Mineralized collagen-enhanced bone cement: A prospective, randomized controlled trial in total knee arthroplasty
Source abstract
Abstract
Total knee arthroplasty (TKA) is a common procedure for end-stage osteoarthritis (OA). Traditional polymethylmethacrylate (PMMA) bone cement used in TKA has limitations, including lack of osteointegration and higher modulus than bone. We developed a novel bone cement, mineralized collagen (MC)-PMMA, to address these issues. In a prospective, randomized controlled trial, we compared TKA outcomes using MC-PMMA versus traditional PMMA (T-PMMA) in 34 patients with bilateral late-stage osteoarthritis. Evaluated parameters included patient-reported outcome measures (PROMs), knee range of motion, pain scores, complications, and radiographic evaluations over a 45.8-month follow-up. The MC-PMMA group showed significantly improved Knee Society function scores at one-year follow-up. No significant differences were found between groups in other PROMs, knee range of motion, or pain scores. Radiographic evaluations revealed no differences in postoperative Hip-Knee-Ankle (HKA) angle, anatomical axis angle, or radiolucent lines. Complication rates were similar, with no infections, aseptic loosening, peri-prosthetic fractures, or revisions. MC-PMMA is a promising biomaterial for TKA, offering comparable safety and mid-term clinical outcomes to T-PMMA. Its use may lead to earlier functional recovery, highlighting the potential of nanomaterials in orthopedic applications. Trial registration number: ChiCTR1800014811 (02/07/2018).
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Knee injuries and reconstruction techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Canovas F, Dagneaux L. Quality of life after total knee arthroplasty. Orthop Traumatol Surg Res 2018;104:S41–S46.10.1016/j.otsr.2017.04.017 ↗
2. Oonishi H, Akiyama H, Takemoto M, Kawai T, Yamamoto K, Yamamuro T, et al. The long-term in vivo behavior of polymethyl methacrylate bone cement in total hip arthroplasty. Acta Orthopaed. 2011;82:553–8.10.3109/17453674.2011.625538 ↗
3. Sugino A, Miyazaki T, Kawachi G, Kikuta K, Ohtsuki C. Relationship between apatite-forming ability and mechanical properties of bioactive PMMA-based bone cement modified with calcium salts and alkoxysilane. J Mater Sci Mater Med. 2008;19:1399–405.10.1007/s10856-007-3257-5 ↗
4. Mercurio M, Gasparini G, Sanzo V, Familiari F, Castioni D, Galasso O. Cemented total knee arthroplasty shows less blood loss but a higher rate of aseptic loosening compared with cementless fixation: an updated meta-analysis of comparative studies. J Arthroplast. 2022;37:1879.10.1016/j.arth.2022.04.013 ↗
5. Newman JM, Sodhi N, Dekis JC, Khlopas A, Piuzzi NS, Sultan AA, et al. Survivorship and functional outcomes of cementless versus cemented total knee arthroplasty: a meta-analysis. J Knee Surg. 2020;33:270–8.10.1055/s-0039-1678525 ↗
6. Li T, Weng X, Bian Y, Zhou L, Cui F, Qiu Z Influence of Nano-HA coated bone collagen to acrylic (Polymethylmethacrylate) Bone cement on mechanical properties and bioactivity. PLoS ONE. 2015;10:e0129018.10.1371/journal.pone.0129018 ↗
7. Zhang Z, Li Z, Zhang C, Liu J, Bai Y, Li S, et al. Biomimetic intrafibrillar mineralized collagen promotes bone regeneration via activation of the Wnt signaling pathway. Int J Nanomed. 2018;13:7503–16.10.2147/IJN.S172164 ↗
8. Tao C-S, Qiu Z-Y, Meng Q-Y, Wu J-J, Liu F, Wang C-M, et al. Mineralized collagen incorporated polymethyl methacrylate bone cement for percutaneous vertebroplasty and percutaneous kyphoplasty. J Biomater Tissue Eng. 2014;4:1100–6.10.1166/jbt.2014.1250 ↗
9. Bach CM, Biedermann R, Goebel G, Mayer E, Rachbauer F. Reproducible assessment of radiolucent lines in total knee arthroplasty. Clin Orthopaed Related Res. 2005;434:183-810.1097/01.blo.0000153077.79573.a4 ↗
10. Yang J, Heckmann ND, Nahhas CR, Salzano MB, Ruzich GP, Jacobs JJ, et al. Early outcomes of a modern cemented total knee arthroplasty is tibial loosening a concern? Bone Jt J. 2021;103B:51–8.10.1302/0301-620X.103B6.BJJ-2020-1972.R1 ↗
11. Nakama GY, Peccin MS, Almeida GJM, Lira Neto OdA, Queiroz AAB, Navarro RD. Cemented, cementless or hybrid fixation options in total knee arthroplasty for osteoarthritis and other non-traumatic diseases. Cochrane Database Syst Rev. 2012;10:CD006193.10.1002/14651858.CD006193.pub2 ↗
12. Beall DP, Datir A, D’Souza SL, D’Souza LS, Gunda D, Morelli J, et al. Percutaneous treatment of insufficiency fractures. Skelet Radiol. 2010;39:117–30.10.1007/s00256-009-0722-x ↗
13. Driscoll M, Blyum L. The presence of physiological stress shielding in the degenerative cycle of musculoskeletal disorders. J Bodyw Mov Therapies. 2011;15:335–42.10.1016/j.jbmt.2010.05.002 ↗
14. Garg A, Walker PS. The effect of the interface on the bone stresses beneath tibial components. J Biomech. 1986;19:957–67.10.1016/0021-9290(86)90113-2 ↗
15. Lewin S, Forsth P, Persson C. Low-Modulus PMMA Has the potential to reduce stresses on end plates after cement discoplasty. J Funct Biomater. 2022;13:18.10.3390/jfb13010018 ↗
16. Menken LG, Fleuriscar J, Weiner T, Berliner ZP, Rodriguez JA. Aseptic tibial implant loosening after total knee arthroplasty: preventable? J Am Acad Orthop Surg. 2021;29:326–30.10.5435/JAAOS-D-20-00452 ↗
17. Miller MA, Goodheart JR, Izant TH, Rimnac CM, Cleary RJ, Mann KA. Loss of cement-bone interlock in retrieved tibial components from total knee arthroplasties. Clin Orthop Relat Res. 2014;472:304–13.10.1007/s11999-013-3248-4 ↗
18. Mattila RH, Laurila P, Rekola J, Gunn J, Lassila LVJ, Mantyla T, et al. Bone attachment to glass-fibre-reinforced composite implant with porous surface. Acta Biomater. 2009;5:1639–46.10.1016/j.actbio.2009.01.020 ↗
19. Qiu Z-Y, Tao C-S, Cui H, Wang C-M, Cui F-Z. High-strength mineralized collagen artificial bone. Front Mater Sci. 2014;8:53–62.10.1007/s11706-014-0237-9 ↗
20. Kelly MP, Illgen RL, Chen AE, Nam D. Trends in the use of high-viscosity cement in patients undergoing primary total knee arthroplasty in the United States. J Arthroplast. 2018;33:3460–4.10.1016/j.arth.2018.07.007 ↗
21. Hampton CB, Berliner ZP, Nguyen JT, Mendez L, Smith SS, Joseph AD, et al. Aseptic loosening at the tibia in total knee arthroplasty: a function of cement mantle quality? J Arthroplast. 2020;35:S190–S196.10.1016/j.arth.2020.02.028 ↗
22. Ritter J, Hubert J, Kniep I, Beil FT, Rolvien T. Pueschel K. Pulmonary cement embolism is frequently observed but not a contributing factor for death in patients with cemented total hip and knee arthroplasty: a postmortem study. Int Orthop. 2022;46:1225–32.10.1007/s00264-022-05381-6 ↗
23. Liao SS, Guan K, Cui FZ, Shi SS, Sun TS. Lumbar spinal fusion with a mineralized collagen matrix and rhBMP-2 in a rabbit model. Spine. 2003;28:1954–60.10.1097/01.BRS.0000083240.13332.F6 ↗