In-vitro study of the wear behavior of telescopic crowns made of CoCr, zirconia or PEEK

PC. Pott, N. v. Maltzahn, C. Brachmann, M. Stiesch, P. Kohorst

Abstract

Abstract Purpose: Double-crown-retained dentures (DCRD) are an established treatment in dentistry. In some cases, the retention between primary crown (PC) and secondary crown (SC) loosens due to wear during daily handling of the denture. The aim of the present study was to examine modern materials for PCs and SCs with regard to their wear behavior. Materials and Methods: Cyclic pull-off tests were conducted on each 40 specimens in five test groups. PCs made of CoCr, PEEK and ZrO 2 were cemented onto a prepared resin tooth. SCs were made of the same materials and combined to the following PC-SC combinations: CoCr-CoCr, CoCr-PEEK, PEEK-PEEK, ZrO 2 -PEEK, ZrO 2 -ZrO 2 . The wear areas on the contact surfaces between the PCs and the SCs were examined on SEM images. Results: Wear marks in form of scratches, chipping, ductile deformation or combinations of these forms were observed on the PCs and SCs in the various material combinations. The greatest wear on PCs was observed in the PEEK-PEEK group, while the greatest wear on SCs was observed in the ZrO 2 -ZrO 2 group. The least wear was observed on SCs made of PEEK in combination with PCs made of ZrO 2 . Conclusion: When using modern materials for DCRDs, the combination of different materials for PCs and SCs must be taken into account. The data found in this study show that only minor wear occurs at SCs made of PEEK, especially in combination with PCs made of ZrO 2 . Therefore, this combination seems particularly suitable for increasing the longevity of DCRDs. Graphical Abstract
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Endodontics and Root Canal Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. Kopzon V, Raedel M. Outcomes of abutment teeth with double crowns over an observation period of 27 years. J Prosthodont Res. 2023;67:518–23.10.2186/jpr.JPR_D_22_00165 ↗
2. Widbom T, Löfquist L, Widbom C, Söderfeldt B, Kronström M. Tooth-supported telescopic crown-retained dentures: an up to 9-year retrospective clinical follow-up study. Int J Prosthodont. 2004;17:29–34.
3. Zafiropoulos GG, Abuzayeda M, Murray CA, Baig MR. Double crown-retained removable prostheses supported by implants or teeth and implants: a long-term clinical retrospective evaluation. Med Princ Pr. 2023;32:61–70.10.1159/000529154 ↗
4. Schwindling FS, Dittmann B, Rammelsberg P. Double-crown-retained removable dental prostheses: a retrospective study of survival and complications. J Prosthet Dent. 2014;112:488–93.10.1016/j.prosdent.2014.02.017 ↗
5. Luft V, Pospiech P, Schurig A, Schmitter M. In vitro investigations on retention force behavior of conventional and modern double crown systems. Dent Mater. 2021;37:191–200.10.1016/j.dental.2020.10.028 ↗
6. Bayer S, Kraus D, Keilig L, Gölz L, Stark H, Enkling N. Wear of double crown systems: electroplated vs. casted female part. J Appl Oral Sci. 2012;20:384–91.10.1590/S1678-77572012000300015 ↗
7. Emera RMK, Askar O. Surface wear and retention force of zirconia and PEKK implant-retained crowns. Eur J Prosthodont Restor Dent. 2024;32:20–27.
8. Abdel Hamid SM, Selima RA, Basiony MZ. Surface topography changes and wear resistance of different non-metallic telescopic crown attachment materials in implant retained overdenture (prospective comparative in vitro study). BMC Oral Health. 2024;24:1123.10.1186/s12903-024-04839-w ↗
9. Arnold C, Schweyen R, Boeckler A. Retention force of removable partial dentures with CAD-CAM-Fabricated telescopic crowns. Materials. 2020;13:3228.10.3390/ma13143228 ↗
10. Dabrowa T, Dobrowolska A, Wieleba W. The role of friction in the mechanism of retaining the partial removable dentures with double crown system. Acta Bioeng Biomech. 2013;15:43–8.
11. Eisenburger M, Tscherntischek H. Clinical-technical comparison of the long-term success of clasp-retained dentures and telescopic prostheses. Dtsch Zahnärztl Z. 1998;53:257–9.
12. Bayer S, Stark H, Gölz L, Keilig L, Kraus D, Hansen A, et al. Clinical retention force development of double crowns. Clin Oral Investig. 2012;16:407–11.10.1007/s00784-011-0530-2 ↗
13. Priester M, Müller WD, Beuer F, Schmidt F, Schwitalla AD. Performance of PEEK based telescopic crowns, a comparative study. Dent Mater. 2021;37:1667–75.10.1016/j.dental.2021.08.020 ↗
14. Liu Y, Fang M, Zhao R, Liu H, Li K, Tian M, et al. Clinical applications of polyetheretherketone in removable dental prostheses: accuracy, characteristics, and performance. Polym. 2022;14:4615.10.3390/polym14214615 ↗
15. Çelik Güven M, Tuna M, Bozdağ E, Öztürk GN, Bayraktar G. Comparison of retention forces with various fabrication methods and materials in double crowns. J Adv Prosthodont. 2017;9:308–14.10.4047/jap.2017.9.4.308 ↗
16. Turp I, Bozdağ E, Sünbüloğlu E, Kahruman C, Yusufoğlu I, Bayraktar G. Retention and surface changes of zirconia primary crowns with secondary crowns of different materials. Clin Oral Investig. 2014;18:2023–35.10.1007/s00784-013-1183-0 ↗
17. Schimmel M, Walther M, Al-Haj Husain N, Igarashi K, Wittneben J, Abou-Ayash S. Retention forces between primary and secondary CAD/CAM manufactured telescopic crowns: an in vitro comparison of common material combinations. Clin Oral Investig. 2021;25:6297–307.10.1007/s00784-021-03928-2 ↗