Characterization of soft tissue-mimicking materials for ultrasound training phantoms
Source abstract
Abstract
Tissue-mimicking materials are essential for developing realistic ultrasound phantoms in medical training and device calibration. This study systematically evaluates the acoustic and physical properties of 15 materials, including gelatin-based formulations, synthetic gels, and rubbers, to assess their suitability for simulating human soft tissues. The investigation focused on ultrasound propagation speed, attenuation coefficients, and temporal stability, with measurements conducted under controlled conditions to ensure consistency. Results revealed that organic gelatins exhibited propagation speeds (1508-1626 m/s) and attenuation coefficients (0.21-1.10 dB/cm) closely aligned with soft tissue benchmarks (1540 m/s and 0.54 dB/cm MHz, respectively), with minimal variations (<5%) over 15 days. However, their susceptibility to dehydration and mold growth necessitates protective measures. Synthetic gels, such as ballistic gel and PVC-Plastisol, demonstrated superior long-term stability but required more complex fabrication processes. Rubbers, while durable, exhibited acoustic properties that deviated significantly from tissue standards, limiting their utility. The study quantitatively highlights trade-offs between material categories: gelatins offer cost-effectiveness and acoustic fidelity for short-term use, whereas synthetic gels provide durability for repeated applications. These findings provide a comprehensive framework for selecting materials tailored to specific phantom requirements, balancing acoustic accuracy, stability, and manufacturability. The work advances the development of high-fidelity, cost-effective phantoms, with implications for improving ultrasound training and diagnostic tool validation. Future research should explore hybrid materials and extended stability assessments to further optimize phantom performance.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Ultrasound Imaging and Elastography · Ultrasound and Hyperthermia Applications · Anatomy and Medical Technology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. Culjat MO, Goldenberg D, Tewari P, Singh RS. A review of tissue substitutes for ultrasound imaging. Elsevier USA. 2010. https://doi.org/10.1016/j.ultrasmedbio.2010.02.012.10.1016/j.ultrasmedbio.2010.02.012 ↗
2. Carovac A, Smajlovic F, Junuzovic D. Application of ultrasound in medicine. Acta Inform Med. 2011;19:168 https://doi.org/10.5455/aim.2011.19.168-171.10.5455/aim.2011.19.168-171 ↗
3. Fohely F, Oglat A, Sabarna K, Shweiki Z, Hamoudeh B, Shalaan R. Fabrication of low-cost realistic three-dimensional static kidney phantom for ultrasound-guided biopsy applications. J Med Ultrasound. 2022;30:36–40. https://doi.org/10.4103/JMU.JMU_181_20.10.4103/JMU.JMU_181_20 ↗
4. Boctor EM, Choti MA, Burdette EC, Webster RJ. Three-dimensional ultrasound-guided robotic needle placement: an experimental evaluation. Int J Med Robot Comput Assist Surg. 2008;4:180–91. https://doi.org/10.1002/rcs.184.10.1002/rcs.184 ↗
5. Servi M, Lo Picolo R, Dalle Mura F, Mencarelli M, Puggelli L, Facchini F, et al. Advanced physical simulator for pediatric minimally invasive thoracoscopy training in the treatment of pulmonary sequestration. Comput Biol Med. 2025;188 https://doi.org/10.1016/j.compbiomed.2025.109847.10.1016/j.compbiomed.2025.109847 ↗
6. Puggelli L, Mencarelli M, Serio P, Furferi R, Amoretti F, & Volpe Y. Development, implementation, and evaluation of a 3D-printed high-fidelity pediatric mannequin with expected hard-to-intubate airway, Eng Rep. 2024.10.1002/eng2.12975 ↗
7. Mencarelli M, Puggelli L, Virga A, Furferi R, Volpe Y. Acoustic velocity and stability of tissue-mimicking echogenic materials for ultrasound training phantoms. J Mater Sci. 2024;59:6509–24. https://doi.org/10.1007/s10853-024-09610-8.10.1007/s10853-024-09610-8 ↗
8. García-Carpintero E, Naredo E, Vélez-Vélez E, Fuensalida G, Ortiz-Miluy G & Gómez-Moreno C. Phantoms for ultrasound-guided vascular access cannulation training: a narrative review, 2023. Soc Romana Ultrason Med Biol. https://doi.org/10.11152/mu-3711.10.11152/mu-3711 ↗
9. Rocha A, García Peñalvo FJ, Dias GP, Gonçalves R. Study of the echogenic capacity of the materials. in: 18th Iberian Conference on Information Systems and Technologies (CISTI), Information and Technology Management Association (ITMA), 2023.
10. Armstrong SA, Jafary R, Forsythe JS, Gregory SD. Tissue-mimicking materials for ultrasound-guided needle intervention phantoms: a comprehensive review. Elsevier Inc. 2023. https://doi.org/10.1016/j.ultrasmedbio.2022.07.016.10.1016/j.ultrasmedbio.2022.07.016 ↗
11. Maggi LE, von Kruger MA, Pereira WCA, Monteiro EEC. Development of silicon-based materials for ultrasound biological phantoms. in: 2009 IEEE International Ultrasonics Symposium, IEEE, 2009.10.1109/ULTSYM.2009.5441472 ↗
12. Leonov D, Kodenko M, Leichenco D, Nasibullina A, Kulberg N. Design and validation of a phantom for transcranial ultrasonography. Int J Comput Assist Radio Surg. 2022;17:1579–88. https://doi.org/10.1007/s11548-022-02614-2.10.1007/s11548-022-02614-2 ↗
13. Leong SS, Wong J, Shah M, Vijayananthan A, Jalalonmuhali M, Sharif N, et al. Stiffness and anisotropy effect on shear wave elastography: a phantom and in vivo renal study. Ultrasound Med Biol. 2020;46:34–45. https://doi.org/10.1016/j.ultrasmedbio.2019.08.011.10.1016/j.ultrasmedbio.2019.08.011 ↗
14. Nattagh K, Siauw T, Pouliot J, Hsu IC, Cunha JA. A training phantom for ultrasound-guided needle insertion and suturing. Brachytherapy. 2014;13:413–9. https://doi.org/10.1016/j.brachy.2014.01.003.10.1016/j.brachy.2014.01.003 ↗
15. Hasson AM, Patel RD, Sissoko CA, Brattain L, Dion GR. 3D-printed neck phantoms with detailed anatomy for ultrasound-guided procedure and device testing. Laryngoscope Investig Otolaryngol 9:2024, https://doi.org/10.1002/lio2.1309.10.1002/lio2.1309 ↗
16. Baba M, Matsumoto K, Yamasaki N, Shindo H, Yano H, Matsumoto M, et al. Development of a tailored thyroid gland phantom for fine-needle aspiration cytology by three-dimensional printing. J Surg Educ. 2017;74:1039–46. https://doi.org/10.1016/j.jsurg.2017.05.012.10.1016/j.jsurg.2017.05.012 ↗
17. Earle M, De Portu G, & Devos E. Agar ultrasound phantoms for low-cost training without refrigeration. in: African Journal of Emergency Medicine, African Federation for Emergency Medicine 2016:18–23. https://doi.org/10.1016/j.afjem.2015.09.003.10.1016/j.afjem.2015.09.003 ↗
18. Burlew MM, Madsen EL, Zagzebski JA, Banjavic RA, Sum SW. A new ultrasound tissue-equivalent material. Radiat Phys. 1980;134:517–20.
19. Inglis S, Ramnarine KV, Plevris JN, McDicken WN. An anthropomorphic tissue-mimicking phantom of the oesophagus for endoscopic ultrasound. Ultrasound Med Biol. 2006;32:249–59. https://doi.org/10.1016/j.ultrasmedbio.2005.10.005.10.1016/j.ultrasmedbio.2005.10.005 ↗
20. Cannon LM, Fagan AJ, Browne JE. Novel tissue mimicking materials for high frequency breast ultrasound phantoms. Ultrasound Med Biol. 2011;37:122–35. https://doi.org/10.1016/j.ultrasmedbio.2010.10.005.10.1016/j.ultrasmedbio.2010.10.005 ↗
21. Brewin MP, Pike LC, Rowland DE, Birch MJ. The acoustic properties, centered on 20 MHZ, of an IEC agar-based tissue-mimicking material and its temperature, frequency and age dependence. Ultrasound Med Biol. 2008;34:1292–306. https://doi.org/10.1016/j.ultrasmedbio.2007.12.017.10.1016/j.ultrasmedbio.2007.12.017 ↗
22. Young Y, Shahedi M, Dormer JD, Johnson BA, Gahan J, Fei B. A low-cost PVC-based dual-modality kidney phantom. in: PMC 2023, SPIE-Intl Soc Optical Eng, 2022, p. 98. https://doi.org/10.1117/12.2611592.10.1117/12.2611592 ↗
23. De Matheo L, Geremia J, Calas MJG, Costa-Jùnior JFS, da Silva FFF, von Krüger MA, et al. PVCP-based anthropomorphic breast phantoms containing structures similar to lactiferous ducts for ultrasound imaging: A comparison with human breasts. Ultrasonics. 2018;90:144–52. https://doi.org/10.1016/j.ultras.2018.06.013.10.1016/j.ultras.2018.06.013 ↗
24. Zell K, Sperl JI, Vogel MW, Niessner, R, Haisch C. Acoustical properties of selected tissue phantom materials for ultrasound imaging. Phys Med Biol 52:2007 https://doi.org/10.1088/0031-9155/52/20/N02.10.1088/0031-9155/52/20/N02 ↗
25. Hariyanto AP, Budiarti NT, Suprijanto, Ng KH, Haryanto F, Endarko. Evaluation of physical properties and image of polyvinyl chloride as breast tissue equivalence for dual-modality (mammography and ultrasound). Phys Eng Sci Med. 2023;46:1175–85. https://doi.org/10.1007/s13246-023-01283-y.10.1007/s13246-023-01283-y ↗
26. Li W, Belmont B, Greve JM, Manders AB, Downey BC, Zhang X, et al. Polyvinyl chloride as a multimodal tissue-mimicking material with tuned mechanical and medical imaging properties. Med Phys. 2016;43:5577–92. https://doi.org/10.1118/1.4962649.10.1118/1.4962649 ↗
27. Cortela G, Benech N, Pereira WCA, Negreira C. Characterization of acoustical properties of a phantom for soft tissues (PVCP and Graphite Powder) in the range 20–45 °C, in Physics Procedia, Elsevier, 2015:179–82. https://doi.org/10.1016/j.phpro.2015.08.107.10.1016/j.phpro.2015.08.107 ↗
28. Ceh D, Peters TM, Chen ECS. Acoustic characterization of polyvinyl chloride and self-healing silicone as phantom materials. In: Medical Imaging 2015: Physics of Medical Imaging, SPIE, 2015:94123G. https://doi.org/10.1117/12.2081449.10.1117/12.2081449 ↗
29. Thouvenot A, Poepping T, Peters TM, Chen ECS. Characterization of various tissue mimicking materials for medical ultrasound imaging. in: SPIE - The International Society for Optical Engineering, SPIE, 2016. https://doi.org/10.1117/12.2218160.10.1117/12.2218160 ↗
30. Sheppard J, Duck FA. Ultrasonic tissue-equivalent materials using inorganic gel mixtures. Br J Radiol. 1982;55:221–31.10.1259/0007-1285-55-657-667 ↗
31. Alves N, kim A, Tan J, Hwang G, Javed T, Neagu B, et al. Cardiac tissue-mimicking ballistic gel phantom for ultrasound imaging in clinical and research applications. Ultrasound Med Biol. 2020;46:2057–69. https://doi.org/10.1016/j.ultrasmedbio.2020.03.011.10.1016/j.ultrasmedbio.2020.03.011 ↗
32. Harrington D, Damon A, Clifton W, Simon L. A unique approach to building a learner-guided ultrasound simulator for central venous access training. Ultrasound Q. 2020;36:275–9. https://doi.org/10.1097/RUQ.0000000000000493.10.1097/RUQ.0000000000000493 ↗
33. Pacioni A, Carbone M, Freschi C, Viglialoro R, Ferrari V, Ferrari M. Patient-specific ultrasound liver phantom: materials and fabrication method. Int J Comput Assist Radio Surg. 2015;10:1065–75. https://doi.org/10.1007/s11548-014-1120-y.10.1007/s11548-014-1120-y ↗
34. Browne JE, Ramnarine KV, Watson AJ, Hoskins PR. Assessment of the acoustic properties of common tissue-mimicking test phantoms. Ultrasound Med Biol. 2003;29:1053–60. https://doi.org/10.1016/S0301-5629(03)00053-X.10.1016/S0301-5629(03)00053-X ↗
35. Cafarelli A, Miloro P, Verbeni A, Carbone M, Menciassi A. Speed of sound in rubber-based materials for ultrasonic phantoms. J Ultrasound. 2016;19:251–6. https://doi.org/10.1007/s40477-016-0204-7.10.1007/s40477-016-0204-7 ↗
36. IEC TS 63081:2019. Ultrasonics — Methods for the characterization of the ultrasonic properties of materials. International Electrotechnical Commission, Geneva, Switzerland, 2019.
37. Zhao B, Basir OA, Mittal GS. Estimation of ultrasound attenuation and dispersion using short time Fourier transform. Ultrasonics. 2005;43:375–81. https://doi.org/10.1016/j.ultras.2004.08.001.10.1016/j.ultras.2004.08.001 ↗
38. Butterworth S. On the theory of filter amplifiers. Exp Wirel Wirel Eng. 1930;7:536–41.
39. Smooth-On: https://www.smooth-on.com/.
40. Feroca: https://feroca.com/.
41. Momentive: https://www.momentive.com/.