Loss of mechanical properties in vivo and bone–implant interface strength of AZ31B magnesium alloy screws with Si-containing coating
Source abstract
Abstract
In this study the loss of mechanical properties and the interface strength of coated AZ31B magnesium alloy (a magnesium-aluminum alloy) screws with surrounding host tissues were investigated and compared with non-coated AZ31B, degradable polymer and biostable titanium alloy screws in a rabbit animal model after 1, 4, 12 and 21weeks of implantation. The interface strength was evaluated in terms of the extraction torque required to back out the screws. The loss of mechanical properties over time was indicated by one-point bending load loss of the screws after these were extracted at different times. AZ31B samples with a silicon-containing coating had a decreased degradation rate and improved biological properties. The extraction torque of Ti6Al4V, poly-l-lactide (PLLA) and coated AZ31B increased significantly from 1week to 4weeks post-implantation, indicating a rapid osteosynthesis process over 3weeks. The extraction torque of coated AZ31B increased with implantation time, and was higher than that of PLLA after 4weeks of implantation, equalling that of Ti6Al4V at 12weeks and was higher at 21weeks. The bending loads of non-coated AZ31B and PLLA screws degraded sharply after implantation, and that of coated AZ31B degraded more slowly. The biodegradation mechanism, the coating to control the degradation rate and the bioactivity of magnesium alloys influencing the mechanical properties loss over time and bone-implant interface strength are discussed in this study and it is concluded that a suitable degradation rate will result in an improvement in the mechanical performance of magnesium alloys, making them more suitable for clinical application.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Aluminum Alloys Composites Properties · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. Magnesium and its alloys as orthopedic biomaterials: a review10.1016/j.biomaterials.2005.10.003 ↗
2. A possible biodegradable magnesium implant material10.1002/adem.200600252 ↗
3. In vitro degradation, hemolysis and MC3T3-E1 cell adhesion of biodegradable Mg–Zn alloy10.1016/j.msec.2009.03.001 ↗
4. Characterization and corrosion studies of fluoride conversion coating on degradable Mg implants10.1016/j.surfcoat.2007.06.035 ↗
5. Control of degradation rate of bioabsorbable magnesium by anodization and steam treatment10.1016/j.msec.2010.06.001 ↗
6. Study on the corrosion resistance of phytic acid conversion coating for magnesium alloys10.1016/j.surfcoat.2006.02.020 ↗
7. Electrodeposition of Ca-P coatings on biodegradable Mg alloy: in vitro biomineralization behavior10.1016/j.actbio.2009.12.020 ↗
8. Surface modifications of magnesium alloys for biomedical applications10.1007/s10439-011-0300-y ↗
9. Study on beta-TCP coated porous Mg as a bone tissue engineering scaffold material
10. Characterization and degradation behavior of AZ31 alloy surface modified by bone-like hydroxyapatite for implant applications10.1016/j.apsusc.2008.09.078 ↗
11. Controlling the biodegradation rate of magnesium using biomimetic apatite coating10.1002/jbm.b.31228 ↗
12. Corrosion protection of biodegradable magnesium implants using anodization10.1016/j.msec.2010.08.019 ↗
13. Evaluation of magnesium ions release, biocorrosion, and hemocompatibility of MAO/PLLA-modified magnesium alloy WE4210.1002/jbm.b.31744 ↗
14. Biocompatibility of fluoride-coated magnesium-calcium alloys with optimized degradation kinetics in a subcutaneous mouse model10.1002/jbm.a.34300 ↗
15. A biodegradable polymer-based coating to control the performance of magnesium alloy orthopaedic implants10.1016/j.biomaterials.2009.11.111 ↗
16. In vitro and in vivo evaluation of the surface bioactivity of a calcium phosphate coated magnesium alloy10.1016/j.biomaterials.2008.12.001 ↗
17. Fluoride treatment and in vitro corrosion behavior of an AZ31B magnesium alloy10.1016/j.msec.2010.03.007 ↗
18. Dynamic behaviors of a Ca–P coated AZ31B magnesium alloy during in vitro and in vivo degradations10.1016/j.mseb.2011.06.005 ↗
19. The nutritional essentiality of silicon10.1111/j.1753-4887.1982.tb05307.x ↗
20. Silicon compatible with the height of human vertebral column10.1385/BTER:95:2:113 ↗
21. The role of silicon in osteoblast-like cell proliferation and apoptosis10.1016/j.actbio.2011.02.023 ↗
22. Silicate bioceramics induce angiogenesis during bone regeneration10.1016/j.actbio.2011.09.008 ↗
23. Electrodeposition of hydroxyapatite coating on AZ91D magnesium alloy for biomaterial application10.1016/j.matlet.2008.02.048 ↗
24. Poly(L-lactide) – a long-term degradation study in-vivo. 2. Physicomechanical behavior of implants10.1016/0142-9612(94)90223-2 ↗
25. Preparation, characterization and biodegradable characteristics of poly(D, L-lactide-co-1,3-trimethylene carbonate)10.1002/(SICI)1097-0126(199704)42:4<373::AID-PI722>3.0.CO;2-U ↗
26. Structure and thermal/mechanical properties of poly(epsilon-caprolactone)-clay blend10.1002/(SICI)1097-4628(19970613)64:11<2211::AID-APP17>3.0.CO;2-6 ↗
27. Bone-implant interface strength and osseointegration: biodegradable magnesium alloy versus standard titanium control10.1016/j.actbio.2010.08.020 ↗
28. Corrosion resistance and surface biocompatibility of a microarc oxidation coating on a Mg–Ca alloy10.1016/j.actbio.2010.11.034 ↗
29. Comparison of degradation behavior and the associated bone response of ZK60 and PLLA in vivo
30. In vivo degradation performance of micro-arc-oxidized magnesium implants: A micro-CT study in rats10.1016/j.actbio.2012.09.017 ↗
31. The role of bone induction of a biodegradable magnesium alloy