journal article·2017-09

Analysis of the hemostatic potential of modern topical sealants on arterial and venous anastomoses: an experimental porcine study

Hamidreza Fonouni, Arash Kashfi, Ali Majlesara, Oliver Stahlheber, Lukas Konstantinidis, Thomas W. Kraus, Arianeb Mehrabi, Hani Oweira

Publisher page

Abstract

One of the widely accepted adjunctive agents in the variety of surgical modalities are sealants. Our study aim was to compare four commonly used modern sealants in a standardized experimental setting to assess their feasibility, and hemostatic efficacy in vascular anastomosis. Forty landrace pigs (weight: 24.7 ± 3.8 kg) were randomized into the control (n = 8) and four sealant groups; TachoSil® (n = 8), Tissucol Duo® (n = 8), Coseal® (n = 8), and FloSeal® (n = 8). After doing a portal vein end-to-end anastomosis as well as stitches of aortic incision, the sealants were applied on anastomotic site. The control group was left intact. In portal vein anastomosis, the sealants led to a complete hemostasis significantly better than control group. The mean of blood loss was also significantly reduced. In successful subgroups, there was a difference in the mean-time to reach complete hemostasis ranging from 15 s in Coseal® to 76 s in FloSeal® group (p < 0.05). In aortotomy experiments, except Tissucol Due®, which had insufficient hemostasis, other sealants led to a complete hemostasis. The mean blood loss was significantly reduced in sealants groups as well. The four sealants are effective in reducing the suture-hole bleeding in portal vein anastomosis. However, the hemostatic potential is heterogeneous among sealants. This means that "one-size-fits-all" approach is not appropriate for application of sealants in diversity of vascular surgery and it should be based on the type and the severity of injury and the structure of tissue. Comparison of hemostasis efficacy of four modern sealants (TachoSil®, Tissucol Duo®, Coseal®, and FloSeal®) in vascular anastomosis in porcine model. The figures below show the total blood loss (g) in the control and sealant groups after aortotomy (left) and portal vein anastomosis (right). The mean of blood loss decreased significantly by the usage of sealants in both experiment groups as compared to control group (*: p < 0.05; sealant groups vs. control group). 1. The right column shows the mean of blood loss (g) in all experiments in each group. 2. The middle column presents the subgroup with unsuccessful hemostasis at the end of observation time (Tmax = 20 sec. for aortotmy and 300 sec. for portal vein anastomosis). 3. The left column shows mean of total blood loss in subgroups with successful hemostasis during observation time (20 sec for aortotomy and 300 sec for portal vein).
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Hemostasis and retained surgical items · Surgical Sutures and Adhesives · Reconstructive Surgery and Microvascular Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Rogers AC, Turley LP, Cross KS, McMonagle MP. Meta-analysis of the use of surgical sealants for suture-hole bleeding in arterial anastomoses. Br J Surg. 2016;103(13):1758–67. doi: 10.1002/bjs.10308 .10.1002/bjs.10308 ↗
2. Reuthebuch O, Lachat ML, Vogt P, Schurr U, Turina M. FloSeal: a new hemostyptic agent in peripheral vascular surgery. Vasa. 2000;29(3):204–6. doi: 10.1024/0301-1526.29.3.204 .10.1024/0301-1526.29.3.204 ↗
3. Zeebregts CJ, Heijmen RH, van den Dungen JJ, van Schilfgaarde R. Non-suture methods of vascular anastomosis. Br J Surg. 2003;90(3):261–71. doi: 10.1002/bjs.4063 .10.1002/bjs.4063 ↗
4. Padubidri AN, Browne E. A new method of applying fibrin glue at the microvascular anastomotic site: the “paintbrush” technique. Microsurgery. 1996;17(8):428–30. doi:10.1002/(SICI)1098-2752(1996)17:8<428::AID-MICR2>3.0.CO;2-A.10.1002/(SICI)1098-2752(1996)17:8<428::AID-MICR2>3.0.CO;2-A ↗
5. Burnouf-Radosevich M, Burnouf T, Huart JJ. Biochemical and physical properties of a solvent-detergent-treated fibrin glue. Vox Sang. 1990;58(2):77–84.10.1111/j.1423-0410.1990.tb02066.x ↗
6. Pusateri AE, Holcomb JB, Kheirabadi BS, Alam HB, Wade CE, Ryan KL. Making sense of the preclinical literature on advanced hemostatic products. J Trauma. 2006;60(3):674–82. doi: 10.1097/01.ta.0000196672.47783.fd .10.1097/01.ta.0000196672.47783.fd ↗
7. Spotnitz WD. Commercial fibrin sealants in surgical care. Am J Surg. 2001;182(2 Suppl):8S–14S.10.1016/S0002-9610(01)00771-1 ↗
8. Spotnitz WD, Prabhu R. Fibrin sealant tissue adhesive--review and update. J Long Term Eff Med Implants. 2005;15(3):245–70.10.1615/JLongTermEffMedImplants.v15.i3.20 ↗
9. MacGillivray TE. Fibrin sealants and glues. J Card Surg. 2003;18(6):480–5.10.1046/j.0886-0440.2003.02073.x ↗
10. Kheirabadi BS, Pearson R, Tuthill D, Rudnicka K, Holcomb JB, Drohan W, et al. Comparative study of the hemostatic efficacy of a new human fibrin sealant: is an antifibrinolytic agent necessary? J Trauma. 2002;52(6):1107–15.10.1097/00005373-200206000-00014 ↗
11. Wan L, Li D, Wu Q. Perivenous application of fibrin glue as external support enhanced adventitial adenovirus transfection in rabbit model. J Surg Res. 2006;135(2):312–6. doi: 10.1016/j.jss.2006.02.056 .10.1016/j.jss.2006.02.056 ↗
12. Dickneite G, Metzner H, Nicolay U. Prevention of suture hole bleeding using fibrin sealant: benefits of factor XIII. J Surg Res. 2000;93(2):201–5. doi: 10.1006/jsre.2000.5985 .10.1006/jsre.2000.5985 ↗
13. Unlu Y, Vural U, Kocak H, Ceviz M, Becit N, Akbulut O. Comparison of the topical haemostatic agents for the prevention of suture hole bleeding. An Experimental Study. Eur J Vasc Endovasc Surg. 2002;23(5):441–4. doi: 10.1053/ejvs.2002.1619 .10.1053/ejvs.2002.1619 ↗
14. Kheirabadi BS, Pearson R, Rudnicka K, Somwaru L, MacPhee M, Drohan W, et al. Development of an animal model for assessment of the hemostatic efficacy of fibrin sealant in vascular surgery. J Surg Res. 2001;100(1):84–92. doi: 10.1006/jsre.2001.6226 .10.1006/jsre.2001.6226 ↗
15. Kheirabadi BS, Field-Ridley A, Pearson R, MacPhee M, Drohan W, Tuthill D. Comparative study of the efficacy of the common topical hemostatic agents with fibrin sealant in a rabbit aortic anastomosis model. J Surg Res. 2002;106(1):99–107.10.1006/jsre.2002.6426 ↗
16. Saitoh S, Nakatsuchi Y. Long-term results of vein grafts interposed in arterial defects using the telescoping anastomotic technique and fibrin glue. J Hand Surg Br. 1996;21(1):47–52.10.1016/S0266-7681(96)80011-8 ↗
17. Bowen CV, Leach DH, Crosby NL, Reynolds R. Microvascular anastomoses. A comparative study of fibrinogen adhesive and interrupted suture techniques. Plast Reconstr Surg. 1996;97(4):792–800.10.1097/00006534-199604000-00016 ↗
18. Gupta N, Chetter I, Hayes P, AH OY, Moneta GL, Shenoy S, et al. Randomized trial of a dry-powder, fibrin sealant in vascular procedures. J Vasc Surg. 2015;62(5):1288–95. doi: 10.1016/j.jvs.2015.05.038 .10.1016/j.jvs.2015.05.038 ↗
19. Lisy M, Kahlil M, Stock UA, Wildhirt SM. Fibrin sealant patch for repair of acute type a aortic dissection. J Card Surg. 2013;28(6):736–41. doi: 10.1111/jocs.12208 .10.1111/jocs.12208 ↗
20. Saha SP, Muluk S, Schenk W 3rd, Dennis JW, Ploder B, Grigorian A, et al. A prospective randomized study comparing fibrin sealant to manual compression for the treatment of anastomotic suture-hole bleeding in expanded polytetrafluoroethylene grafts. J Vasc Surg. 2012;56(1):134–41. doi: 10.1016/j.jvs.2012.01.009 .10.1016/j.jvs.2012.01.009 ↗
21. Natour E, Suedkamp M, Dapunt OE. Assessment of the effect on blood loss and transfusion requirements when adding a polyethylene glycol sealant to the anastomotic closure of aortic procedures: a case-control analysis of 102 patients undergoing Bentall procedures. J Cardiothorac Surg. 2012;7:105 doi: 10.1186/1749-8090-7-105 .10.1186/1749-8090-7-105 ↗
22. Seguin JR, Picard E, Frapier JM, Chaptal PA. Aortic valve repair with fibrin glue for type A acute aortic dissection. Ann Thorac Surg. 1994;58(2):304–6.10.1016/0003-4975(94)92197-0 ↗
23. Kram HB, Nugent P, Reuben BI, Shoemaker WC. Fibrin glue sealing of polytetrafluoroethylene vascular graft anastomoses: comparison with oxidized cellulose. J Vasc Surg. 1988;8(5):563–8.10.1016/0741-5214(88)90306-0 ↗
24. Milne AA, Murphy WG, Reading SJ, Ruckley CV. Fibrin sealant reduces suture line bleeding during carotid endarterectomy: a randomised trial. Eur J Vasc Endovasc Surg. 1995;10(1):91–4.10.1016/S1078-5884(05)80203-5 ↗
25. Milne AA, Murphy WG, Reading SJ, Ruckley CV. A randomised trial of fibrin sealant in peripheral vascular surgery. Vox Sang. 1996;70(4):210–2.10.1111/j.1423-0410.1996.tb01328.x ↗
26. Bill TJ, Foresman PA, Rodeheaver GT, Drake DB. Fibrin sealant: a novel method of fixation for an implantable ultrasonic microDoppler probe. J Reconstr Microsurg. 2001;17(4):257–62. doi: 10.1055/s-2001-14517 .10.1055/s-2001-14517 ↗
27. Schenk WG 3rd, Goldthwaite CA Jr., Burks S, Spotnitz WD. Fibrin sealant facilitates hemostasis in arteriovenous polytetrafluoroethylene grafts for renal dialysis access. Am Surg. 2002;68(8):728–32.10.1177/000313480206800814 ↗
28. Taylor LM Jr., Mueller-Velten G, Koslow A, Hunter G, Naslund T, Kline R, et al. Prospective randomized multicenter trial of fibrin sealant versus thrombin-soaked gelatin sponge for suture- or needle-hole bleeding from polytetrafluoroethylene femoral artery grafts. J Vasc Surg. 2003;38(4):766–71.10.1016/S0741-5214(03)00474-9 ↗
29. Sintler MP, Mahmood A, Smith SR, Simms MH, Vohra RK. Randomized trial comparing Quixil surgical sealant with Kaltostat hemostatic dressing to control suture line bleeding after carotid endarterectomy with ePTFE patch reconstruction. World J Surg. 2005;29(10):1259–62. doi: 10.1007/s00268-005-7863-4 .10.1007/s00268-005-7863-4 ↗
30. Spotnitz WD, Burks S. Hemostats, sealants, and adhesives III: a new update as well as cost and regulatory considerations for components of the surgical toolbox. Transfusion. 2012;52(10):2243–55. doi: 10.1111/j.1537-2995.2012.03707.x .10.1111/j.1537-2995.2012.03707.x ↗
31. Hino M, Ishiko O, Honda KI, Yamane T, Ohta K, Takubo T, et al. Transmission of symptomatic parvovirus B19 infection by fibrin sealant used during surgery. Br J Haematol. 2000;108(1):194–5.10.1046/j.1365-2141.2000.01818.x ↗
32. Chambi I, Tasker RR, Gentili F, Lougheed WM, Smyth HS, Marshall J, et al. Gauze-induced granuloma (“gauzoma”): an uncommon complication of gauze reinforcement of berry aneurysms. J Neurosurg. 1990;72(2):163–70. doi: 10.3171/jns.1990.72.2.0163 .10.3171/jns.1990.72.2.0163 ↗
33. Basu S, Marini CP, Bauman FG, Shirazian D, Damiani P, Robertazzi R, et al. Comparative study of biological glues: cryoprecipitate glue, two-component fibrin sealant, and “French” glue. Ann Thorac Surg. 1995;60(5):1255–62. doi: 10.1016/0003-4975(95)00599-G .10.1016/0003-4975(95)00599-G ↗