journal article·2026-01-29Open access

Efficacy and safety of a novel ab interno supraciliary HA-Mg biodegradable glaucoma drainage plate implantation in rabbit eyes

Yujie Rao, Minghe Xiao, Wangdu Luo, Kevin Feng, Junlong Yu, Yi Chen, Xiaomin Zhu, Shicui Xu, Shuang Yuan, Hong Liu, Cindy Hutnik, Yong Wang, Xiangji Li, Lin Xie

Abstract

The uveoscleral outflow pathway is one of the important pathways for aqueous humor outflow. Implanting ab interno glaucoma drainage devices through this pathway does not require conjunctival filtering bleb formation, thereby avoiding bleb-related complications. However, permanent drainage devices can easily cause damage to the corneal endothelium. We hypothesize that a novel ab interno supraciliary HA-Mg biodegradable glaucoma drainage plate through the uveoscleral pathway can reduce corneal endothelial cell damage, demonstrate an IOP-lowering effect, and form and maintain a physiological aqueous outflow pathway after complete degradation and absorption. Sixteen New Zealand white rabbits were randomly assigned to three groups: HA-Mg drainage plate group (10 right eyes), trabeculectomy group (6 right eyes), and control group (16 left eyes). Results showed that the intraocular pressure (IOP) in the ab interno plate group was significantly lower than in the other two groups within the first 20 weeks after surgery (P < 0.0001). After 21 weeks, the IOP in the ab interno plate group gradually returned to the levels of the other two groups. Within 5 months after surgery, the plate was completely degraded and absorbed, the aqueous humor drainage pathway extended to the supraciliary space at the anterior chamber angle, and a water sac-like gap formed above the ciliary body. At the 6th month postoperatively, the number of corneal endothelial cells in the ab interno supraciliary HA-Mg drainage plate group was 2446.0 ± 104.3, and in the control group was 2391.67 ± 49.6, revealing no statistically significant difference (t = -1.611, P = 0.168). In summary, the HA-Mg biodegradable glaucoma drainage plate placement in rabbits was well fixed in the supraciliary space. After 5 months of implantation, the internal drainage plate was completely absorbed, and the implantation procedure and degradation process did not cause damage to the corneal endothelial cells. Compared with the trabeculectomy group, the ab interno plate group maintained a significantly lower IOP for a longer period in this normotensive rabbit model. Although an aqueous humor drainage channel was formed after degradation, the IOP gradually returned to the levels of the control group.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Glaucoma and retinal disorders · Corneal Surgery and Treatments · Retinal and Macular Surgery

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Quigley HA, Broman AT. The number of people with glaucoma worldwide in 2010 and 2020. Br J Ophthalmol. 2006;90:262–7.10.1136/bjo.2005.081224 ↗
2. Dada T, Midha N, Shah P, Sidhu T, Angmo D, Sihota R. Innovations in glaucoma surgery from Dr. Rajendra Prasad Centre for Ophthalmic Sciences. Indian J Ophthalmol. 2017;65:103–8.10.4103/ijo.IJO_865_16 ↗
3. Tham YC, Li X, Wong TY, Quigley HA, Aung T, Cheng CY. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology. 2014;121:2081–90.10.1016/j.ophtha.2014.05.013 ↗
4. European Glaucoma Society Terminology and Guidelines for Glaucoma, 5th ed. Br J Ophthalmol. 2021;105:1–169.10.1136/bjophthalmol-2021-egsguidelines ↗
5. Toris CB, Yablonski ME, Wang YL, Camras CB. Aqueous humor dynamics in the aging human eye. Am J Ophthalmol. 1999;127:407–12.10.1016/S0002-9394(98)00436-X ↗
6. Weinreb RN, Toris CB, Gabelt BT, Lindsey JD, Kaufman PL. Effects of prostaglandins on the aqueous humor outflow pathways. Surv Ophthalmol. 2002;47:S53–64.10.1016/S0039-6257(02)00306-5 ↗
7. Gigon A, Shaarawy T. The suprachoroidal route in glaucoma surgery. J Curr Glaucoma Pract. 2016;10:13–20.10.5005/jp-journals-10008-1197 ↗
8. Bill A, Phillips CI. Uveoscleral drainage of aqueous humour in human eyes. Exp Eye Res. 1971;12:275–81.10.1016/0014-4835(71)90149-7 ↗
9. Weinreb RN. Uveoscleral outflow: the other outflow pathway. J Glaucoma. 2000;9:343–5.10.1097/00061198-200010000-00001 ↗
10. Xiangji L, Xiangge H, Xiaomin Z, Jin J, Wei W, Lin X. Classification and progress of glaucoma surgery. Int Rev Ophthalmol. 2021;45:273–9.
11. Tanito M, Chihara E. Safety and effectiveness of gold glaucoma micro shunt for reducing intraocular pressure in Japanese patients with open angle glaucoma. Jpn J Ophthalmol. 2017;61:388–94.10.1007/s10384-017-0520-2 ↗
12. Vold S, Ahmed IIK, Craven ER, Mattox C, Stamper R, Packer M, et al. Two-year COMPASS trial results: supraciliary microstenting with phacoemulsification in patients with open-angle glaucoma and cataracts. Ophthalmology. 2016;123:2103–12.10.1016/j.ophtha.2016.06.032 ↗
13. Myers JS, Masood I, Hornbeak DM, Belda JI, Auffarth G, Jünemann A, et al. Prospective evaluation of two iStent® Trabecular Stents, One iStent Supra® suprachoroidal stent, and postoperative prostaglandin in refractory glaucoma: 4-year outcomes. Adv Ther. 2018;35:395–407.10.1007/s12325-018-0666-4 ↗
14. Oatts JT, Zhang Z, Tseng H, Shields MB, Sinard JH, Loewen NA. In vitro and in vivo comparison of two suprachoroidal shunts. Invest Ophthalmol Vis Sci. 2013;54:5416–23.10.1167/iovs.13-11853 ↗
15. Fili S, Wölfelschneider P, Kohlhaas M. The STARflo glaucoma implant: preliminary 12 months results. Graefes Arch Clin Exp Ophthalmol. 2018;256:773–81.10.1007/s00417-018-3916-x ↗
16. Vieira L, Noronha M, Lemos V, Reina M, Gomes T. Anterior segment optical coherence tomography imaging of filtering blebs after deep sclerectomy with Esnoper-Clip implant: one-year follow-up. J Curr Glaucoma Pract. 2014;8:91–5.10.5005/jp-journals-10008-1169 ↗
17. Figus M, Posarelli C, Passani A, Albert TG, Oddone F, Sframeli AT, et al. The supraciliary space as a suitable pathway for glaucoma surgery: Ho-hum or home run?. Surv Ophthalmol. 2017;62:828–37.10.1016/j.survophthal.2017.05.002 ↗
18. García-Feijoo J, Rau M, Grisanti S, Grisanti S, Höh H, Erb C, et al. Supraciliary micro-stent implantation for open-angle glaucoma failing topical therapy: 1-year results of a multicenter study. Am J Ophthalmol. 2015;159:1075–81.10.1016/j.ajo.2015.02.018 ↗
19. Lass JH, Benetz BA, He J, Hamilton C, Von Tress M, Dickerson J, et al. Corneal endothelial cell loss and morphometric changes 5 years after phacoemulsification with or without CyPass Micro-Stent. Am J Ophthalmol. 2019;208:211–8.10.1016/j.ajo.2019.07.016 ↗
20. Alcon. Alcon announces voluntary global market withdrawal of CyPass Micro-Stent for surgical glaucoma. Media release. Basel, Switzerland: Alcon. 2018.
21. Li X, Filek R, Zhu X, Gao H, Qiao L, Liu H, et al. Bio-modulation of scaring Glaucoma Filtration Surgery using a novel application of coated mamagnesium. J Magnes Alloy. 2021;9:883–94.10.1016/j.jma.2020.02.025 ↗
22. Cai M, Luo W, Feng K, Chen Y, Yi L, Zhu X, et al. Intraocular pressure control efficacy and safety of HA-Mg glaucoma drainage plate implantation in the anterior chamber of rabbit eyes. J Mater Sci Mater Med. 2024;35:37.10.1007/s10856-024-06806-x ↗
23. Chen Y, Lin Y, Luo W, Gao H, Hu Y, Qiao L, et al. Biodegradation and biocompatibility of calcium phosphate-coated magnesium in eye environment,in vitro and in vivo. J Magnes Alloy. 2025;13:3081–95.10.1016/j.jma.2023.11.006 ↗
24. Chiang B, Jung JH, Prausnitz MR. The suprachoroidal space as a route of administration to the posterior segment of the eye. Adv Drug Deliv Rev. 2018;126:58–66.10.1016/j.addr.2018.03.001 ↗
25. Die Cyklodialyse, eine neue Glaukomoperation. Dtsch Medizinische Wochenschr. 1905;31:824–6.10.1055/s-0029-1188143 ↗
26. Emami-Naeini P, Yiu G. Medical and surgical applications for the suprachoroidal space. Int Ophthalmol Clin. 2019;59:195–207.10.1097/IIO.0000000000000251 ↗
27. Gao, H, Chen, Y, Chen, X, Huang, L, Yao, H, Zhu, X, et al. In vitro and in vivo studies on bioactive hydroxyapatite-coated magnesium for glaucoma drainage implant. J Magnesium Alloys. 2025;13:442–55.10.1016/j.jma.2023.09.033 ↗
28. Denis P, Hirneiß C, Durr GM, Reddy KP, Kamarthy A, Calvo E, et al. Two-year outcomes of the MINIject drainage system for uncontrolled glaucoma from the STAR-I first-in-human trial. Br J Ophthalmol. 2022;106:65–70.10.1136/bjophthalmol-2020-316888 ↗