journal article·2015-02Open access

Simple clotting test to detect procoagulant abdominal swabs

Stefanie Krajewski, Tanja Nathan, Bernd Neumann, Sebastian Hoffmann, Martin Abel, Annette Koggel, Christian Schlensak, Hans P. Wendel

Abstract

During surgical procedures, abdominal swabs are routinely used to adsorb blood from the operation field and for the retention of tissues and organs. Due to the material characteristics, abdominal swabs exhibit a slight procoagulant activity, which is usually desirable and mostly harmless. However, during cardiac surgery with heart-lung machine (HLM) support, abnormal clot formation may result in life-threatening thromboembolic complications. Therefore, a simple clotting test (SCT) allowing in vitro detection of abdominal swabs with elevated hypercoagulant potency in the presence of heparinized human blood was developed and validated. In order to establish a SCT, heparinized human blood from 100 donors was incubated with five different cotton abdominal swabs for 30 min at 37 °C and then macroscopically analyzed. In a second study, 10 other swabs were screened with the established SCT (n=11) to confirm its suitability. Scanning electron microscopy, measurements of activated clotting times and thrombin-antithrombin were further performed. In the SCT, the results are dichotomized as negative (no detectable blood clot) and positive (blood clot formation). In the first study, three of the five tested abdominal swabs exhibited hypercoagulant potency in at least 25% of the donors. Calculations using the binomial distribution showed that blood of 11 donors is needed for routine testing with the SCT, which was confirmed in the second study using another 10 swabs. The established SCT can be used for detection of abdominal swabs with an elevated procoagulant potency, thereby minimizing the risk of thromboembolic complications during cardiac surgery with HLM support.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Trauma, Hemostasis, Coagulopathy, Resuscitation · Clinical Laboratory Practices and Quality Control · Hemostasis and retained surgical items

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (6)

Show source-provided references
1. Weerasinghe A, Taylor KM. The platelet in cardiopulmonary bypass. Ann Thorac Surg. 1998;66:2145.10.1016/S0003-4975(98)00749-8 ↗
2. Paparella D, Brister SJ, Buchanan MR. Coagulation disorders of cardiopulmonary bypass: a review. Intens Care Med. 2004;30:1873. doi: 10.1007/s00134-004-2388-0 .10.1007/s00134-004-2388-0 ↗
3. Sadel S. Safety and management of perturbations during cardiopulmonary bypass. Cardiopulmonary bypass principles and techniques of extracorporeal circulation. New York: Springer; 1995. p. 298–308.10.1007/978-1-4612-2484-6_18 ↗
4. Krajewski S, Krauss S, Kurz J, Neumann B, Schlensak C, Wendel HP. Real-time measurement of free thrombin: evaluation of the usability of a new thrombin assay for coagulation monitoring during extracorporeal circulation. Thromb Res. 2014;133:455. doi: 10.1016/j.thromres.2013.12.007 .10.1016/j.thromres.2013.12.007 ↗
5. Krajewski S, Neumann B, Kurz J, et al. Preclinical evaluation of the thrombogenicity and endothelialization of bare metal and surface-coated neurovascular stents. AJNR Am J Neuroradiol. 2014. doi: 10.3174/ajnr.A4109 .
6. Fosgate GT. Modified exact sample size for a binomial proportion with special emphasis on diagnostic test parameter estimation. Stat Med. 2005;24:2857. doi: 10.1002/sim.2146 .10.1002/sim.2146 ↗