Influence of fluoride and chloride on corrosion behavior of NiTi orthodontic wires
Source abstract
Abstract
The influence of fluoride and chloride ions on the corrosion behavior of nearly equiatomic nickel-titanium orthodontic wires was studied using conventional electrochemical measurement methods, including corrosion potential, potentiodynamic and cyclic potentiodynamic polarization measurements. In addition, scanning electron microscopy was employed to observe the surface morphology before and after the test. All the electrochemical parameters are analyzed based on the sample standard deviations. The results indicated that NiTi alloy is primarily susceptible to localized corrosion when exposed to a solution containing chloride, while it is susceptible to general corrosion when subjected to a solution containing fluoride. Furthermore, the synergistic interaction of fluoride and chloride on corrosion of NiTi alloy is associated with their respective molar concentrations.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Shape Memory Alloy Transformations · Corrosion Behavior and Inhibition · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. A summary of recent research on the nitinol alloys and their potential application in ocean engineering10.1016/0029-8018(68)90019-X ↗
2. Biocorrosion and cytocompatibility assessment of NiTi shape memory alloys10.1016/j.scriptamat.2003.09.028 ↗
3. Corrosion resistance tests on NiTi shape memory alloy10.1016/0142-9612(95)00352-5 ↗
4. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys
5. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material
6. Cytotoxic, allergic and genotoxic activity of a nickel–titanium alloy10.1016/S0142-9612(97)00041-0 ↗
7. A study on the electrodeposition of tantalum on NiTi alloy in an ionic liquid and corrosion behaviour of the coated alloy10.1016/j.elecom.2005.06.007 ↗
8. Corrosion and biocompatibility of orthodontic wires10.1023/A:1008953412622 ↗
9. Relevant aspects in the clinical applications of NiTi shape memory alloys10.1007/BF00122008 ↗
10. Interactions of orthopaedic metals with an immortalized rat osteoblast cell line10.1016/0142-9612(96)88681-9 ↗
11. Influence of fluoridated mouthwashes on corrosion resistance of orthodontics wires10.1016/j.biomaterials.2003.11.042 ↗
12. Nickel, chromium, cobalt dental alloys and allergic reactions: an overview10.1016/0142-9612(89)90060-4 ↗
13. Allergic reaction to orthodontic wire: report of case10.14219/jada.archive.1989.0174 ↗
14. Stress corrosion cracking of NiTi in artificial saliva10.1016/j.dental.2006.01.001 ↗
15. Nitinol arch wire in a simulated oral environment: changes in mechanical properties10.1016/0889-5406(88)90080-7 ↗
16. Degradation and fracture of Ni–Ti superelastic wire in an oral cavity10.1016/S0142-9612(00)00414-2 ↗
17. Examination of Chinese NiTi wire by a combined clinical and laboratory approach10.1093/ejo/13.5.386 ↗
18. In vitro corrosion resistance of orthodontic super stainless steel wire10.1149/1.1497983 ↗
19. Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys10.1016/S0142-9612(01)00328-3 ↗
20. Ion release from NiTi orthodontic wires in artificial saliva with various acidities10.1016/S0142-9612(03)00188-1 ↗
21. Corrosion behavior of nitinol wires in body fluid environments10.1002/jbm.a.10099 ↗
22. Measurement and evaluation of galvanic corrosion between titanium/Ti6A14V implants and dental alloys by electrochemical techniques and auger spectrometry10.1016/S0142-9612(98)00248-8 ↗
23. Localized corrosion behaviour in simulated human body fluids of commercial Ni–Ti orthodontic wires10.1016/S0142-9612(98)90233-2 ↗
24. Surface changes induced by fluoride prophylactic agents on titanium-based orthodontic wires10.1016/S0889-5406(03)00197-5 ↗
25. Electrochemical and cytocompatibility assessment of NiTiNOL memory shape alloy for orthodontic use10.1016/S1389-0344(02)00041-2 ↗
26. Corrosion of gold and amalgam placed in contact with each other10.1177/00220345630420051301 ↗
27. Influence of fluoride on titanium in an acidic environment measured by polarization resistance technique10.1002/jab.770060409 ↗
28. Evaluation of the effect of fluoride-containing acetic acid on NiTi wires10.1002/jbm.b.30129 ↗
29. Electrochemical release testing of nickel–titanium orthodontic wires in artificial saliva using thin layer activation10.1016/j.actbio.2005.07.008 ↗
30. Susceptibility to delayed fracture of alpha–beta titanium alloy in fluoride solutions10.1016/j.corsci.2004.08.007 ↗
31. Hydrogen embrittlement of work-hardened Ni–Ti alloy in fluoride solutions10.1016/j.biomaterials.2004.02.009 ↗
32. Effect of pH and temperature on orthodontic NiTi wires immersed in acidic fluoride solution10.1002/jbm.b.30505 ↗
33. Cytotoxic and antibacterial effects of orthodontic appliances
34. Effect of pH, temperature and Cl− concentration on electrochemical behavior of NiTi shape memory alloy in artificial saliva10.1007/s10856-006-0178-7 ↗
35. ASTM · 1994 · vol. 03.02 · 48
36. Delayed fracture of beta titanium wire in fluoride aqueous solutions10.1016/S0142-9612(02)00642-7 ↗
37. Effect of electrolytic ZrO2 coatings on the breakdown potential of NiTi wires used as endovascular implants10.1016/j.matlet.2004.11.015 ↗
38. Electrochemical and surface characterization of a nickel–titanium alloy10.1016/S0142-9612(97)00210-X ↗
39. Corrosion behavior of titanium nitride coated Ni–Ti shape memory surgical alloy10.1016/S0142-9612(00)00368-9 ↗
40. Corrosion behavior of AISI 316L stainless steel surface-modified with NiTi10.1016/j.surfcoat.2005.09.009 ↗
41. Surface characterizations and corrosion resistance of nickel–titanium orthodontic archwires in artificial saliva of various degrees of acidity10.1002/jbm.a.30340 ↗
42. Introduction to surface reactions: electrochemical basis of corrosion
43. Effect of chemical etching and aging in boiling water on the corrosion resistance of nitinol wires with lack of oxide resulting from the manufacturing process10.1002/jbm.b.10017 ↗