journal article·2026-06-13Open access

Comparative hemocompatibility assessment of fibrin/heparin-coated and PMEA-coated flow diverters

Huan Wei, Tomáš Riedel, Zuzana Riedelová, Melanie Wolf, Christian Schlensak, Meltem Avci-Adali

Abstract

Flow diverters play an important role in the endovascular treatment of intracranial aneurysms; however, their use can be associated with thromboembolic complications. Thus, in recent years, flow diverters with surface coatings have been developed to prevent thrombus-related complications. In this study, the hemocompatibility of the flow diverters FRED X with poly(2-methoxyethyl acrylate) (PMEA) coating and the DERIVO 2heal with fibrin/heparin coating, as well as the uncoated DERIVO 2 flow diverter, was evaluated using an in vitro blood circulation model. Using enzyme-linked immunosorbent assay (ELISA), biomarkers of thrombocytes (β-thromboglobulin (β-TG)), coagulation (thrombin-antithrombin complex (TAT)), complement system (SC5b-9), and inflammation (PMN elastase) activation were analyzed. Further analyses comprised thrombogenicity assessment by scanning electron microscopy and measurement of blood cell counts and hemolysis. The uncoated DERIVO 2 flow diverter exhibited increased coagulation and platelet activation, accompanied by enhanced adhesion of platelets to the blood-contacting surfaces. In contrast, both the FRED X and the DERIVO 2-heal flow diverter could effectively reduce the coagulation (TAT) and platelet activation (β-TG) and prevent the adhesion of platelets. Notably, DERIVO 2heal flow diverter induced significantly lower activation of the complement system (SC5b-9) and reduced inflammatory response (PMN elastase) compared to FRED X flow diverter. These findings indicate the improved hemocompatibility of the fibrin/heparin-coated DERIVO 2heal flow diverter and its potential to reduce thromboinflammatory complications.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Trauma, Hemostasis, Coagulopathy, Resuscitation · Blood properties and coagulation · Hemostasis and retained surgical items

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Xu Z. Intracranial aneurysms: pathology, genetics, and molecular mechanisms. Neuromol Med. 2019;21:325–43.10.1007/s12017-019-08537-7 ↗
2. Lv B. Epidemiological trends of subarachnoid hemorrhage at global, regional, and national level: a trend analysis study from 1990 to 2021. Mil Med Res. 2024;11:46.
3. Hughes JD. Estimating the global incidence of aneurysmal subarachnoid hemorrhage: a systematic review for central nervous system vascular lesions and meta-analysis of ruptured aneurysms. World Neurosurg. 2018;115:430–47.e7.10.1016/j.wneu.2018.03.220 ↗
4. Etminan N. Worldwide incidence of aneurysmal subarachnoid hemorrhage according to region, time period, blood pressure, and smoking prevalence in the population: a systematic review and meta-analysis. JAMA Neurol. 2019;76:588–97.10.1001/jamaneurol.2019.0006 ↗
5. Dandy WE. Intracranial aneurysm of the internal carotid artery: cured by operation. Ann Surg. 1938;107:654–9.10.1097/00000658-193805000-00003 ↗
6. Belavadi R. Surgical clipping versus endovascular coiling in the management of intracranial aneurysms. Cureus. 2021;13:20478.
7. Molyneux A. International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet. 2002;360:1267–74.10.1016/S0140-6736(02)11314-6 ↗
8. Seshadhri S. Impact of stents and flow diverters on hemodynamics in idealized aneurysm models. J Biomech Eng. 2011;133:071005.10.1115/1.4004410 ↗
9. Kim S. Computational study of hemodynamic changes induced by overlapping and compacting of stents and flow diverter in cerebral aneurysms. Front Neurol. 2021;12:705841.10.3389/fneur.2021.705841 ↗
10. Alderazi YJ. Flow diverters for intracranial aneurysms. Stroke Res Treat. 2014;2014:415653–12.
11. Arrese I. Flow-diverter devices for intracranial aneurysms: systematic review and meta-analysis. Neurosurgery. 2013;73:193–9.10.1227/01.neu.0000430297.17961.f1 ↗
12. Fiorella D. Very late thrombosis of a pipeline embolization device construct: case report. Neurosurgery. 2010;67:onsE313–onsE314.
13. White TG. Flow diverter surface modifications for aneurysm treatment: A review of the mechanisms and data behind existing technologies. Inter Neuroradiol. 2026;32:109–25.10.1177/15910199231207550 ↗
14. Raikar AS. Surface engineering of bioactive coatings for improved stent hemocompatibility: a comprehensive review. Materials. 2023;16:6940.10.3390/ma16216940 ↗
15. Schumacher AL. Development and evaluation of a nanometer-scale hemocompatible and antithrombotic coating technology platform for commercial intracranial stents and flow diverters. ACS Appl Nano Mater. 2018;1:344–54.10.1021/acsanm.7b00192 ↗
16. Starke RM. Preclinical safety and efficacy evaluation of the Pipeline Vantage Embolization Device with Shield Technology. J Neurointerv Surg. 2020;12:981–6.10.1136/neurintsurg-2020-016043 ↗
17. Bilgin C. Phenox HPC and Phenox flow modulation devices for the endovascular treatment of intracranial aneurysms: a systematic review and meta-analysis. J Neurointerv Surg. 2024;16:706–14.10.1136/jnis-2023-020514 ↗
18. Abbas R. First United States multicenter experience with the new-generation FRED X surface-modified flow diversion stent: feasibility, safety, and short-term efficacy. J Neurosurg. 2024;140:1054–63.10.3171/2023.7.JNS23966 ↗
19. Yoshizawa K. Poly(2-methoxyethyl acrylate) (PMEA) improves the thromboresistance of FRED flow diverters: a thrombogenic evaluation of flow diverters with human blood under flow conditions. J Neurointerv Surg. 2023;15:1001–6.10.1136/jnis-2022-019248 ↗
20. Tanaka M. Design of biocompatible and biodegradable polymers based on intermediate water concept. Polym J. 2015;47:114–21.10.1038/pj.2014.129 ↗
21. Muhl-Benninghaus R. Vascular response on a novel fibrin-based coated flow diverter. Cardiovasc Interv Radio. 2022;45:236–43.10.1007/s00270-021-03007-9 ↗
22. Girbas MG. Comparison of the hemocompatibility of neurovascular flow diverters with anti-thrombogenic coatings. J Sci Adv Mater Devices. 2024;9:100666.10.1016/j.jsamd.2023.100666 ↗
23. Filova E. Improved adhesion and differentiation of endothelial cells on surface-attached fibrin structures containing extracellular matrix proteins. J Biomed Mater Res A. 2014;102:698–712.10.1002/jbm.a.34733 ↗
24. Sinn S. A novel in vitro model for preclinical testing of the hemocompatibility of intravascular stents according to ISO 10993-4. J Mater Sci Mater Med. 2011;22:1521–8.10.1007/s10856-011-4335-2 ↗
25. Kizhakkedathu JN, Conway EM. Biomaterial and cellular implants: foreign surfaces where immunity and coagulation meet. Blood. 2022;139:1987–98.10.1182/blood.2020007209 ↗
26. Schmaier AH. The contact activation and kallikrein/kinin systems: pathophysiologic and physiologic activities. J Thromb Haemost. 2016;14:28–39.10.1111/jth.13194 ↗
27. Maas C, Oschatz C, Renne T. The plasma contact system 2.0. Semin Thromb Hemost. 2011;37:375–81.10.1055/s-0031-1276586 ↗
28. Irmscher S. Kallikrein Cleaves C3 and Activates Complement. J Innate Immun. 2018;10:94–105.10.1159/000484257 ↗
29. Hoffman M, Monroe DM. 3rd, A cell-based model of hemostasis. Thromb Haemost. 2001;85:958–65.10.1055/s-0037-1615947 ↗
30. Manivasagam VK. Surface modification strategies to improve titanium hemocompatibility: a comprehensive review. Mater Adv. 2021;2:5824–42.10.1039/D1MA00367D ↗
31. Piano M. Long-term follow-up of the Derivo® Embolization Device (DED®) for intracranial aneurysms: the Italian Multicentric Registry. J Neurosurgical Sci. 2021;65:361–8.
32. Trivelato FP. Derivo embolization device for the treatment of intracranial aneurysms: a multicenter study of 183 aneurysms. Stroke. 2019;50:2351–8.10.1161/STROKEAHA.119.025407 ↗
33. Taschner CA. Derivo embolization device in the treatment of unruptured intracranial aneurysms: a prospective multicenter study. J NeuroInterventional Surg. 2021;13:541–6.10.1136/neurintsurg-2020-016303 ↗
34. Goertz L. Improved occlusion rate of intracranial aneurysms treated with the Derivo embolization device: one-year clinical and angiographic follow-up in a multicenter study. World Neurosurg. 2019;126:e1503–e1509.10.1016/j.wneu.2019.03.137 ↗
35. Schwab R. The DERIVO 2 heal embolization device in the treatment of ruptured and unruptured intracranial aneurysms: a retrospective multicenter study. Clin Neuroradiol. 2025;35:25–34.10.1007/s00062-024-01446-8 ↗
36. Lourenço GC. Endovascular treatment of intracranial aneurysms using the Derivo Embolization Device: a multicenter experience. J Neurointerv Surg. 2023;15(8):776–780. https://doi.org/10.1136/neurintsurg-2022-01864810.1136/neurintsurg-2022-018648 ↗
37. Thormann M, The DERIVO® 2 Embolization Device in the treatment of ruptured and unruptured intracranial aneurysms: a multicenter analysis. Int Neuroradiol. 2024;30(5):672–678.10.1177/15910199221142643 ↗
38. Uysal A. Initial experience with the derivo 2-heal flow diverter under standard or reduced-dose single antiplatelet therapy. Am J Neuroradiol. 2024;45:1038–43.10.3174/ajnr.A8292 ↗
39. Roy JM. Comparative analysis of safety and efficacy of flow diversion with and without surface modification technology, FRED-X, FRED, PED shield and PED in 386 patients: A single center experience with systematic review and network meta-analysis. J Neurological Sci. 2025;468:123336.10.1016/j.jns.2024.123336 ↗
40. Waqas M. Flow redirection endoluminal device (FRED) for treatment of intracranial aneurysms: a systematic review. Int Neuroradiol. 2022;28:347–57.10.1177/15910199211027991 ↗
41. Mortezaei, A. FRED X flow diversion stent for intracranial aneurysms: a systematic review and meta-analysis. Neuroradiology 2025. https://doi.org/10.1007/s00234-025-03755-2. Epub ahead of print. PMID: 4097096010.1007/s00234-025-03755-2 ↗
42. Swystun LL, Liaw PC. The role of leukocytes in thrombosis. Blood. 2016;128:753–62.10.1182/blood-2016-05-718114 ↗
43. Kaplan O. Low-thrombogenic fibrin-heparin coating promotes in vitro endothelialization. J Biomed Mater Res Part A. 2017;105:2995–3005.10.1002/jbm.a.36152 ↗