journal article·2013-12

In vitro hemocompatibility and vascular endothelial cell functionality on titania nanostructures under static and dynamic conditions for improved coronary stenting applications

C.C. Mohan, K.P. Chennazhi, D. Menon

Acta Biomaterialia· Volume 9· Issue 12
Publisher page

Abstract

The usefulness of nanoscale topography in improving vascular response in vitro was established previously on hydrothermally modified titanium surfaces. To propose this strategy of surface modification for translation onto clinically used metallic stents, it is imperative that the surface should be also hemocompatible: an essential attribute for any blood-contacting device. The present in vitro study focuses on a detailed hemocompatibility evaluation of titania nanostructures created through an alkaline hydrothermal route on metallic Ti stent prototypes. Direct interactions of TiO2 nanocues of various morphologies with whole blood were studied under static conditions as well as using an in vitro circulation model mimicking arterial flow, with respect to a polished Ti control. Nanomodified stent surfaces upon contact with human blood showed negligible hemolysis under constant shear and static conditions. Coagulation profile testing indicated that surface roughness of nanomodified stents induced no alterations in the normal clotting times, with insignificant thrombus formation and minimal inflammatory reaction. Endothelialized nanomodified Ti surfaces were found to inhibit both activation as well as aggregation of platelets compared with the control surface, with the endothelium formed on the nanosurfaces having an increased expression of anti-thrombogenic genes. Such a nanotextured Ti surface, which is anti-thrombogenic and promotes endothelialization, would be a cost-effective alternative to drug-eluting stents or polymer-coated stents for overcoming in-stent restenosis.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Aortic aneurysm repair treatments · Polymer Surface Interaction Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (45)

Show source-provided references
1. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease10.1056/NEJM199408253310802 ↗
2. Palmaz JC. Intravascular Stents in the Last and the Next 10 Years. J Endovsc Threr 2004;11:II-200–II-206.10.1583/04-1363.1 ↗
3. Stenting of nonacute total coronary occlusions: predictors of late angiographic outcome10.1016/S0735-1097(97)00501-9 ↗
4. deMel A, Cousins BG, Seifalian AM. surface modification of biomaterials: a quest for blood compatibility. Int J Biomater 2012;2012:8.
5. Current strategies towards hemocompatible coatings10.1039/b703416b ↗
6. Materials for metallic stents10.1007/s10047-008-0456-x ↗
7. de Oliveira PT, Zalzal SF, Beloti MM, Rosa A L, Nanci A. Enhancement of in vitro osteogenesis on titanium by chemically produced nanotopography. J Biomed Mater Res Part A 2007;80A:554–564.10.1002/jbm.a.30955 ↗
8. Influence of titania nanotopography on human vascular cell functionality and its proliferation in vitro10.1039/C1JM13726C ↗
9. Enhanced endothelial cell functions on rosette nanotube-coated titanium vascular stent
10. The effect of TiO2 nanotubes on endothelial function and smooth muscle proliferation10.1016/j.biomaterials.2008.11.012 ↗
11. Enhanced cellular mobility guided by TiO2 nanotube surfaces10.1021/nl072572o ↗
12. Tsyganova, Maitzb MF, Wieserb E. Blood compatibility of titanium-based coatings prepared by metal plasma immersion ion implantation and deposition. Appl Surf Sci 2004;235:156–63.10.1016/j.apsusc.2004.05.134 ↗
13. Blood compatibility of amorphous titanium oxide films synthesized by ion beam enhanced deposition10.1016/S0142-9612(98)00212-9 ↗
14. Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia10.1161/hc3401.093146 ↗
15. In vivo investigation of blood compatibility of titanium oxide films10.1002/(SICI)1097-4636(199810)42:1<128::AID-JBM16>3.0.CO;2-H ↗
16. Divya Rani VV, Manzoor K, Menon D, Selvamurugan N, Nair SV. The design of novel nanostructures on titanium by solution chemistry for an improved osteoblast response. Nanotechnology 2009;20:195101.10.1088/0957-4484/20/19/195101 ↗
17. Culture of human endothelial cells derived from umbilical veins: identification by morphological and immunologic criteria10.1172/JCI107470 ↗
18. Divya Rani VV, Vinoth KL, Anitha VC, Manzoor K, Menon D, Nair SV. Osteointegration of titanium implant is sensitive to specific nanostructure morphology. Acta Biomater 2012;8:1976–89.10.1016/j.actbio.2012.01.021 ↗
19. Platelet interactions with titanium: modulation of platelet activity by surface topography10.1016/S0142-9612(01)00009-6 ↗
20. Influence of nanoscale surface topography on protein adsorption and cellular response10.1016/j.nantod.2010.01.001 ↗
21. Investigation of the effects of surface chemistry and solution concentration on the conformation of adsorbed proteins using an improved circular dichroism method10.1021/la8036814 ↗
22. Endothelium-dependent effects of statins10.1161/01.ATV.0000063385.12476.A7 ↗
23. The endothelium as a regulator of vascular smooth muscle proliferation
24. Vascular endothelial cells synthesize nitric oxide from L-arginine10.1038/333664a0 ↗
25. Endothelial cell recovery between comparator polymer-based drug-eluting stents10.1016/j.jacc.2008.04.030 ↗
26. Effect of rabbit thrombomodulin on thrombin inhibition by antithrombin in the presence of heparin10.1016/0049-3848(89)90334-4 ↗
27. Vascular endothelin in hypertension10.1016/j.vph.2005.03.004 ↗
28. The surface valence band structure and hemocompatibility of rutile titanium oxide films
29. Thierry B, Merhi Y, Trepanier C, Bi lodcau JL, Yahia LH, Tabrizian M. Blood compatibility of Nitinol compared with stainless steel, In: Proceedings of the Int’l Conference on Shape Memory and Superelastic Technologies SMST-2000 2000;285–290.
30. Adhesion and activation of platelets and polymorphonuclear granulocyte cells at TiO2 surfaces10.1016/S0022-2143(97)90159-1 ↗
31. Blood compatibility of titanium oxides with various crystal structure and element doping10.1177/0885328203017004005 ↗
32. Erythrocytin, a clotting factor from erythrocytes. Its action and purification
33. Shear-induced platelet aggregation can be mediated by vWF release from platelets, as well as by exogenous large or unusually large vWF multimers, requires adenosine diphosphate, and is resistant to aspirin
34. The effect of thrombo-cytopenia on experimental arteriosclerotic lesion formation in rabbits; smooth muscle cell proliferation and re-endothelialization10.1172/JCI108872 ↗
35. The elusive physiologic role of factor XII
36. Initiation of blood coagulation at artificial surfaces10.1111/j.1749-6632.1987.tb33046.x ↗
37. Subacute thrombosis and vascular injury resulting from slotted-tube nitinol and stainless steel stents in a rabbit carotid artery model10.1161/01.CIR.94.7.1733 ↗
38. Blood compatibility of amorphous titanium oxide films synthesized by ion beam enhanced deposition10.1016/S0142-9612(98)00212-9 ↗
39. In vitro hemocompatibility of albumin-heparin multilayer coatings on polyethersulfone prepared by the layer-by-layer technique10.1002/jbm.a.30519 ↗
40. Influence of a layer-by-layer-assembled multilayer of anti-CD34 antibody, vascular endothelial growth factor, and heparin on the endothelialization and anticoagulation of titanium surface10.1002/jbm.a.34392 ↗
41. In vitro blood compatibility of functional group-grafted and heparinimmobilized polyurethanes prepared by plasma glow discharge10.1016/S0142-9612(97)00035-5 ↗
42. Titanate biomaterials with enhanced anti-inflammatory properties10.1002/jbm.a.30961 ↗
43. Retrieved fracture plates: implant and tissue analysis in: implant retrieval: material and biological analysis
44. Characteristics of metals used in implants10.1089/end.1997.11.383 ↗
45. Metal implants and surface reactions10.1016/0020-1383(96)89027-9 ↗