Sutured calf pericardium: influence of the type and angle of the suture on mechanical behavior
Source abstract
Abstract
Careful selection of the biological tissue to be used in cardiac bioprostheses and a thorough knowledge of its mechanical behavior, facilitating both the prediction of this behavior and the interactions between the tissue and the other materials employed, is the best approach to designing a durable implant. For this purpose, a study involving uniaxial tensile testing of calf pericardium was carried out. Two sets of three contiguous strips of tissue were obtained from each pericardial membrane, to perform a total of 144 trials. Two samples were sewn with one of four commercially available suture materials: Gore-Tex, nylon, Prolene and silk. In each set of three samples, the center strip remained intact and unsutured to serve as a control, while the left-hand strip was sutured at a 45 degrees angle with respect to the longitudinal axis and the right-hand strip was sewn at a 90 degrees angle. All the samples were tested until rupture. The results demonstrated a significant loss of mean load (p<0.01) in the sutured samples at rupture. The angle of the suture had no influence on these results, although the stress/strain curves showed that, as the tensile stress increased, the mechanical behaviors were less uniform. The rupture of the collagen fibers could explain this phenomenon. The pericardium sutured with Gore-Tex presented a greater strain, or deformation (elongation), at lower levels of stress, regardless of the angle of the suture. The tissue selection criteria, based on the use of paired samples, enabled a correct prediction of the mechanical behavior of the tissue, with excellent correlation coefficients (>0.98) and a high degree of homogeneity in the results.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Surgical Sutures and Adhesives · Cardiac Valve Diseases and Treatments · Infective Endocarditis Diagnosis and Management
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. T. J. Edwards, S. A. Livesey, I. A. Simpson, J. L. Monro and J. K. Ross, Ann. Thorac. Surg. 60 (1995) S211.10.1016/0003-4975(95)00220-F ↗
2. W. Vongpatanasin, L. D. Hillis and R. A. Lang, N. Engl. J. Med. 335 (1996) 407.10.1056/NEJM199608083350607 ↗
3. F. Hariza, G. Papouin, B. Barratt-Boyes, G. Christie and R. Whitlock, J. Heart Valve Dis. 4 (1996) 35.
4. R. J. Levy, ibid. 3 (1994) 101.
5. E. Jorge-Herrero, P. Fernandez, M. Gutierrez and J. L. Castillo-Oolivares, Biomaterials 12 (1991) 683.10.1016/0142-9612(91)90117-S ↗
6. A. I. Munro, W. R. E. Jamieson, G. F. O. Tyers and E. Germann, Ann. Thorac. Surg. 59 (1995) S470.10.1016/0003-4975(95)00271-L ↗
7. L. H. Burr, R. E. Jamiesson, A. I. Munro, R. T. Miyagishima and E. Germann, ibid. 60 (1995) S264.10.1016/0003-4975(95)00300-A ↗
8. D. D. Glower, W. D. White, L. R. Smith, W. G. Young, H. N. Oldham, W. G. Wolfe and J. E. Lowe, J. Thorac. Cardiovasc. Surg. 109 (1995) 877.10.1016/S0022-5223(95)70311-X ↗
9. S. C. Cannegieter, F. R. Rosendal and E. Briet, Circulation 89 (1994) 635.10.1161/01.CIR.89.2.635 ↗
10. G. L. Grunkemeier, W. R. E. Jamieson, D. C. Miller and A. Starr, J. Thorac. Cardiovasc. Surg. 108 (1994) 709.10.1016/S0022-5223(94)70298-5 ↗
11. J. M. Bernal, J. M. Rabasa, R. Lopez, F. Nistal, R. Muñiz and J. M. Revuelta, Ann. Thorac. Surg. 60 (1995) S248.10.1016/0003-4975(95)00218-A ↗
12. G. F. O. Tyers, W. R. Jamieson, I. A. Munro, E. Germann, L. H. Burr, R. T. Miyagishima and L. Ling, ibid. 60 (1995) S464.10.1016/0003-4975(95)00302-2 ↗
13. P. D. Kent, H. D. Tazelaar, W. D. Edwards and T. A. Orszulak, Cardiovasc. Pathol. 7 (1998) 9.10.1016/S1054-8807(97)00040-9 ↗
14. J. M. García Páez, A. Carrera, J. V. García Sestafe, E. Jorge Herrero, R. Navidad, A. Cordon, I. Candela and J. L. Castillo-Olivares, J. Biomed. Mater. Res. 30 (1996) 47.10.1002/(SICI)1097-4636(199601)30:1<47::AID-JBM7>3.0.CO;2-R ↗
15. J. M. Garcia Páez, A. Carrera, J. V. Garcia Sestafe, E. Jorge, I. Millan, I. Candela and J. L. Castillo-Olivares, J. Thorac. Cardiovasc. Surg. 100 (1990) 580.10.1016/S0022-5223(19)35503-5 ↗
16. A. Carrera, J. M. García Páez, J. V. García Sestafe, E. Jorge, R. Navidad, A. Cordon and J. L. Castillo-Olivares, J. Mater. Sci.: Mater. Med. 9 (1998) 77.
17. J. M. Garcia Páez, A. Carrera, E. Jorge Herrero, I. Millan, R. Navidad, I. Candela, J. V. Garcia Sestafe and J. L. Castillo-Olivares, Biomaterials 5 (1994) 172.10.1016/0142-9612(94)90063-9 ↗
18. A. Carrera, J. M. Garcia Páez, J. V. Garcia Sestafe, E. Jorge Herrero, J. Salvador, A. Cordon and J. L. Castillo-Olivares, J. Biomed. Mater. Res. 39 (1998) 568.10.1002/(SICI)1097-4636(19980315)39:4<568::AID-JBM10>3.0.CO;2-3 ↗
19. J. Bustamante, J. Santamaria, O. Infante, P. Flores and A. Juarez, Arch. Inst. Cardiol. Mex. 66 (1996) 229.
20. D. B. Smith, M. S. Sacks, P. M. Pattany and R. Schroeder, J. Heart Valve Dis. 6 (1997) 424.
21. E. A. Trowbridge, Crit. Rev. Biocompatibility 5 (1989) 105.
22. M. Sacks, C. J. Chuong and R. More, A.S.A.I.O.J. 40 (1994) M632.
23. D. Simionescu, A. Simionescu and R. Deac, J. Biomed. Mater. Res. 27 (1993) 697.10.1002/jbm.820270602 ↗
24. E. D. Hiester and M. S. Sacks, ibid. 39 (1998) 207.10.1002/(SICI)1097-4636(199802)39:2<207::AID-JBM6>3.0.CO;2-T ↗
25. E. D. Hiester and M. S. Sacks, ibid. 39 (1998) 215.10.1002/(SICI)1097-4636(199802)39:2<215::AID-JBM7>3.0.CO;2-S ↗
26. D. M. Braile, M. J. Soares, D. R. Souza, D. A. Ramirez, S. Suzigan and M. F. Godoy, J. Heart Valve Dis. 7 (1998) 202.
27. J. M. García Páez, E. Jorge, A. Carrera, I. Millan, A. Rocha, P. Calero, A. Cordon, N. Sainz and J. L. Castillo-Olivares, Biomaterials 22 (2001) 2731.10.1016/S0142-9612(01)00014-X ↗