Surface structure and properties of biomedical NiTi shape memory alloy after Fenton’s oxidation
Source abstract
Abstract
Fenton's oxidation is traditionally used to remove inorganic and organic pollutants from water in waster water treatment. It is an advanced oxidation process in which H2O2 is catalytically decomposed by ferrous irons into hydroxyl radicals (*OH) which have a higher oxidation potential (2.8V) than H2O2. In the work reported here, we for the first time use Fenton's oxidation to modify the surface of biomedical NiTi shape memory alloy (SMA). The influences of Fenton's oxidation on the surface microstructure, blood compatibility, leaching of harmful Ni ions and corrosion resistance in simulated body fluids is assessed using scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, inductively coupled plasma mass spectrometry, electrochemical tests, hemolysis analysis and the blood platelet adhesion test. The mechanical stability of the surface titania film produced by Fenton's oxidation as well as their effects on the shape memory behavior of the SMA are studied by bending tests. Our results show that Fenton's oxidation produces a novel nanostructured titania gel film with a graded structure on the NiTi substrate without an intermediate Ni-rich layer that is typical of high-temperature oxidation. Moreover, there is a clear Ni-free zone near the top surface of the titania film. The surface structural changes introduced by Fenton's oxidation improve the electrochemical corrosion resistance and mitigate Ni release. The latter effects are comparable to those observed after oxygen plasma immersion ion implantation reported previously and better than those of high-temperature oxidation. Aging in boiling water improves the crystallinity of the titania film and further reduces Ni leaching. Blood platelet adhesion is remarkably reduced after Fenton's oxidation, suggesting that the treated SMA has improved thrombo resistance. Enhancement of blood compatibility is believed to stem from the improved hemolysis resistance, the surface wettability and the intrinsic electrical characteristics of the titania film. The titania film produced by Fenton's oxidation has good mechanical stability and does not adversely impact the shape memory behavior of NiTi. Our work suggests that Fenton's oxidation is a promising low-temperature, low-cost surface modification method for improving the surface properties of biomedical NiTi SMA.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Magnesium Oxide Properties and Applications · TiO2 Photocatalysis and Solar Cells
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (49)
Show source-provided references
1. An overview of nitinol medical applications10.1016/S0921-5093(99)00294-4 ↗
2. Otsuka · 1998
3. Yahia · 2000
4. Bone modeling and cell–material interface responses induced by nickel–titanium shape memory alloy after periosteal implantation10.1016/S0142-9612(99)00032-0 ↗
5. Localized corrosion behaviour in simulated human body fluids of commercial Ni–Ti orthodontic wires10.1016/S0142-9612(98)90233-2 ↗
6. Electrochemical and surface characterization of a nickel–titanium alloy10.1016/S0142-9612(97)00210-X ↗
7. Initial events in interaction of blood with foreign surfaces10.1002/jbm.820030115 ↗
8. Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants10.1116/1.579461 ↗
9. Sol–gel deposited TiO2 film on NiTi surgical alloy for biocompatibility improvement10.1016/S0040-6090(03)00146-9 ↗
10. Structural and mechanical characterisation of boron and nitrogen implanted NiTi shape memory alloy10.1016/S0257-8972(02)00188-3 ↗
11. Corrosion and wear-corrosion behavior of NiTi modified by plasma source ion implantation10.1016/S0142-9612(03)00271-0 ↗
12. Carbon plasma immersion ion implantation of nickel–titanium shape memory alloys10.1016/j.biomaterials.2004.07.056 ↗
13. Corrosion behavior of phosphorus ion-implanted Ni50.6Ti49.4 shape memory alloy10.1016/S0257-8972(02)00048-8 ↗
14. Corrosion properties of laser surface melted NiTi shape memory alloy10.1016/S1359-6462(01)01182-4 ↗
15. Evaluation of structural characteristics of TiNi/Al2O3/Ti6Al4V composite biomaterial
16. Bioactive immobilization of r-hirudin on CVD-coated metallic implant devices10.1016/S0142-9612(00)00244-1 ↗
17. Gas nitriding of an equiatomic TiNi shape memory alloy. II. Hardness, wear and shape memory ability10.1016/S0257-8972(98)00810-X ↗
18. Calcium phosphate coating of nickel–titanium shape-memory alloys. Coating procedure and adherence of leukocytes and platelets10.1016/S0142-9612(03)00241-2 ↗
19. Study on the formation of an apatite layer on NiTi shape memory alloy using a chemical treatment method10.1016/S0257-8972(03)00733-3 ↗
20. Graded surface structure in chemically polished NiTi shape memory alloy after subsequent NaOH treatment10.1016/j.scriptamat.2005.02.002 ↗
21. Spontaneous formation of bonelike apatite layer on chemically treated titanium metals10.1111/j.1151-2916.1996.tb08561.x ↗
22. Biomimetic hydroxyapatite coating on metal implants10.1111/j.1151-2916.2002.tb00126.x ↗
23. A comparative study of in vitro apatite deposition on heat-, H2O2-, and NaOH-treated titanium surfaces10.1002/1097-4636(200102)54:2<172::AID-JBM3>3.0.CO;2-# ↗
24. Blood compatibility of titanium oxide prepared by ion-beam-enhanced deposition10.1016/S0257-8972(96)02848-4 ↗
25. Blood compatibility of amorphous titanium oxide films synthesized by ion beam enhanced deposition10.1016/S0142-9612(98)00212-9 ↗
26. Characterisation of surface-modified nickel titanium alloys10.1016/S0921-5093(02)00818-3 ↗
27. Surface oxidation of NiTi shape memory alloy10.1016/S0142-9612(02)00244-2 ↗
28. Oxidation behavior of TiNi shape memory alloy at 450–750 degrees10.1016/S0921-5093(03)00287-9 ↗
29. Oxidation behavior of equiatomic TiNi alloy in high temperature air environment10.1016/0921-5093(96)10409-3 ↗
30. Oxidation of a NiTi alloy10.1002/sia.740150602 ↗
31. Porous titania films prepared from interactions of titanium with hydrogen peroxide solution10.1016/S1359-6462(01)01207-6 ↗
32. Improvement of bioactivity of H2O2/TaCl5-treated titanium after subsequent heat treatments10.1002/1097-4636(200010)52:1<171::AID-JBM22>3.0.CO;2-O ↗
33. Platelet adhesion on titanium oxide gels: effect of surface oxidation10.1016/j.biomaterials.2003.10.070 ↗
34. In vivo evaluation of bone-bonding of titanium metal chemically treated with a hydrogen peroxide solution containing tantalum chloride10.1016/S0142-9612(01)00036-9 ↗
35. Surface oxidation of NiTi shape memory alloy in a boiling aqueous solution containing hydrogen peroxide10.1016/j.msea.2005.11.010 ↗
36. A review of classic Fenton’s peroxidation as an advanced oxidation technique10.1016/S0304-3894(02)00282-0 ↗
37. Fenton’s oxidation of MTBE with zero-valent iron10.1016/j.watres.2003.10.003 ↗
38. 1990 · vol. 1
39. Corrosion behavior of titanium nitride coated Ni–Ti shape memory surgical alloy10.1016/S0142-9612(00)00368-9 ↗
40. Dependence of apatite formation on silica gel on its structure: effect of heat treatment10.1111/j.1151-2916.1995.tb08887.x ↗
41. XPS characterization of surface modified Ni–Ti shape memory alloy10.1016/S0921-5093(96)10563-3 ↗
42. Crystallization of anatase from amorphous titania in hot water and in vitro biomineralization10.2109/jcersj.110.78 ↗
43. 1982 · D-36
44. Improvements of anti-corrosion and mechanical properties of NiTi orthopedic materials by acetylene, nitrogen and oxygen plasma immersion ion implantation10.1016/j.nimb.2005.05.030 ↗
45. Antithrombogenic material with diffuse layer
46. Cell adhesion to plasma-treated polymer surfaces10.1016/0032-3861(93)90752-V ↗
47. Nanoporous alkoxy-derived titanium oxide coating: a reactive overlayer for functionalizing titanium surface10.1023/A:1008859131585 ↗
48. Ebert R, Schaldach M. Ceramic as material for cardiovascular device. World Congress on Medical Physics and Biomedical Engineering, Hamburg, 1982; 3: p. 7.
49. Gutmann · 1986