journal article·2001-03

Laser confocal microscopic study of pH profiles of synthetic absorbable fibers upon in vitro hydrolytic degradation

M. A. Slivka, C. C. Chu, Y. L. Zhang

Publisher page

Abstract

The objective of this study was to develop a new and non-destructive technique to measure the interior pH of synthetic absorbable biomaterials. Such a measurement would provide the required experimental evidence for validating the postulated theory that the accumulation of acidic hydrolytic degradation products within the interior of aliphatic polyesters is responsible for the observed accelerated degradation of this class of absorbable biomaterials. This new technique used a laser scanning confocal microscope coupled with pH sensitive fluorescent dyes like Texas Red sulfonyl chloride. The capability of optical thin sectioning of a laser confocal microscope would permit a non-destructive examination of the interior of biomaterials. Poly-p-dioxanone suture fibers (PDSII) of size 2/0 were used as the model compound for this new technique. The pH values of the unhydrolyzed and partially hydrolyzed PDSII fibers were found to decrease with increasing depth from the fiber surface and reached as low as about 3.5 at 70 microm depth. The largest depth that an interior pH could be measured within absorbable biomaterials was determined by the opacity of the biomaterials, i.e. a higher depth for a less opaque material. The observed interior pH profiles were correlated to the unique morphologic structure of PDSII fibers.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · biodegradable polymer synthesis and properties · Surgical Sutures and Adhesives

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. A. U. DANIELS, M. S. TAYLOR, K. P. ANDRIANO and J. HELLER, Trans. 38th Ann. Mtg. Orthop. Res. Soc. 17 (1992) 88.
2. M. S. TAYLOR, A. U. DANIELS, K. P. ANDRIANO and J. HELLER, J. Appl. Biomater. 5 (1994) 151–157.10.1002/jab.770050208 ↗
3. J. EITENMÜLLER, K. L. GERLACH, T. SCHMICKAL, and G. MUHR, Die Versorgung von Sprunggelenksfrakturen unter Verwendung von Platten und Schrauben aus resorbierbarem Polymer material, presented at Jahrestagung der Deutschen Gesellschaft für Unfallheilkunde, Berlin, November 1989.10.1007/978-3-642-75920-8_164 ↗
4. H. WINET and J. O. HOLLINGER, J. Biomed. Mater. Res. 27 (1993) 667.10.1002/jbm.820270514 ↗
5. O. BOSTMAN, E. HIRVENSALO et al., Intern. Orthop. (SICOT) 14 (1990) 1.10.1007/BF00183354 ↗
6. G. O. HOFMANN, T. METZGER et al., Biodegradable implants in traumatology – A review of the state of the art, XVIII SICOT Conference, Montreal, September 7, 1990, p. 190.
7. A. S. LITSKY, J. Appl. Biomater. 4 (1993) 109–111.10.1002/jab.770040116 ↗
8. L. CLAES, in “Clinical Implant Materials”, edited by G. HEIMKE, U. SOLTESZ and A. J. C. LEE, Elsevier, Amsterdam, pp. 161–167.
9. L. CLAES, in “Biodegradable Implants in Orthopaedic Surgery” edited by G. O. Hofmann, Kommunikation, Berlin, pp. 83–93.
10. K. E. REHM, H. J. HELLING et al., in Jahrbuch der Chir, edited by H. Bunte, T. Junginger and A. Holzgreve edited by Biermann, Zulpich, 1989, pp. 223–32.
11. G. O. HOFMANN, Clin. Mater. 10 (1992) 75.10.1016/0267-6605(92)90088-B ↗
12. J. SUGANUMA, and H. ALEXANDER, J. Appl. Biomater. 4(1) (1993) 13.10.1002/jab.770040103 ↗
13. C. C. CHU, Polymer 26 (1985) 591–594.10.1016/0032-3861(85)90160-0 ↗
14. M. HANTHAMRONGWIT, R. WILKINSON, C. OSBORNE, W. H. REID, and M. H. GRANT, J. Biomed. Mater. Res. 30 (1996) 331–339.10.1002/(SICI)1097-4636(199603)30:3<331::AID-JBM7>3.0.CO;2-R ↗
15. M. A. SLIVKA, and C. C. CHU, J. Biomed. Mater. Res. 37(3) (1997) 353–362.10.1002/(SICI)1097-4636(19971205)37:3<353::AID-JBM6>3.0.CO;2-K ↗
16. M. VERT, S. M. LI, G. SPENLEHAUER and P. GUERIN, J. Mater. Sci. Mater. Med. 3 (1992) 423–446.10.1007/BF00701240 ↗
17. P. MAINIL-VARLET, R. CURTIS and S. GOGOLEWSKI, J. Biomed. Mater. Res. 36(3) (1997) 360–380.10.1002/(SICI)1097-4636(19970905)36:3<360::AID-JBM11>3.0.CO;2-I ↗
18. I. H. LOH, H. L. LIN and C. C. CHU, J. Appl. Biomater. 3(2) (1992) 131–146.10.1002/jab.770030209 ↗
19. E. BROYER, U. S. Patent 5,294,395, Ethicon, Inc., 1994.
20. C. C. CHU, J. A. VON FRAUNHOFER and H. P. GREISLER, “Wound Closure Biomaterials and Devices”, (CRC Press, Boca Raton, FL, 1997) p. 147.
21. H. L. LIN, C. C. CHU and D. GRUBB, J. Biomed. Mater. Res. 27(2) (1993) 153.10.1002/jbm.820270204 ↗
22. L. E. SANZ, J. A. PATTERSON, R. KAMATH, G. WILLETT, S. W. AHMED and A. B. BUTTERFIELD, Obstet. Gynecol. 71 (1988) 418.
23. J. A. RAY, N. DODDI, D. REGULA, J. A. WILLIAMS, and A. MELVEGER, Surg. Gynecol. Obstet. 153 (1981) 497.
24. R. B. BOURNE, H. BITAR, P. R. ANDREAE, et al., Can. J. Surg. 31 (1988) 43.
25. L. G. FRIBERG, G. W. MELLGREN, B. D. ERIKSSON, et al., Scand. J. Thorac. Cardiovasc. Surg. 21 (1987) 9.10.3109/14017438709116912 ↗
26. S. A. METZ, N. CHEGINI, and B. J. MASTERSON, Biomaterials 11 (1990) 41.10.1016/0142-9612(90)90050-Z ↗