journal article·2015-03

In vivo wear particles of remelted highly crosslinked polyethylene after total hip arthroplasty: report of four cases

Kanako Hata, Yukihide Minoda, Mitsuhiko Ikebuchi, Shigekazu Mizokawa, Yoichi Ohta, Nobuyuki Miyazaki, Yusuke Miyake, Hiroaki Nakamura

Publisher page

Abstract

This is the first report of in vivo wear particles from four total hip arthroplasties using remelted highly crosslinked polyethylene. The number of particles was (1.51 ± 0.45) × 10(7) g(-1) (mean ± standard error); particle size (equivalent circle diameter), 0.72 ± 0.15 µm; and roundness, 1.45 ± 0.05. Remelted highly crosslinked polyethylene generates fewer, rounder, equivalently sized particles compared with corresponding reported values for particles generated from conventional polyethylene.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. Zahiri C. Assessing activity in joint replacement patients. J Arthroplas. 1998;18:890–5.10.1016/S0883-5403(98)90195-4 ↗
2. Campbell P, Ma S, Schmalzried T, Amstutz HC. Tissue digestion for wear debris particle isolation. J Biomed Mater Res. 1994;28:523–6.10.1002/jbm.820280415 ↗
3. Kobayashi A, Freeman MA, Bonfield W, Kadoya Y, Yamac T, Al-Saffar N, Scott G, Revell PA. Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method. J Bone Jt Surg Br. 1997;79:844–8.10.1302/0301-620X.79B5.7602 ↗
4. Iwakiri K, Iwaki H, Kobayashi A, Minoda Y, Kagiyama H, Kodoya Y, Takaoka K. Characteristics of Hylamer polyethylene particles isolated from peri-prosthetic tissues of failed cemented total hip arthroplasties. J Biomed Mater Res. 2009;91:799–804.10.1002/jbm.b.31458 ↗
5. Willert HG. Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res. 1977;11:157–64.10.1002/jbm.820110202 ↗
6. Kadoya Y, Revell PA, al-Saffar N, Kobayashi A, Scott G, Freeman MA. Bone formation and bone resorption in failed total joint arthroplasties: histomorphometric analysis with histochemical and immunohistochemical technique. J Orthop Res. 1996;14:473–82.10.1002/jor.1100140318 ↗
7. DeHeer DH, Engels JA, DeVries AS, Knapp RH, Beebe JD. In situ complement activation by polyethylene wear debris. J Biomed Mater Res. 2001;54:12–9.10.1002/1097-4636(200101)54:1<12::AID-JBM2>3.0.CO;2-X ↗
8. Amstutz HC, Campbell P, Kossovsky N, Clarke IC. Mechanism and clinical significance of wear debris-induced osteolysis. Clin Orthop Relat Res. 1992;276:7–18.10.1097/00003086-199203000-00003 ↗
9. Harris WH. The problem is osteolysis. Clin Orthop Relat Res. 1995;311:46–53.
10. Matthews JB, Besong AA, Green TR, Stone MH, Wroblewski BM, Fisher J, Ingham E. Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose. J Biomed Mater Res. 2000;52:296–307.10.1002/1097-4636(200011)52:2<296::AID-JBM8>3.0.CO;2-9 ↗
11. Yang SY, Ren W, Park Y, Sieving A, Hsu S, Nasser S, Wooley P. Diverse cellular and apoptotic responses to variant shapes of UHMWPE particles in a murine model of inflammation. Biomaterials. 2002;23:3535–43.10.1016/S0142-9612(02)00032-7 ↗
12. Ries MD, Scott ML, Jani S. Relationship between gravimetric wear and particle generation in hip simulators: conventional compared with cross-linked polyethylene. J Bone Jt Surg Am. 2001;83(Suppl 2 Pt 2):116–22.10.2106/00004623-200100022-00009 ↗
13. Saikko V, Calonius O, Keranen J. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator. J Biomed Mater Res. 2002;63:848–53.10.1002/jbm.10471 ↗
14. Endo M, Tipper JL, Barton DC, Stone MH, Ingham E, Fisher J. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Proc Inst Mech Eng. 2002;216:111–22.10.1243/0954411021536333 ↗