journal article·2011-12

High speed insertion of bone fracture fixation pins: a finite element penetration model with experimental comparisons

Matthew P. Prygoski, Timotius Pasang, Steven R. Schmid, Antony J. Lozier

Publisher page

Abstract

A new method of bone fracture fixation is considered in which small pins/darts are dynamically inserted into bone to prevent translation and rotation at the fracture site. An ABAQUS model was developed to analyze dart penetration in cortical and cancellous bone for varying dart diameter, material, and velocity, and cortical thickness. The method is advocated for bioresorbable darts, so polylactide (PLA) and magnesium are the materials examined in this study. Numerical results showed that magnesium darts can achieve full penetration in bone while suffering little damage. The PLA darts penetrated thin bone well, but substantial deformation was seen as the cortical thickness increased, especially for small diameter darts. As partial validation, prototype PLA fixation darts were fired into cadaveric bone with a custom nailer. As in the model, the PLA darts could penetrate thin cortices but saw gross deformation when impacted against thicker bone.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone fractures and treatments · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (49)

Show source-provided references
1. Farley GL. Repairing fractured bones by use of bioabsorbable composites (NASA Technical Brief LAR-16354-1). National Aeronautics and Space Administration, Langley Research Center. 2006.
2. Miller DL, Goswami T. A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing. Clin Biomech. 2007;22:1049–62.10.1016/j.clinbiomech.2007.08.004 ↗
3. Ezquerro F, Jiminez S, Perez A, Prado M, de Diego G, Simon A. The influence of wire positioning upon the initial stability of scaphoid fractures fixed using Kirschner wires: a finite element study. Med Eng Phys. 2007;29:652–60.10.1016/j.medengphy.2006.08.005 ↗
4. Gefen A. Optimizing the biomechanical compatibility of orthopaedic screws for bone fracture fixation. Med Eng Phys. 2002;24:337–47.10.1016/S1350-4533(02)00027-9 ↗
5. Duda GN, Kirchner H, Wilke HJ, Claes L. A method to determine the 3-D stiffness of fracture fixation devices and its application to predict inter-fragmentary movement. J Biomech. 1998;31:247–52.10.1016/S0021-9290(97)00115-2 ↗
6. Staiger MP, Pietak AM, Huadmai J, Dias G. Magnesium and its alloys as orthopedic biomaterials: a review. Biomater. 2006;27:1728–34.10.1016/j.biomaterials.2005.10.003 ↗
7. Yamadi S, Kobayashi S. Effects of strain rate on the mechanical properties of tricalcium phosphate/poly(L-lactide) composites. J Mater Sci: Mater Med. 2009;20:67–74.10.1007/s10856-008-3553-8 ↗
8. Gupta AP, Kumar V. New emerging trends in synthetic biodegradable polymers–polylactide: a critique. Eur Polym J. 2007;43:4053–74.10.1016/j.eurpolymj.2007.06.045 ↗
9. Sarasua JR, Arraiza AL. Crystallinity and mechanical properties of optically pure polylactides and their blends. Polym Eng Sci. 2005;45:745–53.10.1002/pen.20331 ↗
10. Claes LE, Ignatius AA, Rehm KE, Scholz C. New bioresorbable pin for the reduction of small bony fragments: design, mechanical properties and in vitro degradation. Biomater. 1996;17:1621–6.10.1016/0142-9612(95)00327-4 ↗
11. Wen CE, Yamada Y, Shimojima K, Chino Y, Hosokawa H, Mabuchi M. Compressibility of porous magnesium foam: dependence on porosity and pore size. Mater Lett. 2004;58:357–60.10.1016/S0167-577X(03)00500-7 ↗
12. Denkena B, Lucas A. Biocompatible magnesium allows as absorbable implant materials–adjusted surface and subsurface properties by machining processes. Ann CIRP. 2007;56:113–6.10.1016/j.cirp.2007.05.029 ↗
13. Mueller W, de Mele M, Nascimento M, Zeddies M. Degradation of magnesium and its alloys: dependence on the composition of the synthetic biological media. J Biomed Mater Res. 2009;90A:487–95.10.1002/jbm.a.32106 ↗
14. Song WQ, Beggs P, Easton M. Compressive strain-rate sensitivity of magnesium-aluminum die casting alloys. Mater Des. 2009;30:642–8.10.1016/j.matdes.2008.05.050 ↗
15. Witte F, Kaese V, Haferkamp H, Switzer E, Meyer-Lindenberg A, Wirth CJ, Windhagen H. In vivo corrosion of four magnesium alloys and the associated bone response. Biomater. 2005;26:3557–63.10.1016/j.biomaterials.2004.09.049 ↗
16. Xu L, Yu G, Zhang E, Pan F, Yang K. In vivo corrosion behavior of Mg–Mn–Zn alloy for bone implant application. J Biomed Mater Res. 2007;83A:703–11.10.1002/jbm.a.31273 ↗
17. Witte F, Fischer J, Nellesen J, Crostack HA, Kaese V, Pisch A, Beckmann F, Windhagen H. In vitro and in vivo corrosion measurements of magnesium alloys. Biomater. 2006;27:1013–8.10.1016/j.biomaterials.2005.07.037 ↗
18. Ferguson SJ, Weber U, von Rechenberg B, Mayer J. Enhancing the mechanical integrity of the implant-bone interface with BoneWelding® technology: determination of Quasi-Static interfacial strength and fatigue resistance. J Biomed Mater Res Part B. 2006;77B:13–20.10.1002/jbm.b.30427 ↗
19. Kincaid B, Schroder L, Mason J. Measurement of orthopedic cortical bone screw insertion performance in cadaver bone and model materials. Exp Mech. 2007. doi: 10.1007/s11340-007-9056-6 .10.1007/s11340-007-9056-6 ↗
20. Newman DL, Dougherty G, Al Obaid A, Al Hajrasy H. Limitations of clinical CT in assessing cortical thickness and density. Phys Med Biol. 1998;43:619–26.10.1088/0031-9155/43/3/013 ↗
21. Singh S. Ultrasonic non-destructive measurements of cortical bone thickness in human cadaver femur. Ultrason. 1989;27:107–13.10.1016/0041-624X(89)90022-X ↗
22. Moilanen P, Talmant M, Bousson V, Nicholson PHF, Cheng S, Timonen J, Laugier P. Ultrasonically determined thickness of long cortical bones: two-dimensional simulations of in vitro experiments. J Acoust Soc Am. 2007;122(3):1818–26.10.1121/1.2756758 ↗
23. MacNeil JA, Boyd SK. Accuracy of high-resolution peripheral qualitative computed tomography for measurement of bone quality. Med Eng Phys. 2007;29:1096–105.10.1016/j.medengphy.2006.11.002 ↗
24. ABAQUS User’s Manual. ABAQUS 6.8-EF2, SIMULIA, Dassault Systemes.
25. Li Z, Lambros J. Strain rate effects on the thermomechanical behavior of polymers. Int J Solids Struct. 2001;38:3549–62.10.1016/S0020-7683(00)00223-7 ↗
26. Hansen U, Zioupos P, Simpson R, Currey JD, Hynd D. The effect of strain rate on the mechanical properties of human cortical bone. J Biomech Eng. 2008. doi: 10.1115/1.2838032 .10.1115/1.2838032 ↗
27. McElhaney JH, Byars EF. Dynamic response of biological materials. In: Winter annual meeting of the American Society of Mechanical Engineers, ASME Human Factors Division. ASME. 1965.
28. Linde F, Norgaard P, Hvid I, Odgaard A, Soballe K. Mechanical properties of trabecular bone. dependency on strain rate. J Biomech. 1991;24(9):803–9.10.1016/0021-9290(91)90305-7 ↗
29. Shim VPW, Yang LM, Lie JF, Lee VS. Characterisation of the dynamic compressive mechanical properties of cancellous bone from the human cervical spine. Int J Impact Eng. 2005;32:525–40.10.1016/j.ijimpeng.2005.03.006 ↗
30. Ouyang J, Yang GT, Wu WZ, Zhu QA, Zhong SZ. Biomechanical characteristics of human trabecular bone. Clin Biomech. 1997;12:522–4.10.1016/S0268-0033(97)00035-1 ↗
31. Morgan EF, Keaveny TM. Dependence of yield strain of human trabecular bone on anatomic site. J Biomech. 2001;34:569–77.10.1016/S0021-9290(01)00011-2 ↗
32. Ford CM, Keaveny TM. The dependence of shear failure properties of trabecular bone on apparent density and trabecular orientation. J Biomech. 1996;29(10):1309–17.10.1016/0021-9290(96)00062-0 ↗
33. Jepsen KJ, Davy DT. Comparison of damage accumulation measures in human cortical bone. J Biomech. 1997;30(9):891–4.10.1016/S0021-9290(97)00036-5 ↗
34. Mendelson A. Elastic-plastic torsion problem for strain-hardening materials (NASA Technical Note D-4391). National Aeronautics and Space Administration, Lewis Research Center. 1968.
35. Garnier KB, Dumas R, Rumelhart C, Arlot ME. Mechanical characterization in shear of human femoral cancellous bone: torsion and shear tests. Med Eng Phys. 1999;21:641–9.10.1016/S1350-4533(99)00096-X ↗
36. Rincon-Kohli L, Zysset PK. Multi-axial mechanical properties of human trabecular bone. Biomech Model Mechanobiol. 2009;8:195–208.10.1007/s10237-008-0128-z ↗
37. Kopperdahl DL, Keaveny TM. Yield strain behaviour of trabecular bone. J Biomech. 1998;31:601–8.10.1016/S0021-9290(98)00057-8 ↗
38. Norman TL, Nivargikar SV, Burr DB. Resistance to crack growth in human cortical bone is greater in shear than in tension. J Biomech. 1996;29:1023–31.10.1016/0021-9290(96)00009-7 ↗
39. Feng Z, Rho J, Han S, Ziv I. Orientation and loading condition dependence of fracture toughness in cortical bone. Mater Sci Eng C. 2000;11:41–6.10.1016/S0928-4931(00)00142-9 ↗
40. Cook RB, Zioupos P. The fracture toughness of cancellous bone. J Biomech. 2009;42:2054–60.10.1016/j.jbiomech.2009.06.001 ↗
41. Tomar V. Insights into the effects of tensile and compressive loadings on microstructure dependent fracture of trabecular bone. Eng Fract Mech. 2009;76:884–97.10.1016/j.engfracmech.2008.12.013 ↗
42. Lim LT, Auras R, Rubino M. Processing technologies for poly(lactic acid). Prog Polym Sci. 2008;33:820–52.10.1016/j.progpolymsci.2008.05.004 ↗
43. Haibach R. Injection-molding degradation of biodegradable polylactide. Technical conference of the society of plastics engineers. ANTEC. 2007;4:2043–7.
44. Doblare M, Garcia JM, Gomez MJ. Modelling bone tissue fracture and healing: a review. Eng Fract Mech. 2004;71:1809–40.10.1016/j.engfracmech.2003.08.003 ↗
45. Shin H, Lee HJ, Yoo YH, Lee W. A determination procedure for element elimination criterion in finite element analysis of high-strain-rate impact/penetration phenomena. JSME Int J Ser A. 2004;47(1):35–41.10.1299/jsmea.47.35 ↗
46. Campbell J, Vignjevic R. Development of lagrangian hydrocode modelling for debris impact damage prediction. Int J Impact Eng. 1997;20:143–52.10.1016/S0734-743X(97)87488-X ↗
47. Chen EP. Numerical simulation of penetration of aluminum targets by spherical-nose steel rods. Theor Appl Fract Mech. 1995;22:159–64.10.1016/0167-8442(94)00056-7 ↗
48. MatWeb Material Property Data: www.matweb.com . Accessed 1 Feb 2010.
49. Dong XN, Guo XE. The dependence of transversely isotropic elasticity of human femoral cortical bone on porosity. J Biomech. 2004;37:1281–7.10.1016/j.jbiomech.2003.12.011 ↗