journal article·2007-04

Preoperative opacification of acrylic intraocular lenses in storage

C. M. Pratt, S. Barton, E. McGonigle, M. Kishi, P. J. S. Foot

Publisher page

Abstract

The preoperative opacification of acrylic intraocular lenses (IOLs) was investigated in order to determine its cause. Opacified IOLs were examined by energy dispersive X-ray (EDX), the buffer solutions were analysed by inductively coupled plasma optical emission spectroscopy (ICP-OES) and the rubber seals used in the bottles in which the IOLs were stored were ashed and tested. The deposit covering the opacified lenses contained a significant amount of zinc, which was absent from fresh IOLs and buffer solution. The source of this was found to be the rubber seals used to seal the glass bottles in which the IOLs were stored. There were two types of rubber seals used, red and grey in colour. The buffer solutions in which opacification had occurred was also contaminated with zinc, but this was only noticeable when using the red seals. This contamination was reproduced by boiling red seals in fresh buffer solution for eighty minutes, to simulate autoclaving. It was concluded that zinc from the zinc oxide used as filler in the rubber seals was leaching into the buffer solution and causing the IOLs to become opacified. This was found to be much worse in the case of the red seals than for the grey ones. However, minute crystals were found on the IOLs stored using the grey ones, which could potentially act as nucleation points for postoperative opacification.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Intraocular Surgery and Lenses · Traumatic Ocular and Foreign Body Injuries · Retinal and Macular Surgery

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. J. RAM J, S. K. PANDEY, D. J. APPLE, L. WERNER, G. S. BRAR, R. SINGH, K. P. CHAUDHARY and A. GUPTA, J. Cataract Refract. Surg. 27(2001) 1039.10.1016/S0886-3350(00)00841-5 ↗
2. D. J. APPLE, Q. PENG, S. N. ARTHUR, L. WERNER, J. H. MERRITT, L. G. VARGAS, D. S. M. HODDINOTT, M. ESCOBAR-GOMEZ and J. M. SCHMIDBAUER, Ophthalmology 109(2002) 1666.10.1016/S0161-6420(02)01122-3 ↗
3. E. J. HOLLICK, D. J. SPALTON, P. G. URSELL, M. V. PANDE, S. A. BARMAN, J. F. BOYCE and K. TILLING, Ophthalmology 106(1999) 49.10.1016/S0161-6420(99)90047-7 ↗
4. E. J. HOLLICK, D. J. SPALTON, P. G. URSELL, W. R. MEACOCK, S. A. BARMAN and J. F. BOYCE, Am. J. Ophthalmology 129(2000) 577.10.1016/S0002-9394(99)00447-X ↗
5. A. A. R. EL-OSTA, D. J. SPALTON and J. MARSHALL, J. Cataract Refract. Surg. 29(2003) 1593.10.1016/S0886-3350(03)00221-9 ↗
6. G. WEJDE, M. KUGELBERG and C. ZETTERSTRÖM, J. Cataract Refract. Surg. 29(2003) 1556.10.1016/S0886-3350(03)00342-0 ↗
7. D. J. APPLE, Q. PENG, N. VISESSOOK, L. WERNER, S. K. PANDEY, M. ESCOBAR-GOMEZ, J. RAM and G. U. AUFFARTH, Ophthalmology 108(2001) 505.10.1016/S0161-6420(00)00589-3 ↗
8. H. K. VARMA, K. SREENIVASAN, Y. YOKOGAWA and A. HOSUMI, Biomaterials 24(2003) 297.10.1016/S0142-9612(02)00318-6 ↗
9. G. PROSDOCIMO, G. TASSINARI, M. SALA, A. D. BIASE, P. G. TOSCHI, M. GISMONDI and U. CORBANESE, J. Cataract Refract. Surg. 29(2003) 1551.10.1016/S0886-3350(02)02051-5 ↗
10. D. TOGNETTO, L. TOTO, G. SANGUINETTI and G. RAVALICO, J. Cataract Refract. Surg. 28(2002) 1211.10.1016/S0886-3350(02)01353-6 ↗
11. N. Z. GREGORI, T. S. SPENCER, N. MAMALIS and R. J. OLSON, J. Cataract Refract. Surg. 28(2002) 1262.10.1016/S0886-3350(02)01224-5 ↗
12. A. MIYATA, N. UCHIDA, K. NAKAJIMA and S. YAGUCHI, Jpn. J. Ophthalmol. 45(2001) 564.10.1016/S0021-5155(01)00429-4 ↗
13. E. WILKINS, R. J. OLSON, Am. J. Ophthalmol. 132(2001) 783.10.1016/S0002-9394(01)01090-X ↗
14. K. KATO, M. NISHIDA, H. YAMANE, K. NAKAMAE, Y. TAGAMI and K. TETSUMOTO, J. Cataract Refract. Surg. 27(2001) 1493.10.1016/S0886-3350(01)00895-1 ↗
15. G. CHRISTIANSEN, F. J. DURCAN, R. J. OLSON and K. CHRISTIANSEN, J. Cataract Refract. Surg. 27(2001) 728.10.1016/S0886-3350(00)00700-8 ↗
16. O. OMAR, A. PIRAYESH, N. MAMALIS and R. J. OLSON, J. Cataract Refract. Surg. 24(1998) 107.10.1016/S0886-3350(98)80082-5 ↗
17. J. H. HANKS and R. E. WALLACE, Proc. Soc. Exp. Biol. Med. 71(1949) 196.10.3181/00379727-71-17131 ↗
18. W. BYRNE, in “Reverse Osmosis: a Practical Guide for Industrial Users” (Tall Oaks Publishing, Littleton, CO., 1995).
19. T. H. MELTZER, in “High-Purity Water Preparation for the Semiconductor, Pharmaceutical, and Power industries” (Tall Oaks Publishing, Littleton, CO., 1993) p. 261–265.
20. J. J. LOHMILLER and N. S. LIPMAN, Contemp. Top. Lab. Anim. 37(1998) 62.