., Mildenhall, Suffolk, 1999).