journal article·2015-09

Analysis of clinically relevant mechanical and thermal characteristics of titanium foam spinal implants during drilling

Kiyoshi Ito, Tetsuyoshi Horiuchi, Takahiro Murata, Kazuhiro Hongo

Publisher page

Abstract

Although high biocompatibility promotes the use of titanium (Ti) alloy in spinal implants, this material shows high stiffness, which is an issue for removal by drilling. The recently developed, porous Ti foam implants, which have shown enhanced osteoformation, may overcome this flaw. Thus, this study aimed to compare the mechanical and thermal characteristics of Ti-foam (80 % porosity) and conventional Ti alloy (0 % porosity) implants drilled in clinically relevant conditions. Mechanical properties were analyzed by measuring axial and torque forces using a pressure sensor with a drill of 2.5-mm diameter at a rotation frequency of 20 Hz. Thermography was used to evaluate the heat generated by a diamond burr attached to a high-speed (80,000 rpm) drill. The torque and axial strengths of Ti foam (13.63 ± 1.43 and 82.60 ± 7.78 N, respectively) were significantly lower (P = 0.001) than those of Ti alloy (73.58 ± 13.60 and 850.72 ± 146.99 N, respectively). Furthermore, irrigation reduced the area of local heating for Ti foam to 56-82 % of that for Ti alloy, indicating lower thermal conductivity. These data suggest that the use of Ti foam implants may be advantageous in cases with a probability of implant drilling in the future.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Spine and Intervertebral Disc Pathology · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. Meier U, Gräwe A, Hajdukova A. Clinical experience with Cespace, the new intervertebral disc spacer by Aesculap for spondylodesis of the cervical spine, in comparison with similar products by Weber, Intromed, and Acromed. Neurosurg Q. 2003;13:40–50.10.1097/00013414-200303000-00004 ↗
2. Hacker RJ. A randomized prospective study of an anterior cervical interbody fusion device with a minimum of 2 years of follow-up results. J Neurosurg. 2000;93:222–6.
3. Koyama T, Handa J. Porous hydroxyapatite ceramics for use in neurosurgical practice. Surg Neurol. 1986;25:71–3.10.1016/0090-3019(86)90118-7 ↗
4. Hauerberg J, Kosteljanetz M, Bøge-Rasmussen T, Dons K, Gideon P, Springborg JB, Wagner A. Anterior cervical discectomy with or without fusion with ray titanium cage: a prospective randomized clinical study. Spine (Phila Pa 1976). 2008;33:458–64.10.1097/BRS.0b013e3181657dac ↗
5. Moreland DB, Asch HL, Clabeaux DE, Castiglia GJ, Czajka GA, Lewis PJ, Egnatchik JG, Cappuccino A, Huynh L. Anterior cervical discectomy and fusion with implantable titanium cage: initial impressions, patient outcomes and comparison to fusion with allograft. Spine J. 2004;4:184–91.10.1016/j.spinee.2003.05.001 ↗
6. Hida K, Iwasaki Y, Yano S, Akino M, Seki T. Long-term follow-up results in patients with cervical disk disease treated by cervical anterior fusion using titanium cage implants. Neurol Med Chir (Tokyo). 2008;48:440–62.10.2176/nmc.48.440 ↗
7. Lausmaa J, Mattssin L, Rolander U, Kasemo B. Chemical composition and morphology of titanium surface oxide. Mater Res. 1986;55:351–9.10.1557/PROC-55-351 ↗
8. Huang HN, Yang J, Goto M, Watanabe T. Young’s modulus of sintered materials for structural machine parts. J Jpn Soc Powder Metal. 1998;45:896–900 (in Japanese).10.2497/jjspm.45.896 ↗
9. Lausmaa J, Kasemo B, Hansson S. Accelerated oxide growth on titanium implants during autoclaving caused by fluorine contamination. Biomaterials. 1985;6:23–7.10.1016/0142-9612(85)90033-X ↗
10. Bärlocher CB, Barth A, Krauss JK, Binggeli R, Seiler RW. Comparative evaluation of microdiscectomy only, autograft fusion, polymethylmethacrylate interposition, and threaded titanium cage fusion for treatment of single-level cervical disc disease: a prospective randomized study in 125 patients. Neurosurg Focus. 2002;12:E4.10.3171/foc.2002.12.1.5 ↗
11. Imwinkelried T. Mechanical properties of open-pore titanium foam. J Biomed Mater Res A. 2007;81:964–70.10.1002/jbm.a.31118 ↗
12. Caroli E, Orlando ER, D’Andrea G, Ferrante L. Anterior cervical fusion with interbody titanium cage containing surgical bone site graft: our institution’s experience in 103 consecutive cases of degenerative spondylosis. J Spinal Disord Tech. 2007;20:216–20.10.1097/01.bsd.0000211272.97109.b8 ↗
13. Fujibayashi S, Takemoto M, Neo M, Matsushita T, Kokubo T, Doi K, Ito T, Shimizu A, Nakamura T. A novel synthetic material for spinal fusion: a prospective clinical trial of porous bioactive titanium metal for lumbar interbody fusion. Eur Spine J. 2011;20:1486–95.10.1007/s00586-011-1728-3 ↗
14. Kim P, Wakai S, Matsuo S, Moriyama T, Kirino T. Bisegmental cervical interbody fusion using hydroxyapatite implants: surgical results and long-term observation in 70 cases. J Neurosurg. 1998;88:21–7.10.3171/jns.1998.88.1.0021 ↗
15. Yamagata T, Takami T, Uda T, Ikeda H, Nagata T, Sakamoto S, Tsuyuguchi N, Ohata K. Outcomes of contemporary use of rectangular titanium stand-alone cages in anterior cervical discectomy and fusion. Cage subsidence and cervical alignment. J Clin Neurosci. 2012;19:1673–8.10.1016/j.jocn.2011.11.043 ↗
16. Kato K, Yamamoto A, Ochiai S, Daigo Y, Isobe T, Matano S. Cell proliferation, corrosion resistance and mechanical properties of novel titanium foam with sheet shape. Mater Trans. 2012;53:724–32.10.2320/matertrans.M2011325 ↗
17. Oh IH, Nomura N, Hanada S. Microstructures and mechanical properties of porous titanium compacts prepared by powder sintering. Mater Trans. 2002;43:443–8.10.2320/matertrans.43.443 ↗
18. Ito K, Horiuchi T, Arai Y, Kawahara I, Hongo K. Histological, mechanical, and radiological study of osteoformation in titanium foam implants. Acta Neurochir (Wien). 2014;156:2165–72.10.1007/s00701-014-2122-9 ↗
19. Takemoto M, Fujibayashi S, Neo M, So K, Akiyama N, Matsushita T, Kokubo T, Nakamura T. A porous bioactive titanium implant for spinal interbody fusion: an experimental study using a canine model. J Neurosurg Spine. 2007;4:435–43.10.3171/SPI-07/10/435 ↗
20. Ito M, Kotani Y, Hojo Y, Abumi K, Kadosawa T, Minami A. Evaluation of hydroxyapatite ceramic vertebral spacers with different porosities and their binding capability to the vertebral body: an experimental study in sheep. J Neurosurg Spine. 2007;6:431–7.10.3171/spi.2007.6.5.431 ↗
21. Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials. 2007;28:4845–69.10.1016/j.biomaterials.2007.07.013 ↗
22. van Jonbergen HP, Spruit M, Anderson PG, Pavlov PW. Anterior cervical interbody fusion with a titanium box cage: early radiological assessment of fusion and subsidence. Spine J. 2004;5:645–9.10.1016/j.spinee.2005.07.007 ↗
23. Willie BM, Yang X, Kelly NH, Merkow J, Gagne S, Ware R, Wright TM, Bostrom MP. Osseointegration into a novel titanium foam implant in the distal femur of a rabbit. J Biomed Mater Res B Appl Biomater. 2010;92:479–88.10.1002/jbm.b.31541 ↗
24. Pall Singh TS, Yusoff AH, Chian YK. How safe is high-speed burring in spine surgery? An in vitro study on the effect of rotational speed and heat generation in the bovine spine. Spine (Phila Pa 1976). 2015;40(15):E866–72.10.1097/BRS.0000000000000985 ↗